On the risk of false positive identification using multiple ion monitoring in qualitative mass spectrometry: Large-scale intercomparisons with a comprehensive mass spectral library

被引:27
作者
Stein, Stephen E.
Heller, David N.
机构
[1] NIST, Mass Spectrometry Data Ctr, Gaithersburg, MD 20899 USA
[2] FDA Ctr Vet Med, Laurel, MD USA
关键词
D O I
10.1016/j.jasms.2006.02.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Analysts involved in qualitative mass spectrometry have long debated the minimum data requirements for demonstrating that signals from an unknown sample are identical to those from a known compound. Often this process is carried out by comparing a few selected ions acquired by multiple ion monitoring (MIM), with due allowance for expected variability in response. In a few past experiments with electron-ionization mass spectrometry (EI-MS), the number of ions selected and the allowable variability in relative abundance were tested by comparing one spectrum against a library of mass spectra, where library spectra served to represent potential false positive signals in an analysis. We extended these experiments by carrying out large-scale intercomparisons between thousands of spectra and a library of one hundred thousand El mass spectra. The results were analyzed to gain insights into the identification confidence associated with various numbers of selected ions. A new parameter was investigated for the first time, to take into account that a library spectrum with a different base peak than the search spectrum may still cause a false positive identification. The influence of peak correlation among the specific ions in all the library mass spectra was also studied. Our computations showed that (1) false positive identifications can result from similar compounds, or low-abundance peaks in unrelated compounds if the method calls for detection at very low levels; (2) a MIM method's identification confidence improves in a roughly continuous manner as more ions are monitored, about one order of magnitude for each additional ion selected; (3) full scan spectra still represent the best alternative, if instrument sensitivity is adequate. The use of large scale intercomparisons with a comprehensive library is the only way to provide direct evidence in support of these conclusions, which otherwise depend on the judgment and experience of individual analysts. There are implications for residue chemists who would rely on standardized confirmation criteria to assess the validity of a given confirmatory method. For example, standardized confirmation criteria should not be used in the absence of interference testing and rational selection of diagnostic ions.
引用
收藏
页码:823 / 835
页数:13
相关论文
共 18 条
[1]   The critical evaluation of a comprehensive mass spectral library [J].
Ausloos, P ;
Clifton, CL ;
Lias, SG ;
Mikaya, AI ;
Stein, SE ;
Tchekhovskoi, DV ;
Sparkman, OD ;
Zaikin, V ;
Zhu, D .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (04) :287-299
[2]  
Baldwin R, 1997, J AM SOC MASS SPECTR, V8, P1180
[3]   Establishing the fitness for purpose of mass spectrometric methods [J].
Bethem, R ;
Boison, J ;
Gale, J ;
Heller, D ;
Lehotay, S ;
Loo, J ;
Musser, S ;
Price, P ;
Stein, S .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (05) :528-541
[4]   Reproducible product-ion tandem mass spectra on various liquid chromatography/mass spectrometry instruments for the development of spectral libraries [J].
Bristow, AWT ;
Webb, KS ;
Lubben, AT ;
Halket, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (13) :1447-1454
[5]   Potential for false positive identifications from large databases through tandem mass spectrometry [J].
Cargile, BJ ;
Bundy, JL ;
Stephenson, JL .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (05) :1082-1085
[6]  
*FDA CTR VET MED G, 2003, 118 FDA CTR VET MED
[7]   Evaluation of electrospray transport CID for the generation of searchable libraries [J].
Hough, JM ;
Haney, CA ;
Voyksner, RD ;
Bereman, RD .
ANALYTICAL CHEMISTRY, 2000, 72 (10) :2265-2270
[8]   Creation and comparison of MS/MS spectral libraries using quadrupole ion trap and triple-quadruople mass spectrometers [J].
Josephs, JL ;
Sanders, M .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (07) :743-759
[9]  
*NIST EPA NIH, 2002, MASS SPECTR LIB NIST
[10]   PROBABILITY BASED MATCHING SYSTEM USING A LARGE COLLECTION OF REFERENCE MASS-SPECTRA [J].
PESYNA, GM ;
VENKATARAGHAVAN, R ;
DAYRINGER, HE ;
MCLAFFERTY, FW .
ANALYTICAL CHEMISTRY, 1976, 48 (09) :1362-1368