Clinical value of measurement of pulmonary radioaerosol mucociliary clearance in the work up of primary ciliary dyskinesia

被引:11
作者
Munkholm, Mathias [1 ]
Nielsen, Kim Gjerum [2 ]
Mortensen, Jann [1 ,3 ]
机构
[1] Copenhagen Univ Hosp, Rigshosp, Dept Clin Physiol Nucl Med & PET, DK-2100 Copenhagen O, Denmark
[2] Copenhagen Univ Hosp, Rigshosp, Dept Pediat & Adolescent Med, Danish PCD Ctr,Pediat Pulm Serv, DK-2100 Copenhagen O, Denmark
[3] Faroese Natl Hosp, Nucl Med Sect, Dept Med, Torshavn, Faroe Islands, Denmark
来源
EJNMMI RESEARCH | 2015年 / 5卷
关键词
Mucociliary clearance; Diagnostic test; Primary ciliary dyskinesia; NASAL NITRIC-OXIDE; TRACHEOBRONCHIAL CLEARANCE; DIAGNOSIS;
D O I
10.1186/s13550-015-0118-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: We aimed to evaluate and define the general clinical applicability and impact of pulmonary radioaerosol mucociliary clearance (PRMC) on the work up of patients suspected of having primary ciliary dyskinesia (PCD). In addition, we wanted to evaluate the accuracy of the reference values used in the PRMC test. Methods: Measurement of PRMC after inhalation of Tc-99m-albumin colloid aerosol was carried out on 239 patients (4-75 years of age) during a 9-year period. All were referred to the nuclear medicine department because of clinical suspicion of PCD. The results were compared primarily to results from nasal ciliary function testing, to electron microscopic (EM) examination of the ultrastructure of the cilia, and to the final clinical diagnosis. Results: Of the 239 patients, 27 ended up with a final clinical diagnosis of definitive PCD. No patients with a PRMC test that was normal or otherwise not consistent with PCD ended up with PCD as final clinical diagnosis (though a minority of patients in this group ended up unresolved in regard to PCD). Forty percent of patients with an abnormal PRMC test ended up with PCD as final clinical diagnosis. Furthermore, the PRMC test had a high rate of conclusive results (90 %). Children <14 years of age with normal PRMC measurements showed significantly faster lung clearance than adults with similarly normal PRMC measurements. Conclusions: To this date, PRMC is the only test providing evaluation of the mucociliary clearance of the entire lung. Its greatest strength is its ability to reject a suspected PCD diagnosis with great certainty. In our material, this accounted for 2/3 of referred patients. In addition, the test has a high rate of conclusive results. According to our analyses, reference equations on children would benefit from updated data.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 34 条
[11]   Ciliated Air-Liquid Cultures as an Aid to Diagnostic Testing of Primary Ciliary Dyskinesia [J].
Hirst, Robert A. ;
Rutman, Andrew ;
Williams, Gwyneth ;
Callaghan, Chris O. .
CHEST, 2010, 138 (06) :1441-1447
[12]  
Leigh Margaret W, 2011, Proc Am Thorac Soc, V8, P434, DOI 10.1513/pats.201103-028SD
[13]   Diagnosis and management of primary ciliary dyskinesia [J].
Lucas, Jane S. ;
Burgess, Andrea ;
Mitchison, Hannah M. ;
Moya, Eduardo ;
Williamson, Michael ;
Hogg, Claire .
ARCHIVES OF DISEASE IN CHILDHOOD, 2014, 99 (09) :850-856
[14]   Choice of nasal nitric oxide technique as first-line test for primary ciliary dyskinesia [J].
Marthin, J. K. ;
Nielsen, K. G. .
EUROPEAN RESPIRATORY JOURNAL, 2011, 37 (03) :559-565
[15]   Pulmonary radioaerosol mucociliary clearance in diagnosis of primary ciliary dyskinesia [J].
Marthin, June Kehlet ;
Mortensen, Jann ;
Pressler, Tacjana ;
Nielsen, Kim Gjerum .
CHEST, 2007, 132 (03) :966-976
[16]  
Marthin June Kehlet, 2010, Dan Med Bull, V57, pB4174
[17]  
MORTENSEN J, 1994, EUR J NUCL MED, V21, P953
[18]  
Mortensen J, 1998, DAN MED BULL, V45, P195
[19]   THE EFFECT OF FORCED EXPIRATIONS ON MUCOCILIARY CLEARANCE IN PATIENTS WITH CHRONIC-BRONCHITIS AND IN HEALTHY-SUBJECTS [J].
MORTENSEN, J ;
JENSEN, C ;
GROTH, S ;
LANGE, P .
CLINICAL PHYSIOLOGY, 1991, 11 (05) :439-450
[20]   Mucociliary clearance: pathophysiological aspects [J].
Munkholm, Mathias ;
Mortensen, Jann .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2014, 34 (03) :171-177