Spine detection in CT and MR using iterated marginal space learning

被引:85
作者
Kelm, B. Michael [1 ]
Wels, Michael [1 ]
Zhou, S. Kevin [2 ]
Seifert, Sascha [1 ]
Suehling, Michael [1 ]
Zheng, Yefeng [2 ]
Comaniciu, Dorin [2 ]
机构
[1] Siemens Corp Technol, Imaging & Comp Vis, Erlangen, Germany
[2] Siemens Corp Res & Technol, Imaging & Comp Vis, Princeton, NJ USA
关键词
Marginal space learning; Spine detection; Spinal disk segmentation; Vertebra segmentation; Generative-discriminative detection; ANATOMICAL STRUCTURES; VERTEBRA DETECTION; SCOLIOTIC SPINE; GRAPH CUTS; SEGMENTATION; LOCALIZATION; PIXEL; BIOMECHANICS; STATISTICS; FORESTS;
D O I
10.1016/j.media.2012.09.007
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Examinations of the spinal column with both, Magnetic Resonance (MR) imaging and Computed Tomography (CT), often require a precise three-dimensional positioning, angulation and labeling of the spinal disks and the vertebrae. A fully automatic and robust approach is a prerequisite for an automated scan alignment as well as for the segmentation and analysis of spinal disks and vertebral bodies in Computer Aided Diagnosis (CAD) applications. In this article, we present a novel method that combines Marginal Space Learning (MSL), a recently introduced concept for efficient discriminative object detection, with a generative anatomical network that incorporates relative pose information for the detection of multiple objects. It is used to simultaneously detect and label the spinal disks. While a novel iterative version of MSL is used to quickly generate candidate detections comprising position, orientation, and scale of the disks with high sensitivity, the anatomical network selects the most likely candidates using a learned prior on the individual nine dimensional transformation spaces. Finally, we propose an optional case-adaptive segmentation approach that allows to segment the spinal disks and vertebrae in MR and CT respectively. Since the proposed approaches are learning-based, they can be trained for MR or CT alike. Experimental results based on 42 MR and 30 CT volumes show that our system not only achieves superior accuracy but also is among the fastest systems of its kind in the literature. On the MR data set the spinal disks of a whole spine are detected in 11.5 s on average with 98.6% sensitivity and 0.073 false positive detections per volume. On the CT data a comparable sensitivity of 98.0% with 0.267 false positives is achieved. Detected disks are localized with an average position error of 2.4 mm/3.2 mm and angular error of 3.9 degrees/4.5 degrees in MR/CT, which is close to the employed hypothesis resolution of 2.1 mm and 3.3 degrees. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:1283 / 1292
页数:10
相关论文
共 49 条
[1]   Spine biomechanics [J].
Adams, MA ;
Dolan, P .
JOURNAL OF BIOMECHANICS, 2005, 38 (10) :1972-1983
[2]   Biomechanics of vertebral compression fractures and clinical application [J].
Adams, Michael A. ;
Dolan, Patricia .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (12) :1703-1710
[3]   Labeling of Lumbar Discs Using Both Pixel- and Object-Level Features With a Two-Level Probabilistic Model [J].
Alomari, Raja' S. ;
Corso, Jason J. ;
Chaudhary, Vipin .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (01) :1-10
[4]  
[Anonymous], 2001, The elements of statistical learning: data mining, inference and prediction
[5]   Geometric variability of the scoliotic spine using statistics on articulated shape models [J].
Boisvert, Jonathan ;
Cheriet, Farida ;
Pennec, Xavier ;
Labelle, Hubert ;
Ayache, Nicholas .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (04) :557-568
[6]   Graph cuts and efficient N-D image segmentation [J].
Boykov, Yuri ;
Funka-Lea, Gareth .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 2006, 70 (02) :109-131
[7]   Random forests [J].
Breiman, L .
MACHINE LEARNING, 2001, 45 (01) :5-32
[8]   Automatic ovarian follicle quantification from 3D ultrasound data using global/local context with database guided segmentation [J].
Chen, Terrence ;
Zhang, Wei ;
Good, Sara ;
Zhou, Kevin S. ;
Comaniciu, Dorin .
2009 IEEE 12TH INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV), 2009, :795-802
[9]  
Corso JJ, 2008, LECT NOTES COMPUT SC, V5241, P202, DOI 10.1007/978-3-540-85988-8_25
[10]   Quantification of spinal cord atrophy from magnetic resonance images via a B-spline active surface model [J].
Coulon, O ;
Hickman, SJ ;
Parker, GJ ;
Barker, GJ ;
Miller, DH ;
Arridge, SR .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1176-1185