Wear of ultra-high molecular weight polyethylene acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricant

被引:45
作者
Bigsby, RJA
Hardaker, CS
Fisher, J
机构
[1] Department of Mechanical Engineering, University of Leeds, DePuy International Limited, Leeds
关键词
wear; UHMWPE; hip joint simulator; zirconia ceramic; stainless steel;
D O I
10.1243/0954411971534377
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Leeds physiological anatomical (PA) hip joint simulator was developed to apply three axes of loading and a complex three-dimensional motion so that the forces and motions can reproduce exactly the walking cycles defined by Paul. This paper presents the results of a study using the Leeds PA hip joint simulator to determine the wear of 32 mm ultra-high molecular weight polyethylene (UHMWPE) acetabular cups against stainless steel and zirconia ceramic heads, using bovine serum as lubricant. These results have been compared with the results of a previous study that used water as the lubricant, which led to UHMWPE transfer film being formed on the stainless steel head. Comparisons are also made with clinical results and results from other simulators. The study indicates that it is preferable to use bovine serum in simulator studies. In addition, the results indicate that if the surface roughness of the metallic and femoral heads are similar, and they remain undamaged during the tests, the wear rates of the UHMWPE cups are likely to be similar.
引用
收藏
页码:265 / 269
页数:5
相关论文
共 15 条
[1]  
COOPER JR, 1990, P I MECH ENG H, V204, P65
[2]   COMPARATIVE-STUDY OF THE WEAR OF UHMWPE WITH ZIRCONIA CERAMIC AND STAINLESS-STEEL FEMORAL HEADS IN ARTIFICIAL HIP JOINTS [J].
DERBYSHIRE, B ;
FISHER, J ;
DOWSON, D ;
HARDAKER, C ;
BRUMMITT, K .
MEDICAL ENGINEERING & PHYSICS, 1994, 16 (03) :229-236
[3]  
DERBYSHIRE B, 1994, P I MECH ENG H, V208, P151
[4]  
DOWSON D, 1988, ENG MED, V17, P1
[5]   PRELIMINARY-STUDY OF THE EFFECT OF AGING FOLLOWING IRRADIATION ON THE WEAR OF ULTRAHIGH-MOLECULAR-WEIGHT POLYETHYLENE [J].
FISHER, J ;
CHAN, KL ;
HAILEY, JL ;
SHAW, D ;
STONE, M .
JOURNAL OF ARTHROPLASTY, 1995, 10 (05) :689-692
[6]  
GREER KW, 1995, P 21 ANN M SOC BIOM
[7]  
GRIFFITH MJ, 1978, CLIN ORTHOP RELAT R, V137, P37
[8]  
Isaac G H, 1986, Eng Med, V15, P19
[9]   INVIVO WEAR OF POLYETHYLENE ACETABULAR COMPONENTS [J].
KABO, JM ;
GEBHARD, JS ;
LOREN, G ;
AMSTUTZ, HC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02) :254-258
[10]   EFFECT OF FEMORAL-HEAD SIZE ON WEAR OF THE POLYETHYLENE ACETABULAR COMPONENT [J].
LIVERMORE, J ;
ILSTRUP, D ;
MORREY, B .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (04) :518-528