Sensitivity, reliability and accuracy of the instant center of rotation calculation in the cervical spine during in vivo dynamic flexion-extension

被引:32
作者
Baillargeon, Emma [1 ]
Anderst, William J. [2 ]
机构
[1] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15203 USA
[2] Univ Pittsburgh, Dept Orthopaed Surg, Pittsburgh, PA 15203 USA
关键词
Helical axis; Center of rotation; Kinematics; Cervical disc replacement; TOTAL DISC REPLACEMENT; HELICAL AXIS; KNEE-JOINT; ANTERIOR DISKECTOMY; DEVICE EXEMPTION; HUMAN MOVEMENT; MOTION; KINEMATICS; AXES; VALIDATION;
D O I
10.1016/j.jbiomech.2012.11.055
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
The instant center of rotation (ICR) has been proposed as an alternative to range of motion (ROM) for evaluating the quality, rather than the quantity, of cervical spine movement. The purpose of the present study was to assess the sensitivity, reliability and accuracy of cervical spine ICR path calculations obtained during dynamic in vivo movement. The reliability and sensitivity of in vivo cervical spine ICR calculations were assessed by evaluating the effects of movement direction (flexion versus extension), rotation step size, filter frequency, and motion tracking error. The accuracy of the ICR path calculations was assessed through a simulation experiment that replicated in vivo movement of cervical vertebrae. The in vivo assessment included 20 asymptomatic subjects who performed continuous head flexionex-tension movements while biplane radiographs were collected at 30 frames per second. In vivo motion of C2 through C7 cervical vertebrae was tracked with sub-millimeter accuracy using a volumetric model-based tracking technique. The finite helical axis method was used to determine ICRs between each pair of adjacent vertebra. The in vivo results indicate ICR path is not different during the flexion movement and the extension movement. In vivo, the path of the ICR can reliably be characterized within 0.5 mm in the SI and 1.0 mm in the AP direction. The inter-subject variability in ICR location averaged +/- 1.2 mm in the Si direction and +/- 2.2 mm in the AP direction. The computational experiment estimated the in vivo accuracy in ICR location was between 1.1 mm and 3.1 mm. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:670 / 676
页数:7
相关论文
共 42 条
[1]
INSTANTANEOUS AXES OF ROTATION OF THE TYPICAL CERVICAL MOTION SEGMENTS - A STUDY IN NORMAL VOLUNTEERS [J].
AMEVO, B ;
WORTH, D ;
BOGDUK, N .
CLINICAL BIOMECHANICS, 1991, 6 (02) :111-117
[2]
ABNORMAL INSTANTANEOUS AXES OF ROTATION IN PATIENTS WITH NECK PAIN [J].
AMEVO, B ;
APRILL, C ;
BOGDUK, N .
SPINE, 1992, 17 (07) :748-756
[3]
KINEMATIC ANALYSIS OF HUMAN MOVEMENT [J].
AN, KN ;
CHAO, EY .
ANNALS OF BIOMEDICAL ENGINEERING, 1984, 12 (06) :585-597
[4]
Anderst W., J BONE JOIN IN PRESS
[5]
Validation of three-dimensional model-based tibio-femoral tracking during running [J].
Anderst, William ;
Zauel, Roger ;
Bishop, Jennifer ;
Demps, Erinn ;
Tashman, Scott .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (01) :10-16
[6]
Validation of a Noninvasive Technique to Precisely Measure In Vivo Three-Dimensional Cervical Spine Movement [J].
Anderst, William J. ;
Baillargeon, Emma ;
Donaldson, William F., III ;
Lee, Joon Y. ;
Kang, James D. .
SPINE, 2011, 36 (06) :E393-E400
[7]
Sagittal alignment and kinematics at instrumented and adjacent levels after total disc replacement in the cervical spine [J].
Barrey, Cedric ;
Champain, Sabina ;
Campana, Sophie ;
Ramadan, Aymen ;
Perrin, Gilles ;
Skalli, Wafa .
EUROPEAN SPINE JOURNAL, 2012, 21 (08) :1648-1659
[8]
Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics [J].
Bey, Michael J. ;
Zauel, Roger ;
Brock, Stephanie K. ;
Tashman, Scott .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (04) :604-609
[9]
Normal Functional Range of Motion of the Cervical Spine During 15 Activities of Daily Living [J].
Bible, Jesse E. ;
Biswas, Debdut ;
Miller, Christopher P. ;
Whang, Peter G. ;
Grauer, Jonathan N. .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2010, 23 (01) :15-21
[10]
Radiation Exposure from Musculoskeletal Computerized Tomographic Scans [J].
Biswas, Debdut ;
Bible, Jesse E. ;
Bohan, Michael ;
Simpson, Andrew K. ;
Whang, Peter G. ;
Grauer, Jonathan N. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (08) :1882-1889