The need for correct realistic geometry in the inverse EEG problem

被引:79
作者
Huiskamp, G [1 ]
Vroeijenstijn, M [1 ]
van Dijk, R [1 ]
Wieneke, G [1 ]
van Huffelen, AC [1 ]
机构
[1] Univ Utrecht Hosp, Dept Clin Neurophysiol, NL-3508 GA Utrecht, Netherlands
关键词
boundary element method (BEM); dipole modeling; electroencephalogram (EEG); epilepsy surgery; realistic head model;
D O I
10.1109/10.797987
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For accurate electroencephalogram-based localization of mesial temporal and frontal sources correct modeling of skull shape and thickness is required. In a simulation study in which results for matched sets of computed tomography and magnetic resonance (MR) images are compared, it is found that errors arising from skull models based on smooth and inflated segmented MR images of the cortex are of the order of I cm, These errors are comparable to those found when overestimating or underestimating skull conductivity by a factor of two.
引用
收藏
页码:1281 / 1287
页数:7
相关论文
共 11 条
  • [1] BOON P, 1996, EPILEPSIA, V38, P208
  • [2] EFFECTS OF LOCAL VARIATIONS IN SKULL AND SCALP THICKNESS ON EEGS AND MEGS
    CUFFIN, BN
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1993, 40 (01) : 42 - 48
  • [3] EEG localization accuracy improvements using realistically shaped head models
    Cuffin, BN
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (03) : 299 - 303
  • [4] HUISKAMP G, 1997, BIOMED TECH, V42, P84
  • [5] ON THE NUMERICAL ACCURACY OF THE BOUNDARY ELEMENT METHOD
    MEIJS, JWH
    WEIER, OW
    PETERS, MJ
    VANOOSTEROM, A
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (10) : 1038 - 1049
  • [6] SOURCE PARAMETER-ESTIMATION IN INHOMOGENEOUS VOLUME CONDUCTORS OF ARBITRARY SHAPE
    OOSTENDORP, TF
    VANOOSTEROM, A
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (03) : 382 - 391
  • [7] Dipole localization in patients with epilepsy using the realistically shaped head model
    Roth, BJ
    Ko, D
    vonAlbertiniCarletti, IR
    Scaffidi, D
    Sato, S
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 102 (03): : 159 - 166
  • [8] HOW WELL DOES A 3-SPHERE MODEL PREDICT POSITIONS OF DIPOLES IN A REALISTICALLY SHAPED HEAD
    ROTH, BJ
    BALISH, M
    GORBACH, A
    SATO, S
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1993, 87 (04): : 175 - 184
  • [9] van den Elsen P A, 1991, Brain Topogr, V3, P425
  • [10] COMBINED USE OF SUBDURAL AND INTRACEREBRAL ELECTRODES IN PREOPERATIVE EVALUATION OF EPILEPSY
    VANVEELEN, CWM
    DEBETS, RMC
    VANHUFFELEN, AC
    BOAS, WV
    BINNIE, CD
    VANLEEUWEN, WS
    VELIS, DN
    VANDIEREN, A
    [J]. NEUROSURGERY, 1990, 26 (01) : 93 - 101