Prospective evaluation of hemostatic predictors of subacute stent thrombosis after coronary Palmaz-Schatz stenting

被引:103
作者
Neumann, FJ
Gawaz, M
Ott, I
May, A
Mossmer, G
Schomig, A
机构
[1] TECH UNIV MUNICH, MED KLIN 1, D-81675 MUNICH, GERMANY
[2] TECH UNIV MUNICH, INST KLIN CHEM & PATHOBIOCHEM, D-81675 MUNICH, GERMANY
关键词
D O I
10.1016/0735-1097(95)00433-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. This study sought to investigate hemostatic predictors of subacute occlusive coronary stent thrombosis. Background. Better hemostatic monitoring may improve antithrombotic therapy after stenting. Methods. In 140 consecutive patients undergoing Palmaz-Schatz stent implantation for suboptimal angioplasty results, we obtained serial blood samples immediately before and daily for 12 days after stenting. We prospectively tested the hypothesis that subacute stent thrombosis was more frequent if the surface expression of the inducible fibrinogen receptor on platelets (flow cytometry) or the concentration of plasma fibrinogen or that of the prothrombin fragments F-1+2 before stent implantation exceeded the 75th percentile of the entire study cohort. Results. All five stent occlusions encountered during the study occurred in patients with platelet fibrinogen receptor expression above the 75th percentile. Thus, the rate of stent occlusion differed significantly between the groups defined by platelet fibrinogen receptor expression (13.3% vs, 0%, p = 0.0008), In both the group with fibrinogen concentration and that with F-1+2 concentration above the 75th percentile, three stent occlusions occurred, Between the groups defined by these variables, the rate of stent occlusion did not differ significantly (8.6% vs, 1.9%, p = 0.10). Logistic regression analysis, including angiographic and hemostatic variables, confirmed platelet fibrinogen receptor expression as an independent predictor of stent occlusion (p = 0.020). Stent occlusion could not be predicted by the time course of any of the hemostatic variables. Conclusions. Platelet fibrinogen receptor expression is an in dependent predictor of subacute stent occlusion, However, fibrinogen and F-1+2 concentrations do not show a strong relation to the risk of stent occlusion.
引用
收藏
页码:15 / 21
页数:7
相关论文
共 39 条
[31]   4-YEAR EXPERIENCE WITH PALMAZ-SCHATZ STENTING IN CORONARY ANGIOPLASTY COMPLICATED BY DISSECTION WITH THREATENED OR PRESENT VESSEL CLOSURE [J].
SCHOMIG, A ;
KASTRATI, A ;
MUDRA, H ;
BLASINI, R ;
SCHUHLEN, H ;
KLAUSS, V ;
RICHARDT, G ;
NEUMANN, FJ .
CIRCULATION, 1994, 90 (06) :2716-2724
[32]   A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
SERRUYS, PW ;
DEJAEGERE, P ;
KIEMENEIJ, F ;
MACAYA, C ;
RUTSCH, W ;
HEYNDRICKX, G ;
EMANUELSSON, H ;
MARCO, J ;
LEGRAND, V ;
MATERNE, P ;
BELARDI, J ;
SIGWART, U ;
COLOMBO, A ;
GOY, JJ ;
VANDENHEUVEL, P ;
DELCAN, J ;
MOREL, MA .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :489-495
[33]   EMERGENCY STENTING FOR ACUTE OCCLUSION AFTER CORONARY BALLOON ANGIOPLASTY [J].
SIGWART, U ;
URBAN, P ;
GOLF, S ;
KAUFMANN, U ;
IMBERT, C ;
FISCHER, A ;
KAPPENBERGER, L .
CIRCULATION, 1988, 78 (05) :1121-1127
[34]   MAJOR CLINICAL EVENTS AFTER CORONARY STENTING - THE MULTICENTER REGISTRY OF ACUTE AND ELECTIVE GIANTURCO-ROUBIN STENT PLACEMENT [J].
SUTTON, JM ;
ELLIS, SG ;
ROUBIN, GS ;
PINKERTON, CA ;
KING, SB ;
RAIZNER, AE ;
HOLMES, DR ;
KEREIAKES, DJ ;
TOPOL, EJ .
CIRCULATION, 1994, 89 (03) :1126-1137
[35]   PROTHROMBIN FRAGMENTS AND THROMBOTIC OCCLUSION OF CORONARY STENTS [J].
SWARS, H ;
HAFNER, G ;
ERBEL, R ;
EHRENTHAL, W ;
RUPPRECHT, HJ ;
PRELLWITZ, W ;
MEYER, J .
LANCET, 1991, 337 (8732) :59-60
[36]   CAVEATS ABOUT ELECTIVE CORONARY STENTING [J].
TOPOL, EJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :539-541
[37]   PLATELET MEMBRANE ACTIVATION MARKERS ARE PREDICTIVE FOR INCREASED RISK OF ACUTE ISCHEMIC EVENTS AFTER PTCA [J].
TSCHOEPE, D ;
SCHULTHEISS, HP ;
KOLAROV, P ;
SCHWIPPERT, B ;
DANNEHL, K ;
NIEUWENHUIS, HK ;
KEHREL, B ;
STRAUER, B ;
GRIES, FA .
CIRCULATION, 1993, 88 (01) :37-42
[38]   EFFICACY AND SAFETY OF COLLAGEN IMPLANTS FOR HEMOSTASIS OF THE VASCULAR ACCESS SITE AFTER CORONARY BALLOON ANGIOPLASTY AND CORONARY STENT IMPLANTATION - A RANDOMIZED STUDY [J].
VONHOCH, F ;
NEUMANN, FJ ;
THIESS, W ;
KASTRATI, A ;
SCHOMIG, A .
EUROPEAN HEART JOURNAL, 1995, 16 (05) :640-646
[39]   FIBRINOGEN, VISCOSITY, AND WHITE BLOOD-CELL COUNT ARE MAJOR RISK-FACTORS FOR ISCHEMIC-HEART-DISEASE - THE CAERPHILLY AND SPEEDWELL COLLABORATIVE HEART-DISEASE STUDIES [J].
YARNELL, JWG ;
BAKER, IA ;
SWEETNAM, PM ;
BAINTON, D ;
OBRIEN, JR ;
WHITEHEAD, PJ ;
ELWOOD, PC .
CIRCULATION, 1991, 83 (03) :836-844