Fretting corrosion characteristics of polished collarless tapered stems in a simulated biological environment

被引:15
作者
Bryant, Michael [1 ]
Farrar, Richard [2 ]
Freeman, Robert [2 ]
Brummitt, Ken [2 ]
Neville, Anne [1 ]
机构
[1] Univ Leeds, Inst Engn Thermofluids Surfaces & Interfaces, Leeds LS2 9JT, W Yorkshire, England
[2] DePuy Int, Leeds, W Yorkshire, England
关键词
Fretting-corrosion; Biomedical; Femoral stem; Depassivation; TOTAL HIP-REPLACEMENT; IONS IN-VITRO; ORTHOPEDIC IMPLANTS; SURFACE FINISH; CHROMIUM IONS; FEMORAL STEM; METAL; COBALT; APOPTOSIS; STRENGTH;
D O I
10.1016/j.triboint.2013.01.024
中图分类号
TH [机械、仪表工业];
学科分类号
120111 [工业工程];
摘要
The role fretting-corrosion plays on the degradation and formation of debris within the stem cement interface was investigated. Electrochemical measurements of potential and polarisation resistance, along with solution mass spectroscopy were employed. Optical, Scanning Electron and Transmission Electron Microscopy with Energy Dispersive X-Ray Spectroscopy techniques were utilised to observe surface morphology after fretting-corrosion tests. Electrochemical measurements indicated dynamic loading resulted in de-passivation of the metallic surface. Solution mass spectroscopy indicted high concentrations of cobalt were released from the interface, accounting for 94% of all metallic ions released into the environment. Detailed imagery of fretting-corrosion product indicated a chromium and oxygen layer on the metallic and bone cement surface owing to the electrochemical stability of species released as a result of fretting-corrosion. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:105 / 112
页数:8
相关论文
共 36 条
[1]
[Anonymous], 1995, An introduction to metallurgy
[2]
The basic science of periprosthetic osteolysis [J].
Archibeck, MJ ;
Jacobs, JJ ;
Roebuck, KA ;
Glant, TT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (10) :1478-1489
[3]
What results in fretting wear on polished femoral stems [J].
Blunt, Liam A. ;
Zhang, H. ;
Barrans, Simon M. ;
Jiang, X. ;
Brown, Leigh T. .
TRIBOLOGY INTERNATIONAL, 2009, 42 (11-12) :1605-1614
[4]
High failure rates with a large-diameter hybrid metal-on-metal total hip replacement CLINICAL, RADIOLOGICAL AND RETRIEVAL ANALYSIS [J].
Bolland, B. J. R. F. ;
Culliford, D. J. ;
Langton, D. J. ;
Millington, J. P. S. ;
Arden, N. K. ;
Latham, J. M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (05) :608-615
[5]
Quantitative analysis of macrophage apoptosis vs. necrosis induced by cobalt and chromium ions in vitro [J].
Catelas, I ;
Petit, A ;
Vali, H ;
Fragiskatos, C ;
Meilleur, R ;
Zukor, DJ ;
Antoniou, J ;
Huk, OL .
BIOMATERIALS, 2005, 26 (15) :2441-2453
[6]
TNF-α secretion and macrophage mortality induced by cobalt and chromium ions in vitro-Qualitative analysis of apoptosis [J].
Catelas, I ;
Petit, A ;
Zukor, DJ ;
Antoniou, J ;
Huk, OL .
BIOMATERIALS, 2003, 24 (03) :383-391
[7]
METAL-ION RELEASE AFTER TOTAL HIP-REPLACEMENT [J].
DOBBS, HS ;
MINSKI, MJ .
BIOMATERIALS, 1980, 1 (04) :193-198
[8]
Early failure of the Ultima metal-on-metal total hip replacement in the presence of normal plain radiographs [J].
Donell, S. T. ;
Darrah, C. ;
Nolan, J. F. ;
Wimhurst, J. ;
Toms, A. ;
Barker, T. H. W. ;
Case, C. P. ;
Tucker, J. K. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (11) :1501-1508
[9]
FLIS J, 1995, J APPL ELECTROCHEM, V25, P501
[10]
Fontanna M. G., 1978, CORROSION ENG