Technique of color Doppler quantification of vascularity in transplanted kidneys

被引:4
作者
Gruenewald, S
Skerrett, D
Dolimier, D
Nankivell, B
机构
[1] Westmead Hosp, Dept Nucl Med & Ultrasound, Sydney, NSW 2145, Australia
[2] Westmead Hosp, Dept Med Phys, Sydney, NSW 2145, Australia
[3] Philips Med Syst, ATL Ultrasound, HDI Lab Support, Bothell, WA 98041 USA
[4] Westmead Hosp, Dept Renal Med, Sydney, NSW 2145, Australia
关键词
color Doppler ultrasonography; vascularity quantification; kidney transplants;
D O I
10.1002/jcu.10044
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A new technique for the quantification of vascularity based on the analysis of color Doppler images is described. We utilized velocity information obtained directly from cineloops transferred to a computer for off-line analysis. This methodology was used in transplanted kidneys to assess parenchymal vascularity on the basis of percentage color pixe density and mean flow velocity in mid-kidney cross-sectional regions of interest and the distance from the most peripheral color pixels to the capsule of the kidney. Other color Doppler quantitative methods have lacked reproducibility, and therefore before evaluation of the clinical usefulness of this technique, intraobserver reproducibility and interobserver reliability were assessed in 42 patients; no statistically significant variation was demonstrated. In 13 patients with normally functioning transplants, the mean maximum color pixel density was 34.7 +/- 13.4%, the mean flow velocity was 5.2 +/- 0.9 cm/second, and the mean distance to the capsule was 3.3 +/- 1.1 mm. (C) 2002 Wiley Periodicals, Inc.
引用
收藏
页码:151 / 157
页数:7
相关论文
共 12 条
[1]  
Akiyama T, 1996, TRANSPLANT P, V28, P1458
[2]   SEGMENTATION AND ANALYSIS OF COLOR DOPPLER IMAGES OF TUMOR VASCULATURE [J].
BELL, DS ;
BAMBER, JC ;
ECKERSLEY, RJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (05) :635-647
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   The 3D and 2D color flow display of breast masses [J].
Carson, PL ;
Moskalik, AP ;
Govil, A ;
Roubidoux, MA ;
Fowlkes, JB ;
Normolle, D ;
Adler, DD ;
Rubin, JM ;
Helvie, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (06) :837-849
[5]   Renal transplant evaluation with power Doppler sonography [J].
Hilborn, MD ;
Bude, RO ;
Murphy, KJ ;
Platt, JF ;
Rubin, JM .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 :39-42
[6]   BREAST-TUMORS - COMPUTER-ASSISTED QUANTITATIVE ASSESSMENT WITH COLOR DOPPLER US [J].
HUBER, S ;
DELORME, S ;
KNOPP, MV ;
JUNKERMANN, H ;
ZUNA, I ;
VONFOURNIER, D ;
VANKAICK, G .
RADIOLOGY, 1994, 192 (03) :797-801
[7]   AUTOMATED QUANTIFICATION OF COLOR DOPPLER SIGNALS - A PRELIMINARY-STUDY IN BREAST-TUMORS [J].
KEDAR, RP ;
COSGROVE, DO ;
BAMBER, JC ;
BELL, DS .
RADIOLOGY, 1995, 197 (01) :39-43
[8]  
Lu MD, 1999, J CLIN ULTRASOUND, V27, P319, DOI 10.1002/(SICI)1097-0096(199907/08)27:6<319::AID-JCU2>3.0.CO
[9]  
2-X
[10]   Interlobular vasculature in renal transplants: A power Doppler US study with MR correlation [J].
Martinoli, C ;
Crespi, G ;
Bertolotto, M ;
Rollandi, G ;
Rosenberg, I ;
Pretolesi, F ;
Derchi, LE .
RADIOLOGY, 1996, 200 (01) :111-117