Decision support system for diabetic retinopathy using discrete wavelet transform

被引:38
作者
Noronha, K. [1 ]
Acharya, U. R. [2 ,3 ]
Nayak, K. P. [1 ]
Kamath, S. [1 ]
Bhandary, S., V [4 ]
机构
[1] Manipal Inst Technol, Dept Elect & Commun, Manipal 576104, Karnataka, India
[2] Ngee Ann Polytech, Dept Elect & Comp Engn, Singapore, Singapore
[3] Univ Malaya, Dept Biomed Engn, Fac Engn, Kuala Lumpur, Malaysia
[4] Kasturba Med Coll & Hosp, Dept Ophthalmol, Manipal, Karnataka, India
关键词
Eye; diabetic retinopathy; support vector machine; discrete wavelet transform; classifier; RED LESIONS; IDENTIFICATION;
D O I
10.1177/0954411912470240
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Prolonged duration of the diabetes may affect the tiny blood vessels of the retina causing diabetic retinopathy. Routine eye screening of patients with diabetes helps to detect diabetic retinopathy at the early stage. It is very laborious and time-consuming for the doctors to go through many fundus images continuously. Therefore, decision support system for diabetic retinopathy detection can reduce the burden of the ophthalmologists. In this work, we have used discrete wavelet transform and support vector machine classifier for automated detection of normal and diabetic retinopathy classes. The wavelet-based decomposition was performed up to the second level, and eight energy features were extracted. Two energy features from the approximation coefficients of two levels and six energy values from the details in three orientations (horizontal, vertical and diagonal) were evaluated. These features were fed to the support vector machine classifier with various kernel functions (linear, radial basis function, polynomial of orders 2 and 3) to evaluate the highest classification accuracy. We obtained the highest average classification accuracy, sensitivity and specificity of more than 99% with support vector machine classifier (polynomial kernel of order 3) using three discrete wavelet transform features. We have also proposed an integrated index called Diabetic Retinopathy Risk Index using clinically significant wavelet energy features to identify normal and diabetic retinopathy classes using just one number. We believe that this (Diabetic Retinopathy Risk Index) can be used as an adjunct tool by the doctors during the eye screening to cross-check their diagnosis.
引用
收藏
页码:251 / 261
页数:11
相关论文
共 29 条
[11]   A Decision Support Framework for Automated Screening of Diabetic Retinopathy [J].
Kahai, P. ;
Namuduri, K. R. ;
Thompson, H. .
INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2006, 2006
[12]  
Kociolek M., 2001, P INT C SIGNALS ELEC, P163
[13]   Automated detection of fundus photographic red lesions in diabetic retinopathy [J].
Larsen, M ;
Godt, J ;
Larsen, N ;
Lund-Andersen, H ;
Sjolie, AK ;
Agardh, E ;
Kalm, H ;
Grunkin, M ;
Owens, DR .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (02) :761-766
[14]   Computer classification of nonproliferative diabetic retinopathy [J].
Lee, SC ;
Lee, ET ;
Wang, YM ;
Klein, R ;
Kingsley, RM ;
Warn, A .
ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (06) :759-764
[15]   Data mining technique for automated diagnosis of glaucoma using higher order spectra and wavelet energy features [J].
Mookiah, Muthu Rama Krishnan ;
Acharya, U. Rajendra ;
Lim, Choo Min ;
Petznick, Andrea ;
Suri, Jasjit S. .
KNOWLEDGE-BASED SYSTEMS, 2012, 33 :73-82
[16]   Automated identification of diabetic retinopathy stages using digital fundus images [J].
Nayak, Jagadish ;
Bhat, P. Subbanna ;
Acharya, Rajendra U. ;
Lim, C. M. ;
Kagathi, Manjunath .
JOURNAL OF MEDICAL SYSTEMS, 2008, 32 (02) :107-115
[17]   Automatic detection of red lesions in digital color fundus photographs [J].
Niemeijer, M ;
van Ginneken, B ;
Staal, J ;
Suttorp-Schulten, MSA ;
Abràmoff, MD .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (05) :584-592
[18]   A comparative evaluation of digital imaging, retinal photography and optometrist examination in screening for diabetic retinopathy [J].
Olson, JA ;
Strachan, FM ;
Hipwell, JH ;
Goatman, KA ;
McHardy, KC ;
Forrester, JV ;
Sharp, PF .
DIABETIC MEDICINE, 2003, 20 (07) :528-534
[19]  
Osareh A., 2002, Medical Image Computing and Computer-Assisted Intervention - MICCAI 2002. 5th International Conference. Proceedings, Part II (Lecture Notes in Computer Science Vol.2489), P413
[20]   PHOTOCOAGULATION FOR DIABETIC MACULAR EDEMA - EARLY TREATMENT DIABETIC-RETINOPATHY STUDY REPORT 1. EARLY TREATMENT DIABETIC RETINOPATHY STUDY RESEARCH GROUP [J].
PATZ, A ;
RICE, TA ;
MURPHY, RP ;
NEWSOME, DA ;
SHERMAN, SH ;
FINE, SL ;
AIELLO, LM ;
RAND, LI ;
BRIONES, JC ;
SHAH, ST ;
MYERS, FL ;
BRESNICK, GH ;
DAVIS, MD ;
CHANDRA, SR ;
WALLOW, IHL ;
STEVENS, TS ;
KLEIN, R ;
FLYNN, HW ;
BLANKENSHIP, GW ;
KNOBLOCH, WH ;
RAMSAY, RC ;
CANTRILL, HL ;
HODGKINSON, BJ ;
RYAN, SJ ;
LIANG, JC ;
THOMAS, EL ;
KLEIN, ML ;
HANDELMAN, IL ;
SIPPERLEY, JO ;
CHENOWETH, RG ;
ERNEST, JT ;
LIANG, JC ;
CUNHA-VAZ, J ;
GOLDBERG, MF ;
LINDBERG, CR ;
VYGANTAS, C ;
KLEIN, HJ ;
BLAIR, N ;
REDNAM, K ;
KOPELOW, SM ;
SHABO, AL ;
STRAATSMA, BR ;
BRIONES, JC ;
KASSOFF, A ;
LITTLE, HL ;
JACK, RL ;
CAVENDER, JC ;
AI, E ;
SORENSON, RL ;
TASMAN, WS .
ARCHIVES OF OPHTHALMOLOGY, 1985, 103 (12) :1796-1806