Carmeli's S index assesses motion and muscle artefact reduction in rowers' electrocardiograms

被引:6
作者
Celka, Patrick
Kilner, Brett
机构
[1] Griffith Univ, Sch Engn, Southport, Qld 4215, Australia
[2] Ericsson Telecom AB, Sydney, NSW, Australia
关键词
noise reduction; electrocardiogram; electromyogram; adaptive algorithm; synchronization; state space;
D O I
10.1088/0967-3334/27/8/008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Electrocardiograms (ECG) suffer high perturbations from motion and muscle activities when measured on the chest of rowers. However, for cardiac assessment and sport performance measures, ECG complexes and their time occurrences contain information of great value. We thus propose to use electromyogram (EMG) sensors placed on the distal pectoral muscle to provide a reference signal for motion and muscle activity cancellation. The low frequencies of the EMG signal are conserved for motion cancellation. A combination of band-pass and adaptive filters allows us to recover ECG complexes. This specific scheme is intended to be used for advanced ECG sensors with on-board digital signal processing which requires low-power electronics. A validation of the method is performed based on a nonlinear dynamic model of the ECG and linear frequency modulated rowing movement for various input and output signal-to-noise ratios and adaptive filter gain parameters. Results show a good motion tracking cancellation of the adaptive filter. Finally, assessments of the method on the real recorded data from five subjects are presented. To this end, we have first computed estimates of the signal-to-noise ratio gain between the original and noise-reduced signals. Second, we have developed a modified synchronization index first proposed by Carmeli et al between a QRS template and the original and noise-reduced signals. Both assessment measures are complementary to each other.
引用
收藏
页码:737 / 755
页数:19
相关论文
共 33 条
[1]   ECG beat detection using filter banks [J].
Afonso, VX ;
Tompkins, WJ ;
Nguyen, TQ ;
Luo, S .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (02) :192-202
[2]  
ALDROUBI A, 1996, WAVELETS MED BIOL
[3]   Wigner functions from the two-dimensional wavelet group [J].
Ali, ST ;
Krasowska, AE ;
Murenzi, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2000, 17 (12) :2277-2287
[4]  
Ali ST., 2000, GRAD TEXT C
[5]  
[Anonymous], 2003, ELECTROACTIVE FABRIC
[6]  
[Anonymous], 1989, COMPUTERS CARDIOLOGY
[7]  
[Anonymous], NONLINEAR SCI SERIES
[8]   Galilean wavelets: Coherent states of the affine Galilei group [J].
Antoine, JP ;
Mahara, I .
JOURNAL OF MATHEMATICAL PHYSICS, 1999, 40 (11) :5956-5971
[9]   ESTIMATING AND INTERPRETING THE INSTANTANEOUS FREQUENCY OF A SIGNAL .1. FUNDAMENTALS [J].
BOASHASH, B .
PROCEEDINGS OF THE IEEE, 1992, 80 (04) :520-538
[10]   Assessment of EEG synchronization based on state-space analysis [J].
Carmeli, C ;
Knyazeva, MG ;
Innocenti, GM ;
De Feo, O .
NEUROIMAGE, 2005, 25 (02) :339-354