Spine detection in CT and MR using iterated marginal space learning

被引:85
作者
Kelm, B. Michael [1 ]
Wels, Michael [1 ]
Zhou, S. Kevin [2 ]
Seifert, Sascha [1 ]
Suehling, Michael [1 ]
Zheng, Yefeng [2 ]
Comaniciu, Dorin [2 ]
机构
[1] Siemens Corp Technol, Imaging & Comp Vis, Erlangen, Germany
[2] Siemens Corp Res & Technol, Imaging & Comp Vis, Princeton, NJ USA
关键词
Marginal space learning; Spine detection; Spinal disk segmentation; Vertebra segmentation; Generative-discriminative detection; ANATOMICAL STRUCTURES; VERTEBRA DETECTION; SCOLIOTIC SPINE; GRAPH CUTS; SEGMENTATION; LOCALIZATION; PIXEL; BIOMECHANICS; STATISTICS; FORESTS;
D O I
10.1016/j.media.2012.09.007
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Examinations of the spinal column with both, Magnetic Resonance (MR) imaging and Computed Tomography (CT), often require a precise three-dimensional positioning, angulation and labeling of the spinal disks and the vertebrae. A fully automatic and robust approach is a prerequisite for an automated scan alignment as well as for the segmentation and analysis of spinal disks and vertebral bodies in Computer Aided Diagnosis (CAD) applications. In this article, we present a novel method that combines Marginal Space Learning (MSL), a recently introduced concept for efficient discriminative object detection, with a generative anatomical network that incorporates relative pose information for the detection of multiple objects. It is used to simultaneously detect and label the spinal disks. While a novel iterative version of MSL is used to quickly generate candidate detections comprising position, orientation, and scale of the disks with high sensitivity, the anatomical network selects the most likely candidates using a learned prior on the individual nine dimensional transformation spaces. Finally, we propose an optional case-adaptive segmentation approach that allows to segment the spinal disks and vertebrae in MR and CT respectively. Since the proposed approaches are learning-based, they can be trained for MR or CT alike. Experimental results based on 42 MR and 30 CT volumes show that our system not only achieves superior accuracy but also is among the fastest systems of its kind in the literature. On the MR data set the spinal disks of a whole spine are detected in 11.5 s on average with 98.6% sensitivity and 0.073 false positive detections per volume. On the CT data a comparable sensitivity of 98.0% with 0.267 false positives is achieved. Detected disks are localized with an average position error of 2.4 mm/3.2 mm and angular error of 3.9 degrees/4.5 degrees in MR/CT, which is close to the employed hypothesis resolution of 2.1 mm and 3.3 degrees. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:1283 / 1292
页数:10
相关论文
共 49 条
[31]  
Peng Z, 2006, ENG MED BIOL SOC 200, P2527
[32]   Intrinsic statistics on riemannian manifolds: Basic tools for geometric measurements [J].
Pennec, Xavier .
JOURNAL OF MATHEMATICAL IMAGING AND VISION, 2006, 25 (01) :127-154
[33]  
Schmidt S, 2007, LECT NOTES COMPUT SC, V4584, P122
[34]  
Seifert S., 2010, P SPIE MED IMAGING
[35]  
Seifert S., 2009, P SPIE MED IMAGING, P725
[36]   Biomechanical modeling of the cervical spine on the basis of tomographic data [J].
Seifert, Sascha ;
Dillimann, Ruediger .
BIOMEDIZINISCHE TECHNIK, 2007, 52 (05) :337-345
[37]  
Shaolei Feng, 2009, 2009 IEEE Conference on Computer Vision and Pattern Recognition (CVPR), P2488, DOI 10.1109/CVPRW.2009.5206527
[38]  
Sofka M, 2011, I S BIOMED IMAGING, P294, DOI 10.1109/ISBI.2011.5872409
[39]   Biomechanics of vertebral level, geometry, and transcortical tumors in the metastatic spine [J].
Tschirhart, Craig E. ;
Finkelstein, Joel A. ;
Whyne, Cari M. .
JOURNAL OF BIOMECHANICS, 2007, 40 (01) :46-54
[40]   Brain anatomical structure segmentation by hybrid discriminative/generative models [J].
Tu, Zhuowen ;
Narr, Katherine L. ;
Dollar, Piotr ;
Dinov, Ivo ;
Thompson, Paul M. ;
Toga, Arthur W. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (04) :495-508