Microelectrode array fabricated in low temperature cofired ceramic (LTCC) technology

被引:13
作者
Ciosek, Patrycja [1 ]
Zawadzki, Konrad [1 ]
Stadnik, Dorota [2 ]
Bembnowicz, Pawel [3 ]
Golonka, Leszek [3 ]
Wroblewski, Wojciech [1 ]
机构
[1] Warsaw Univ Technol, Dept Analyt Chem, PL-00664 Warsaw, Poland
[2] Inst Biotechnol & Antibiot, Dept Chem Anal, PL-02516 Warsaw, Poland
[3] Wroclaw Univ Technol, Fac Microsyst Elect & Photon, PL-50370 Wroclaw, Poland
关键词
Electronic tongue; Microelectrode array; LTCC technology; POTENTIOMETRIC ELECTRONIC TONGUE; SENSOR ARRAYS; RECOGNITION; SYSTEM; BEVERAGES;
D O I
10.1007/s10008-008-0571-x
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This work presents the development of a novel construction of an integrated microelectrode array. The device was fabricated on a ceramic support, with the use of low temperature cofired ceramics technology. Model potassium-selective membranes were applied on the surface of PdAg/AgCl electrodes formed on the ceramic substrate. The obtained microsensors exhibited very good repeatability, reproducibility, and sensitivity. The array of microelectrodes covered with polymeric layers of various selectivities was applied as an electronic tongue to differentiate between various diet supplements.
引用
收藏
页码:129 / 135
页数:7
相关论文
共 22 条
[1]   Cross-reactive chemical sensor arrays [J].
Albert, KJ ;
Lewis, NS ;
Schauer, CL ;
Sotzing, GA ;
Stitzel, SE ;
Vaid, TP ;
Walt, DR .
CHEMICAL REVIEWS, 2000, 100 (07) :2595-2626
[2]   Improved multianalyte detection of organophosphates and carbamates with disposable multielectrode biosensors using recombinant mutants of Drosophila acetylcholinesterase and artificial neural networks [J].
Bachmann, TT ;
Leca, B ;
Vilatte, F ;
Marty, JL ;
Fournier, D ;
Schmid, RD .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (3-4) :193-201
[3]  
CHUDY M, 2006, P SPIE
[4]   Polymeric membrane ion-selective and cross-sensitive electrode-based electronic tongue for qualitative analysis of beverages [J].
Ciosek, P ;
Augustyniak, E ;
Wróblewski, W .
ANALYST, 2004, 129 (07) :639-644
[5]  
CIOSEK P, 2007, P INT S OLF EL NOS P
[6]   Analysis of dialysate fluids with the use of a potentiometric electronic tongue [J].
Ciosek, Patrycja ;
Grabowska, Ilona ;
Brzozka, Zbigniew ;
Wroblewski, Wojciech .
MICROCHIMICA ACTA, 2008, 163 (1-2) :139-145
[7]   Potentiometric electronic tongue based on integrated array of microelectrodes [J].
Ciosek, Patrycja ;
Maminska, Renata ;
Dybko, Artur ;
Wroblewski, Wojciech .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 127 (01) :8-14
[8]   Sensor arrays for liquid sensing -: electronic tongue systems [J].
Ciosek, Patrycja ;
Wroblewski, Wojciech .
ANALYST, 2007, 132 (10) :963-978
[9]   Electronic tongue for flow-through analysis of beverages [J].
Ciosek, Patrycja ;
Brzozka, Zbigniew ;
Wroblewski, Wojciech .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 118 (1-2) :454-460
[10]   The recognition of growth conditions and metabolic type of plants by a potentiometric electronic tongue [J].
Ciosek, Patrycja ;
Pokorska, Berenika ;
Romanowska, Elzbieta ;
Wroblewski, Wojciech .
ELECTROANALYSIS, 2006, 18 (13-14) :1266-1272