Simultaneous ultratrace determination of Zr and Nb in chromium matrixes with ICP-dynamic reaction cell MS

被引:42
作者
Hattendorf, B [1 ]
Günther, D [1 ]
Schönbächler, M [1 ]
Halliday, A [1 ]
机构
[1] Swiss Fed Inst Technol, CH-8092 Zurich, Switzerland
关键词
D O I
10.1021/ac015549a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A dynamic reaction cell (DRC) has been used to minimize the formation of metal-argide ions in inductively coupled plasma mass spectrometry and applied to the determination of Zr and Nb in Cr-rich samples. The formation of ArCr+ species from the plasma gas and the sample matrix was reduced by ion molecule reactions inside a DRC of the ICPMS used. Hydrogen was used as reaction gas, and the efficiency in the reduction of ArCr+ was similar to that of other plasma-based polyatomic ions as reported in an earlier study. The formation of CrOx+ ions is enhanced when the DRC is operated in pressurized mode. Adjustment of the transmission properties of the band-pass quadrupole to reject precursor ions can be achieved without dramatic decrease of sensitivity but with a significant improvement in the signal/background ratio. Measurements in solutions containing concentrations of up to 2 g/L Cr showed that the determination of Nb and Zr is possible in the nanogram per liter range in such a matrix. The limits of detection for Nb and Zr in pure Cr metal have been estimated at 2 ng/g for Nb and 5 ng/g for Zr. Analysis of basaltic reference samples resulted in very good agreement with previously published data.
引用
收藏
页码:5494 / 5498
页数:5
相关论文
共 19 条
  • [1] [Anonymous], 1989, GEOSTANDARD NEWSLETT, DOI DOI 10.1111/J.1751-908X.1989.TB00476.X
  • [2] Investigations on cluster and molecular ion formation by plasma mass spectrometry
    Becker, JS
    Dietze, HJ
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (4-5): : 338 - 345
  • [3] Bollinger DS, 1999, ATOM SPECTROSC, V20, P60
  • [4] Denoyer ER, 1999, SPECTROSCOPY, V14, P43
  • [5] Analytical performance of the plasma source RF quadrupole ion trap in elemental and isotopic MS
    Eiden, GC
    Barinaga, CJ
    Koppenaal, DW
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (08) : 1129 - 1132
  • [6] Capabilities and limits of ICP-MS for direct determination of element traces in saline solutions
    Falk, H
    Geerling, R
    Hattendorf, B
    KrengelRothensee, K
    Schmidt, KP
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (4-5): : 352 - 356
  • [7] Application of a hexapole collision and reaction cell in ICP-MS Part I: Instrumental aspects and operational optimization
    Feldmann, I
    Jakubowski, N
    Stuewer, D
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (05): : 415 - 421
  • [8] GERLICH D, 1992, ADV CHEM PHYS, V82, P1
  • [9] Experimental evidence for the formation of doubly charged oxide and hydroxide ions in inductively coupled plasma mass spectrometry
    Hattendorf, B
    Günther, D
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) : 483 - 487
  • [10] Characteristics and capabilities of an ICP-MS with a dynamic reaction cell for dry aerosols and laser ablation
    Hattendorf, B
    Günther, D
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (09) : 1125 - 1131