Hepatocellular carcinoma in patients with chronic liver disease: Comparison of SPIO-enhanced MR imaging and 16-detector row CT

被引:87
作者
Kim, YK
Kwak, HS
Kim, CS
Chung, GH
Han, YM
Lee, JM
机构
[1] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul 110744, South Korea
[2] Chonbuk Natl Univ, Med Sch & Hosp, Dept Diagnost Radiol, Jeonju, South Korea
关键词
D O I
10.1148/radiol.2381042193
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: To compare the sensitivity, positive predictive value, and diagnostic accuracy of superparamagnetic iron, oxide (SPIO)-enhanced magnetic resonance (MR) imaging with those of 16-detector row computed tomography (CT) for the detection of hepatocellular carcinoma (HCC) in patients with hepatitis B-induced cirrhosis. Materials and Methods: Institutional Review Board approval was obtained for this study, and informed consent was obtained from all patients. A total of 44 patients (36 men, eight women; age range, 35-67 years) with 59 HCCs and mild liver cirrhosis (Child-Pugh score A or B) underwent multiphasic CT and SPIO-enhanced MR imaging. The diagnosis of HCC was established at surgical resection (n = 31) and percutaneous biopsy (n = 28). SPIO-enhanced MR imaging was composed of T2-weighted turbo spin-echo and T2*-weighted gradient-echo sequences. Multiphasic CT consisted of four phases (ie, early arterial, late arterial, portal venous, and equilibrium). Three observers independently analyzed each image in random order. Sensitivity, positive predictive value, and diagnostic accuracy were calculated by using the alternative free-response receiver operating characteristic analysis for multi-detector row CT and SPIO-enhanced MR imaging. Results: Although not significant (P >.05), the area under the receiver operating characteristic curve for SPIO-enhanced MR imaging (mean, 0.90) was higher than that for multidetector row CT (mean, 0.82) for all observers. Also, although no significant difference was demonstrated by any of the three observers (P >.05), there was a trend toward increased sensitivity on both a per-lesion and a per-patient basis for SPIO-enhanced MR imaging (mean, 84.7% and 94.7%, respectively) compared with multidetector row CT (mean, 76.9% and 88.6%, respectively). No significant difference in positive predictive value was observed between modalities. SPIO-enhanced MR imaging and multiphasic CT show similar diagnostic accuracy, sensitivity, and positive predictive value for the detection of HCC in patients with relatively mild hepatitis B-induced cirrhosis. (c) RSNA, 2005
引用
收藏
页码:531 / 541
页数:11
相关论文
共 43 条
[1]
Arii S, 1996, SEMIN SURG ONCOL, V12, P204, DOI 10.1002/(SICI)1098-2388(199605/06)12:3<204::AID-SSU11>3.3.CO
[2]
2-A
[3]
LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING [J].
BELLIN, MF ;
ZAIM, S ;
AUBERTON, E ;
SARFATI, G ;
DURON, JJ ;
KHAYAT, D ;
GRELLET, J .
RADIOLOGY, 1994, 193 (03) :657-663
[4]
Multidetector-array CT: Once again, technology creates new opportunities [J].
Berland, LL ;
Smith, JK .
RADIOLOGY, 1998, 209 (02) :327-329
[5]
Modern hepatic imaging [J].
Braga, L ;
Guller, U ;
Semelka, RC .
SURGICAL CLINICS OF NORTH AMERICA, 2004, 84 (02) :375-+
[6]
Observer studies involving detection and localization: Modeling, analysis, and validation [J].
Chakraborty, DP ;
Berbaum, KS .
MEDICAL PHYSICS, 2004, 31 (08) :2313-2330
[7]
FREE-RESPONSE METHODOLOGY - ALTERNATE ANALYSIS AND A NEW OBSERVER-PERFORMANCE EXPERIMENT [J].
CHAKRABORTY, DP ;
WINTER, LHL .
RADIOLOGY, 1990, 174 (03) :873-881
[8]
Choi Byung Ihn, 2004, Liver Transpl, V10, pS20, DOI 10.1002/lt.20038
[9]
Preoperative detection of hepatocellular carcinoma: Ferumoxides-enhanced MRI imaging versus combined helical CT during arterial portography and CT hepatic arteriography [J].
Choi, D ;
Kim, SH ;
Lim, JH ;
Lee, WJ ;
Jang, HJ ;
Lee, SJ ;
Lim, HK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :475-482
[10]
Colella G, 1998, Transpl Int, V11 Suppl 1, pS193, DOI 10.1007/s001470050459