A new approach for non-intrusive monitoring of blood pressure on a toilet seat

被引:43
作者
Kim, JS [1 ]
Chee, YJ
Park, JW
Choi, JW
Park, KS
机构
[1] Seoul Natl Univ, Interdisciplinary Program Biomed Engn, Seoul, South Korea
[2] Seoul Natl Univ, Adv Biometr Res Ctr, Seoul, South Korea
[3] Seoul Natl Univ, Dept Biomed Engn, Coll Med, Seoul, South Korea
关键词
pulse arrival time; PPG; blood pressure; toilet seat;
D O I
10.1088/0967-3334/27/2/010
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Pulse arrival time (PAT) was measured non-intrusively to estimate each individual's blood pressure. Electrocardiogram (ECG) was measured with copper-coated electrodes and photoplethysmogram (PPG) was measured using a specially designed toilet seat apparatus. Non-intrusively measured PATs were compared with PATs measured by the standard method, and the results showed a good correlation. An equation was used to estimate blood pressure from the measured PAT during a training period for each individual. Estimated blood pressures were compared with measured blood pressures in a series of blood pressure varying experiments. For each individual, the estimated blood pressure was similar to the measured blood pressure within a tolerable error range. This method was also practiced for long-term monitoring, and the results show the value of this method for continuous home monitoring of blood pressure.
引用
收藏
页码:203 / 211
页数:9
相关论文
共 18 条
[1]   THE COVARIATION OF BLOOD-PRESSURE AND PULSE TRANSIT-TIME IN HYPERTENSIVE PATIENTS [J].
ALLEN, RA ;
SCHNEIDER, JA ;
DAVIDSON, DM ;
WINCHESTER, MA ;
TAYLOR, CB .
PSYCHOPHYSIOLOGY, 1981, 18 (03) :301-306
[2]   Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients [J].
Blacher, J ;
Asmar, R ;
Djane, S ;
London, GM ;
Safar, ME .
HYPERTENSION, 1999, 33 (05) :1111-1117
[3]   DETERMINATION OF PULSE-WAVE VELOCITIES WITH COMPUTERIZED ALGORITHMS [J].
CHIU, YC ;
ARAND, PW ;
SHROFF, SG ;
FELDMAN, T ;
CARROLL, JD .
AMERICAN HEART JOURNAL, 1991, 121 (05) :1460-1470
[4]   PULSE TRANSIT-TIME FEEDBACK AND BIDIRECTIONAL BLOOD-PRESSURE CHANGE [J].
CINCIRIPINI, PM ;
EPSTEIN, LH .
PSYCHOPHYSIOLOGY, 1981, 18 (06) :630-634
[5]   Relation between heart rate and pulse transit time during paced respiration [J].
Drinnan, MJ ;
Allen, J ;
Murray, A .
PHYSIOLOGICAL MEASUREMENT, 2001, 22 (03) :425-432
[6]   PULSE TRANSIT-TIME AS AN INDICATOR OF ARTERIAL BLOOD-PRESSURE [J].
GEDDES, LA ;
VOELZ, MH ;
BABBS, CF ;
BOURLAND, JD ;
TACKER, WA .
PSYCHOPHYSIOLOGY, 1981, 18 (01) :71-74
[7]   PULSE TRANSIT-TIME AND BLOOD-PRESSURE - AN INTENSIVE ANALYSIS [J].
LANE, JD ;
GREENSTADT, L ;
SHAPIRO, D ;
RUBINSTEIN, E .
PSYCHOPHYSIOLOGY, 1983, 20 (01) :45-49
[8]   THE RELATIONSHIP BETWEEN ARTERIAL BLOOD-PRESSURE AND PULSE TRANSIT-TIME DURING DYNAMIC AND STATIC EXERCISE [J].
MARIE, GV ;
LO, CR ;
VANJONES, J ;
JOHNSTON, DW .
PSYCHOPHYSIOLOGY, 1984, 21 (05) :521-527
[9]   The difference in pulse transit time to the toe and finger measured by photoplethysmography [J].
Nitzan, M ;
Khanokh, B ;
Slovik, Y .
PHYSIOLOGICAL MEASUREMENT, 2002, 23 (01) :85-93
[10]   PULSE TRANSIT-TIME - RELATIONSHIP TO BLOOD-PRESSURE AND MYOCARDIAL PERFORMANCE [J].
OBRIST, PA ;
LIGHT, KC ;
MCCUBBIN, JA ;
HUTCHESON, JS ;
HOFFER, JL .
PSYCHOPHYSIOLOGY, 1979, 16 (03) :292-301