Renal transplant evaluation with power Doppler sonography

被引:31
作者
Hilborn, MD [1 ]
Bude, RO [1 ]
Murphy, KJ [1 ]
Platt, JF [1 ]
Rubin, JM [1 ]
机构
[1] UNIV MICHIGAN,MED CTR,DEPT RADIOL,ANN ARBOR,MI 48109
关键词
D O I
10.1259/bjr.70.829.9059293
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was performed to determine if the marked variation we had previously noted in the power Doppler sonographic appearance of renal transplants correlated with disease. 22 renal transplants were scanned with power Doppler at 5 MHz, with biopsies being taken within 1 h in 17 kidneys and within 48 h in four other kidneys. Biopsy was not performed in one kidney with distal ureteral obstruction. Biopsy results were complex with many coexistent abnormalities; classification was based upon the predominant abnormality. Cortical vascularity was subjectively evaluated as normal, decreased or markedly decreased, and graded as 0, 1 or 2, respectively, and was compared with biopsy results, serum creatinine levels and resistive index. Cortical vascularity gradings were: 0 (12 cases); 1 (7 cases); and 2 (3 cases). The large number of disease categories (cellular rejection, 11 cases; vascular rejection, 5 cases; IgA nephropathy, 1 case; cyclosporin toxicity, 3 cases; obstruction, 1 case; and lupus nephropathy, 1 case) in relation to the number of vascular grades and number of kidneys precluded statistical analysis of cortical vascularity for rejection. However, vascularity did not appear to correlate with rejection, the three severest cases of vascular rejection having normal (grade 0) vascularity. There was no statistically significant correlation of vascular grade with creatinine levels or resistive index. In conclusion, subjective analysis of the power Doppler sonographic appearance of renal transplants does not appear to aid in their evaluation.
引用
收藏
页码:39 / 42
页数:4
相关论文
共 14 条
[1]  
BAXTER GM, 1995, CLIN RADIOL, V50, P618, DOI 10.1016/S0009-9260(05)83291-X
[2]   POWER VERSUS CONVENTIONAL COLOR DOPPLER SONOGRAPHY - COMPARISON IN THE DEPICTION OF NORMAL INTRARENAL VASCULATURE [J].
BUDE, RO ;
RUBIN, JM ;
ADLER, RS .
RADIOLOGY, 1994, 192 (03) :777-780
[3]  
GAINZA FJ, 1995, CLIN NEPHROL, V43, P303
[4]   DETECTION OF VASCULAR COMPLICATIONS IN RENAL-ALLOGRAFTS WITH COLOR DOPPLER FLOW IMAGING [J].
GRENIER, N ;
DOUWS, C ;
MOREL, D ;
FERRIERE, JM ;
LEGUILLOU, M ;
POTAUX, L ;
BROUSSIN, J .
RADIOLOGY, 1991, 178 (01) :217-223
[5]  
HELENON O, 1994, TRANSPLANT P, V26, P299
[6]  
MERKUS JWS, 1995, CLIN TRANSPLANT, V9, P383
[7]  
MONTSERRAT E, 1992, TRANSPLANT P, V24, P61
[8]   COMPARISON OF DUPLEX SONOGRAPHY AND COLOR DOPPLER IMAGING IN RENAL-ALLOGRAFT EVALUATION - A PROSPECTIVE-STUDY [J].
MOSTBECK, GH ;
REICHHALTER, C ;
STOCKENHUBER, F ;
POKIESER, P ;
MALLEK, R ;
WALTER, R ;
TSCHOLAKOFF, D .
EUROPEAN JOURNAL OF RADIOLOGY, 1990, 10 (03) :201-207
[9]   IMAGE-DIRECTED AND COLOR DOPPLER ULTRASONOGRAPHY IN THE DIAGNOSIS OF POSTBIOPSY ARTERIOVENOUS-FISTULAS OF NATIVE KIDNEYS [J].
OZBEK, SS ;
MEMIS, A ;
KILLI, R ;
KARACA, E ;
KABASAKAL, C ;
MIR, S .
JOURNAL OF CLINICAL ULTRASOUND, 1995, 23 (04) :239-242
[10]   RENAL-TRANSPLANT REJECTION - LIMITED VALUE OF DUPLEX DOPPLER SONOGRAPHY [J].
PERCHIK, JE ;
BAUMGARTNER, BR ;
BERNARDINO, ME .
INVESTIGATIVE RADIOLOGY, 1991, 26 (05) :422-426