Is there an alternative to systemic anticoagulation, as related to interventional biomedical devices?

被引:30
作者
Conn, Gemma
Kidane, Asmeret G.
Punshon, Geoffrey
Kannan, Ruben Y.
Hamilton, George
Seifalian, Alexander M.
机构
[1] UCL, Biomat & Tissue Engn Ctr, Acad Div Surg & Intervent Sci, London NW3 2PF, England
[2] Royal Free Hampstead NHS Trust, Vasc Unit, London NW3 2PF, England
关键词
anticoagulant; antiplatelet; cardiovascular bypass graft; catheter; extracorporeal circuit; guide wire; heparin; stent; tissue engineering;
D O I
10.1586/17434440.3.2.245
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To reduce the toxic effects, related clinical problems and complications such as bleeding disorders associated with systemic anticoagulation, it has been hypothesized that by coating the surfaces of medical devices, such as stents, bypass grafts, extracorporeal circuits, guide wires and catheters, there will be a significant reduction in the requirement for systemic anticoagulation or, ideally, it will no longer be necessary. However, current coating processes, even covalent ones, still result in leaching followed by reduced functionality. Alternative anticoagulants and related antiplatelet agents have been used for improvement in terms of reduced restenosis, intimal hyperphasia and device failure. This review focuses on existing heparinization processes, their application in clinical devices and the updated list of alternatives to heparinization in order to obtain a broad overview, it then highlights, in particular, the future possibilities of using heparin and related moieties to tissue engineer scaffolds.
引用
收藏
页码:245 / 261
页数:17
相关论文
共 175 条
[41]   The role of recombinant hirudins in the management of thrombotic disorders [J].
Fischer, KG .
BIODRUGS, 2004, 18 (04) :235-268
[42]  
Foley PL, 2002, COMPARATIVE MED, V52, P243
[43]   Duraflo II coating of cardiopulmonary bypass circuits reduces complement activation, but does not affect the release of granulocyte enzymes in fully heparinized patients: A European multicentre study [J].
Fosse, E ;
Thelin, S ;
Svennevig, JL ;
Jansen, P ;
Mollnes, TE ;
Hack, E ;
Venge, P ;
Moen, O ;
Brockmeier, V ;
Dregelid, E ;
Halden, E ;
Hagman, L ;
Videm, V ;
Pedersen, T ;
Mohr, B .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 11 (02) :320-327
[44]   Acute and mid-term results of phosphorylcholine-coated stents in primary coronary stenting for acute myocardial infarction [J].
Galli, M ;
Sommariva, L ;
Prati, F ;
Zerboni, S ;
Politi, A ;
Bonatti, R ;
Mameli, S ;
Butti, E ;
Pagano, A ;
Ferrari, G .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 53 (02) :182-187
[45]  
GALLI M, 2000, J INVASIVE CARDIOL, V452
[46]   IMPROVEMENT IN EARLY SAPHENOUS-VEIN GRAFT PATENCY AFTER CORONARY-ARTERY BYPASS-SURGERY WITH ANTIPLATELET THERAPY - RESULTS OF A VETERANS ADMINISTRATION COOPERATIVE STUDY [J].
GOLDMAN, S ;
COPELAND, J ;
MORITZ, T ;
HENDERSON, W ;
ZADINA, K ;
OVITT, T ;
DOHERTY, J ;
READ, R ;
CHESLER, E ;
SAKO, Y ;
LANCASTER, L ;
EMERY, R ;
SHARMA, GVRK ;
JOSA, M ;
PACOLD, I ;
MONTOYA, A ;
PARIKH, D ;
SETHI, G ;
HOLT, J ;
KIRKLIN, J ;
SHABETAI, R ;
MOORES, W ;
ALDRIDGE, J ;
MASUD, Z ;
DEMOTS, H ;
FLOTEN, S ;
HAAKENSON, C ;
HARKER, LA .
CIRCULATION, 1988, 77 (06) :1324-1332
[47]   Surface-bound heparin fails to reduce thrombin formation during clinical cardiopulmonary bypass [J].
Gorman, RC ;
Ziats, NP ;
Rao, AK ;
Gikakis, N ;
Sun, L ;
Khan, MMH ;
Stenach, N ;
Sapatnekar, S ;
Chouhan, V ;
Gorman, JH ;
Niewiarowski, S ;
Colman, RW ;
Anderson, JM ;
Edmunds, LH .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (01) :1-11
[48]   ePTFE coating with fibrin glue, FGF-1, and heparin: Effect on retention of seeded endothelial cells [J].
Gosselin, C ;
Vorp, DA ;
Warty, V ;
Severyn, DA ;
Dick, EK ;
Borovetz, HS ;
Greisler, HP .
JOURNAL OF SURGICAL RESEARCH, 1996, 60 (02) :327-332
[49]   IN-VIVO PLATELET DEPOSITION ON POLYTETRAFLUOROETHYLENE COATED WITH FIBRIN GLUE CONTAINING FIBROBLAST GROWTH-FACTOR-1 AND HEPARIN IN A CANINE MODEL [J].
GOSSELIN, C ;
REN, DW ;
ELLINGER, J ;
GREISLER, HP .
AMERICAN JOURNAL OF SURGERY, 1995, 170 (02) :126-130
[50]  
GOTT VL, 1963, SCIENCE, V142, P1297, DOI 10.1126/science.142.3597.1297