[2] NINCDS,EPILEPSY RES BRANCH,CLIN NEUROPHYSIOL UNIT,BETHESDA,MD 20892
来源:
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY
|
1993年
/
87卷
/
04期
基金:
美国国家卫生研究院;
关键词:
EEG;
DIPOLE;
LOCALIZATION;
REALISTICALLY SHAPED HEAD MODEL;
3-SPHERE MODEL;
D O I:
10.1016/0013-4694(93)90017-P
中图分类号:
R318 [生物医学工程];
学科分类号:
0831 ;
摘要:
The electrical potential produced by a dipole in the temporal or frontal lobe was calculated for a realistically shaped scalp, skull, and brain. This potential distribution was then used with a 3-sphere model to predict the position, orientation, and strength of the dipole source. The original and predicted dipole positions differed by an average of 1.97 cm, with a difference of more than 4 cm in some cases. Control calculations demonstrated that this difference was not caused by numerical artifacts in the computation, but instead was due to a true difference between the 3-sphere and realistically shaped head models.