Three-dimensional endoscopic optical coherence tomography by use of a two-axis microelectromechanical scanning mirror

被引:94
作者
Jung, W [1 ]
McCormick, DT
Zhang, J
Wang, L
Tien, NC
Chen, ZP
机构
[1] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA 92617 USA
[2] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92617 USA
[3] Univ Calif Irvine, Dept Elect Engn, Irvine, CA 92617 USA
[4] Berkeley Sensor & Actuator Ctr, Berkeley, CA 94720 USA
[5] Adriatic Res Inst, Berkeley, CA 94720 USA
[6] Case Western Reserve Univ, Dept Elect Engn & Comp Sci, Cleveland, OH 44106 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
D O I
10.1063/1.2195092
中图分类号
O59 [应用物理学];
学科分类号
摘要
We present a three-dimensional (3D) endoscopic optical coherence tomography (OCT) system based on a dual-axis scanning microelectromechanical system (MEMS) mirror. The diameter of the MEMS mirror was 1.2 mm and both axes were capable of scanning greater than 20 degrees with linearity. The endoscopic MEMS probe was integrated with an OCT system and volume images were obtained at a rate of 3 frames/s by means of two-axis lateral scanning combined with an axial scan. In the initial investigations, 3D OCT images of healthy rabbit trachea as well as images of normal and cancerous regions of hamster cheek pouch tissue were obtained. (c) 2006 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 14 条
[1]
Power-efficient nonreciprocal interferometer and linear-scanning fiber-optic catheter for optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ .
OPTICS LETTERS, 1999, 24 (08) :531-533
[2]
HEE MR, 1995, ARCH OPHTHALMOL-CHIC, V113, P326
[3]
OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[4]
Gimbal-less monolithic silicon actuators for tip-tilt-piston micromirror applications [J].
Milanovic, V ;
Matus, GA ;
McCormick, DT .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2004, 10 (03) :462-471
[5]
Multilevel beam SOI-MEMS fabrication and applications [J].
Milanovic, V .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2004, 13 (01) :19-30
[6]
Endoscopic optical coherence tomography based on a microelectromechanical mirror [J].
Pan, YT ;
Xie, HK ;
Fedder, GK .
OPTICS LETTERS, 2001, 26 (24) :1966-1968
[7]
Real-time in vivo imaging of human gastrointestinal ultrastructure by use of endoscopic optical coherence tomography with a novel efficient interferometer design [J].
Rollins, AM ;
Ung-arunyawee, R ;
Chak, A ;
Wong, RCK ;
Kobayashi, K ;
Sivak, MV ;
Izatt, JA .
OPTICS LETTERS, 1999, 24 (19) :1358-1360
[8]
High-speed phase- and group-delay scanning with a grating-based phase control delay line [J].
Tearney, GJ ;
Bouma, BE ;
Fujimoto, JG .
OPTICS LETTERS, 1997, 22 (23) :1811-1813
[9]
In vivo endoscopic optical biopsy with optical coherence tomography [J].
Tearney, GJ ;
Brezinski, ME ;
Bouma, BE ;
Boppart, SA ;
Pitris, C ;
Southern, JF ;
Fujimoto, JG .
SCIENCE, 1997, 276 (5321) :2037-2039
[10]
Phase-resolved optical Doppler tomography for imaging flow dynamics in microfluidic channels [J].
Wang, L ;
Xu, W ;
Bachman, M ;
Li, GP ;
Chen, ZP .
APPLIED PHYSICS LETTERS, 2004, 85 (10) :1855-1857