Use of a self-expanding vascular occluder for embolization during endovascular aortic aneurysm repair

被引:17
作者
Kato, N [1 ]
Semba, CP [1 ]
Dake, MD [1 ]
机构
[1] STANFORD UNIV,CTR MED,DIV CARDIOVASC INTERVENT RADIOL,STANFORD VASC CTR,STANFORD,CA 94305
关键词
aneurysm; therapy; aorta; graft and prostheses; arteries; therapeutic blockade;
D O I
10.1016/S1051-0443(97)70509-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: Repair of aortic aneurysms with use of stent-graft techniques may require occlusion of large branch vessels to prevent back-bleeding into the excluded aneurysmal sac. The authors describe their experience using a self-expanding vascular occluder (SEVO) to occlude flow in branch arteries during aortic stent-grafting. PATIENTS AND METHODS: Eighty-four patients (65 men, 19 women; mean age, 64 years) underwent thoracic (n = 72) or abdominal aortic (n = 12) stent-grafting. Aneurysm repair was performed using nonbifurcated Z stents covered with polyester or polytetrafluoroethylene (PTFE) fabric. SEVOs constructed from a Z stent (10-20 mm diameter) and PTFE were deployed through a separate catheter (14-20 F). RESULTS: Ten of 84 patients required embolization of large branch arteries with use of a SEVO during aortic stent-grafting (thoracic, n = 1; abdominal, n = 9). The SEVO was placed in the common iliac (n = 9) or subclavian artery (n = 1). The mean SEVO diameter was 14.7 mm (range, 10-20 mm). Eight patients undergoing SEVO embolization had immediate thrombosis of the treated artery. One patient required additional embolization with use of conventional coils. No patients had back-bleeding into the aneurysm, device migration, microembolization, or limb ischemia (mean follow-up, 140 days; range, 50-200). All 10 patients had complete thrombosis of the aortic aneurysm. CONCLUSION: Use of a novel self-expanding vascular occluding device is a safe and effective supplementary technique to occlude high-flow, large-diameter arterial branch vessels during endovascular aortic aneurysm repair.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 16 条
[1]   EMBOLOTHERAPY OF PULMONARY ARTERIOVENOUS-MALFORMATIONS WITH DETACHABLE BALLOONS [J].
BARTH, KH ;
WHITE, RI ;
KAUFMAN, SL ;
TERRY, PB ;
ROLAND, JM .
RADIOLOGY, 1982, 142 (03) :599-606
[2]   Abdominal aortic aneurysms: Preliminary technical and clinical results with transfemoral placement of endovascular self-expanding stent-grafts [J].
Blum, U ;
Langer, M ;
Spillner, G ;
Mialhe, C ;
Beyersdorf, F ;
BuitragoTellez, C ;
Voshage, G ;
Duber, C ;
Schlosser, V ;
Cragg, AH .
RADIOLOGY, 1996, 198 (01) :25-31
[3]  
Chuter T A, 1995, Cardiovasc Surg, V3, P121, DOI 10.1016/0967-2109(95)90884-8
[4]   INFRARENAL AORTIC-ANEURYSM STRUCTURE - IMPLICATIONS FOR TRANSFEMORAL REPAIR [J].
CHUTER, TAM ;
GREEN, RM ;
OURIEL, K ;
DEWEESE, JA .
JOURNAL OF VASCULAR SURGERY, 1994, 20 (01) :44-50
[5]   TRANSLUMINAL PLACEMENT OF ENDOVASCULAR STENT-GRAFTS FOR THE TREATMENT OF DESCENDING THORACIC AORTIC-ANEURYSMS [J].
DAKE, MD ;
MILLER, DC ;
SEMBA, CP ;
MITCHELL, RS ;
WALKER, PJ ;
LIDDELL, RP .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (26) :1729-1734
[6]   ANEURYSM OF ABDOMINAL AORTA - ANALYSIS OF RESULTS OF GRAFT REPLACEMENT THERAPY 1 TO 11 YEARS AFTER OPERATION [J].
DEBAKEY, ME ;
CRAWFORD, ES ;
MORRIS, GC ;
COOLEY, DA ;
ROYSTER, TS ;
ABBOTT, WP .
ANNALS OF SURGERY, 1964, 160 (04) :622-+
[7]   Embolization of perigraft leaks after endovascular stent-graft treatment of aortic aneurysms [J].
Kato, N ;
Semba, CP ;
Dake, MD .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 7 (06) :805-811
[8]   TREATMENT OF COMPLEX ABDOMINAL AORTIC-ANEURYSMS BY A COMBINATION OF ENDOLUMINAL AND EXTRALUMINAL AORTOFEMORAL GRAFTS [J].
MAY, J ;
WHITE, G ;
WAUGH, R ;
YU, WY ;
HARRIS, J .
JOURNAL OF VASCULAR SURGERY, 1994, 19 (05) :924-933
[9]   Endovascular stent-graft repair of thoracic aortic aneurysms [J].
Mitchell, RS ;
Dake, MD ;
Semba, CP ;
Fogarty, TJ ;
Zarins, CK ;
Liddell, RP ;
Miller, DC .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (05) :1054-1060
[10]   Infrarenal abdominal aortic aneurysms: Implications of CT evaluation of size and configuration for placement of endovascular aortic grafts [J].
Moritz, JD ;
Rotermund, S ;
Keating, DP ;
Oestmann, JW .
RADIOLOGY, 1996, 198 (02) :463-466