Evaluation of dual-energy X-ray absorptiometry for body-composition assessment in piglets and term human neonates

被引:100
作者
Picaud, JC
Rigo, J
Nyamugabo, K
Milet, J
Senterre, J
机构
[1] UNIV LIEGE,DEPT NEONATOL,B-4000 LIEGE,BELGIUM
[2] HOP CITADELLE,DEPT NUCL MED,LIEGE,BELGIUM
关键词
body composition; bone mineral content; dual-energy X-ray absorptiometry; human neonates; piglets; total body fat;
D O I
10.1093/ajcn/63.2.157
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
The reproducibility, accuracy, and precision of dual-energy X-ray absorptiometry (DXA) was assessed by scanning 13 piglets (1471-5507 g) in triplicate. In four piglets, fat content was increased with porcine lard around the abdomen; additional measurements were performed on these animals. Reproducibility in DXA measurements from the animals without added fat was 0.09% for body weight, 1.95% for bone mineral content (BMC), and 5.35% for fat content. DXA estimates of body weight, BMC, and fat content were significantly correlated with scale body weight, ash weight, chemical calcium, and chemical fat. Body weight was measured accurately but fat content was overestimated by DXA. Mean BMC estimated by DXA represented 48% of ash weight and 215% of calcium content. The precision of DXA was 0.23% for body weight, 10.99% for ash weight, and 4.44% for calcium content. The precision of DXA for fat content was poor. However, for measurements performed in piglets with > 250 g fat, the precision was 8.85%. Thirty appropriate-for-gestational-age term human neonates (birth weight: 3188 +/- 217 g) were scanned once during the first week of Life. BMC and fat content were 54 +/- 6 and 470 +/- 92 g, respectively, which corresponded to 26.4 +/- 2.6 g calcium and 427 +/- 82 g fat. These were dose to the reference values previously determined by chemical analysis. This study suggests that DXA is accurate and reliable for measurement of calcium and fat contents in human neonates. Further refinements would be beneficial for determining fat content in preterm human infants.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 37 条
[1]  
Altman DG, 1991, PRACTICAL STAT MED R, P611, DOI [10.1002/sim.4780101015, DOI 10.1002/SIM.4780101015]
[2]  
BAUER K, 1994, SEMIN PERINATOL, V18, P11
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   DUAL ENERGY X-RAY ABSORPTIOMETRY MEASUREMENT OF BONE-MINERAL CONTENT IN NEWBORNS - VALIDATION OF THE TECHNIQUE [J].
BRAILLON, PM ;
SALLE, BL ;
BRUNET, J ;
GLORIEUX, FH ;
DELMAS, PD ;
MEUNIER, PJ .
PEDIATRIC RESEARCH, 1992, 32 (01) :77-80
[5]   VALIDATION AND APPLICATION OF DUAL-ENERGY X-RAY ABSORPTIOMETRY TO MEASURE BONE MASS AND BODY-COMPOSITION IN SMALL INFANTS [J].
BRUNTON, JA ;
BAYLEY, HS ;
ATKINSON, SA .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 58 (06) :839-845
[6]  
CHAN GM, 1992, J BONE MINER RES, V7, P369
[7]  
CHEYNE GA, 1964, TECHNIQUES CHEM PATH, P254
[8]   TOTAL-BODY ELECTRICAL-CONDUCTIVITY USED TO DETERMINE BODY-COMPOSITION IN INFANTS [J].
COCHRAN, WJ ;
KLISH, WJ ;
WONG, WW ;
KLEIN, PD .
PEDIATRIC RESEARCH, 1986, 20 (06) :561-564
[9]   BODY-FAT AND FAT-FREE MASS IN INFANTS - NEW AND CLASSIC ANTHROPOMETRIC INDEXES AND PREDICTION EQUATIONS COMPARED WITH TOTAL-BODY ELECTRICAL-CONDUCTIVITY [J].
DEBRUIN, NC ;
VANVELTHOVEN, KA ;
STIJNEN, T ;
JUTTMANN, RE ;
DEGENHART, HJ ;
VISSER, HK .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1995, 61 (06) :1195-1205
[10]   BODY ELEMENTAL COMPOSITION OF THE NEONATE - NEW REFERENCE DATA [J].
ELLIS, KJ ;
SHYPAILO, RJ ;
SCHANLER, RJ ;
LANGSTON, C .
AMERICAN JOURNAL OF HUMAN BIOLOGY, 1993, 5 (03) :323-330