Estimating the effective dose to children undergoing heart investigations - a phantom study

被引:20
作者
Axelsson, B
Khalil, C
Lidegran, M
Schuwert, P
Mortensson, W
机构
[1] Karolinska Inst, Dept Hosp Phys, S-17176 Stockholm, Sweden
[2] Karolinska Inst, Dept Paediat Radiol, S-17176 Stockholm, Sweden
关键词
D O I
10.1259/bjr.72.856.10474499
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the investigation was to assess the conversion factor (F) for derivation of effective dose from measured dose-area product (DAP) during radiological examination of congenital heart diseases. Two anthropomorphic phantoms corresponding to a 1-year-old and a 5-year-old child were irradiated at several projections to imitate irradiation conditions at heart examinations. Organ doses were measured using thermoluminescent dosimeters for calculation of mean organ doses and effective dose according to ICRP. DAP values were measured simultaneously. The conversion factor (F) was calculated from the ratio of effective dose (mSv) to DAP value (Gy cm(2)). The conversion factor (F) correlated strongly to the size of the phantom but less to the irradiation projection. However, at major beam angulation and at lateral projection F deviated note-worthily from that obtained at true or slightly angulated frontal views. Effective dose can therefore be estimated from the DAP values at heart investigation using two different F values. The following values are recommended for PA and lateral view respectively: for children weighing 7-11 kg, 1.8 and 1.4; for children weighing 15-26 kg 0.9 and 0.7.
引用
收藏
页码:378 / 383
页数:6
相关论文
共 21 条
[1]  
ALMCARLSSON GA, 1986, PHYS MED BIOL, V31, P911
[2]  
Almen A, 1996, ACTA RADIOL, V37, P337
[3]  
Almen A., 1996, Journal of Radiological Protection, V16, P81, DOI 10.1088/0952-4746/16/2/004
[4]   PATIENT EXPOSURES AND RADIATION RISKS IN SWEDISH DIAGNOSTIC RADIOLOGY [J].
BENGTSSON, G ;
BLOMGREN, PG ;
BERGMAN, K ;
ABERG, L .
ACTA RADIOLOGICA ONCOLOGY, 1978, 17 (02) :81-105
[5]   Radiation exposure to children during cardiac catheterization [J].
Boothroyd, A ;
McDonald, E ;
Moores, BM ;
Sluming, V ;
Carty, H .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 :180-185
[6]  
*COMM EUR COMM, 1997, 9743 CEC
[7]  
*COMM EUR COMM, 1996, 1621 CEC EUR
[8]   ACTIVE BONE-MARROW DISTRIBUTION AS A FUNCTION OF AGE IN HUMANS [J].
CRISTY, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (03) :389-400
[9]  
DREXLER G, 1993, RADIAT ENVIRON BIOPH, V2, P209
[10]   RADIATION-DOSES AND SOMATIC RISK TO PATIENTS DURING CARDIAC RADIOLOGICAL PROCEDURES [J].
FAULKNER, K ;
LOVE, HG ;
SWEENEY, JK ;
BARDSLEY, RA .
BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (700) :359-363