Validation of three-dimensional model-based tibio-femoral tracking during running

被引:217
作者
Anderst, William [1 ]
Zauel, Roger [2 ]
Bishop, Jennifer [2 ]
Demps, Erinn [2 ]
Tashman, Scott [1 ]
机构
[1] Univ Pittsburgh, Dept Orthopaed Surg, Orthopaed Res Labs, Pittsburgh, PA 15203 USA
[2] Henry Ford Hosp, Ctr Bone & Joint, Henry Ford Hlth Syst, Detroit, MI 48202 USA
基金
美国国家卫生研究院;
关键词
Kinematics; Accuracy; Knee; Image registration; X-ray; RSA; IN-VIVO MEASUREMENT; KNEE KINEMATICS; JOINT KINEMATICS; DEFICIENT KNEE; MOTION; REGISTRATION; RADIOGRAPHS; FLUOROSCOPY; SYSTEM; IMAGES;
D O I
10.1016/j.medengphy.2008.03.003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to determine the accuracy of a radiographic model-based tracking technique that measures the three-dimensional in vivo motion of the tibio-femoral joint during running. Tantalum beads were implanted into the femur and tibia of three subjects and computed tomography (CT) scans were acquired after bead implantation. The subjects ran 2.5 m/s on a treadmill positioned within a biplane radiographic system while images were acquired at 250 frames per second. Three-dimensional implanted bead locations were determined and used as a "gold standard" to measure the accuracy of the model-based tracking. The model-based tracking technique optimized the correlation between the radiographs acquired via the biplane X-ray system and digitally reconstructed radiographs created from the volume-rendered CT model. Accuracy was defined in terms of measurement system bias, precision and root-mean-squared (rms) error. Results were reported in terms of individual bone tracking and in terms of clinically relevant tibio-femoral joint translations and rotations (joint kinematics). Accuracy for joint kinematics was as follows: model-based tracking measured static joint orientation with a precision of 0.2 degrees or better, and static joint position with a precision of 0.2 mm or better. Model-based tracking precision for dynamic joint rotation was 0.9 +/- 0.3 degrees, 0.6 +/- 0.3 degrees, and 0.3 +/- 0.1 degrees for flexion-extension, external-internal rotation, and ab-adduction, respectively. Model-based tracking precision when measuring dynamic joint translation was 0.3 +/- 0.1 mm, 0.4 +/- 0.2 mm, and 0.7 +/- 0.2 mm in the medial-lateral, proximal-distal, and anterior-posterior direction, respectively. The combination of high-speed biplane radiography and volumetric model-based tracking achieves excellent accuracy during in vivo, dynamic knee motion without the necessity for invasive bead implantation. (C) 2008 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:10 / 16
页数:7
相关论文
共 20 条
[1]  
ASTM, 1996, STAND PRACT US TERMS
[2]   Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[3]  
BERHONNAUD E, 2005, SURG RADIOL ANAT, V27, P214
[4]   Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics [J].
Bey, Michael J. ;
Zauel, Roger ;
Brock, Stephanie K. ;
Tashman, Scott .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (04) :604-609
[5]   An optimized image matching method for determining in-vivo TKA kinematics with a dual-orthogonal fluoroscopic imaging system [J].
Bingham, Jeffrey ;
Li, Guoan .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (04) :588-595
[6]   In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics [J].
Dennis, DA ;
Mahfouz, MR ;
Komistek, RD ;
Hoff, W .
JOURNAL OF BIOMECHANICS, 2005, 38 (02) :241-253
[7]  
GROOD E, 2007, J BIOMED ENG, V105, P136
[8]   Investigation of in vivo 6DOF total knee arthoplasty kinematics using a dual orthogonal fluoroscopic system [J].
Hanson, GR ;
Suggs, JF ;
Freiberg, AA ;
Durbhakula, S ;
Li, GA .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (05) :974-981
[9]   3-DIMENSIONAL INSTABILITY OF THE ANTERIOR CRUCIATE DEFICIENT KNEE [J].
KARRHOLM, J ;
SELVIK, G ;
ELMQVIST, LG ;
HANSSON, LI ;
JONSSON, H .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (05) :777-783
[10]   A PATIENT-TO-COMPUTED-TOMOGRAPHY IMAGE REGISTRATION METHOD BASED ON DIGITALLY RECONSTRUCTED RADIOGRAPHS [J].
LEMIEUX, L ;
JAGOE, R ;
FISH, DR ;
KITCHEN, ND ;
THOMAS, DGT .
MEDICAL PHYSICS, 1994, 21 (11) :1749-1760