On-line two-dimensional capillary strong anion exchange/reversed phase liquid chromatography-tandem mass spectrometry for comprehensive lipid analysis

被引:38
作者
Bang, Dae Young [1 ,2 ]
Moon, Myeong Hee [1 ]
机构
[1] Yonsei Univ, Dept Chem, Seoul 120749, South Korea
[2] Lotte R&D Ctr, Seoul 150194, South Korea
基金
新加坡国家研究基金会;
关键词
Two-dimensional chromatography; SAX/RPLC; 2D LC-MS; Lipidomics; Tandem mass spectrometry; HUMAN PLASMA; PHOSPHOLIPID CLASSES; SEPARATION; LYSOPHOSPHOLIPIDS; BRAIN; MS; PHOSPHATIDYLCHOLINES; TRIACYLGLYCEROLS; QUANTITATION; EXTRACTION;
D O I
10.1016/j.chroma.2013.08.069
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
An on-line two-dimensional liquid chromatography method was developed for comprehensive lipid profiling by coupling strong anion exchange (SAX) and nanoflow reversed-phase liquid chromatography (nRPLC) prior to electrospray ionization-tandem mass spectrometry (2D-SAX/nRPLC-ESI-MS/MS). Lipids can be classified into four different types according to the electrical propensities of the lipids: anionic, weak anionic, neutral polar, and special lipids. In 2D-SAX/nRPLC, various lipids can be fractionated in the first dimension (SAX: 5 mu m to 100 angstrom, 5.0 cm x 75 mu m i.d.) by step elution (methanol and salt solution), followed by the molecular separation of lipids in the second dimension (RP: 3 mu m to 100 angstrom, 7.0 cm x 75 mu m i.d.) with binary gradient LC. Since the elution of lipids from SAX can be achieved with a very small volume of eluent delivered from an autosampler, it can be simply implemented with an LC-ESI-MS instrument for full automation, and the salt step elution, including the two-step injection procedure, can be used for the selective analysis of the desired lipid fraction. For nRPLC-ESI-MS/MS run in either positive or negative ion mode, a common ionization modifier (0.05% ammonium hydroxide with 5 mM ammonium formate) was introduced into the binary mobile phase solutions so that 2D-LC-MS could be operated in both ion modes without changing the mobile phase solutions. The developed on-line 2D-SAX/nRPLC-ESI-MS/MS was evaluated with 22 different standard lipids for the optimization of the salt step elution and was applied to a healthy human plasma lipid extract, resulting in the identification of a total of 303 plasma lipids, including 14 different classes. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:82 / 90
页数:9
相关论文
共 38 条
[1]
Determination of phospholipids in dairy products by SPE/HPLU/ELSD [J].
Avalli, A ;
Contarini, G .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1071 (1-2) :185-190
[2]
Shotgun analysis of phospholipids from mouse liver and brain by nanoflow liquid chromatography/tandem mass spectrometry [J].
Bang, Dae Young ;
Ahn, Eun jeong ;
Moon, Myeong Hee .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2) :268-277
[3]
Effect of ionization modifiers on the simultaneous analysis of all classes of phospholipids by nanoflow liquid chromatography/tandem mass spectrometry in negative ion mode [J].
Bang, Dae Young ;
Lim, Sangsoo ;
Moon, Myeong Hee .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1240 :69-76
[4]
Nanoflow liquid chromatography-tandem mass spectrometry for the characterization of intact phosphatidylcholines from soybean, bovine brain, and liver [J].
Bang, DY ;
Kang, DJ ;
Moon, MH .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1104 (1-2) :222-229
[5]
HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF PHOSPHOLIPIDS FROM DIFFERENT SOURCES WITH COMBINED FLUORESCENCE AND ULTRAVIOLET DETECTION [J].
BERNHARD, W ;
LINCK, M ;
CREUTZBURG, H ;
POSTLE, AD ;
ARNING, A ;
MARTINCARRERA, I ;
SEWING, KF .
ANALYTICAL BIOCHEMISTRY, 1994, 220 (01) :172-180
[6]
Optimized extraction of phospholipids and lysophospholipids for nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry [J].
Byeon, Seul Kee ;
Lee, Ju Yong ;
Moon, Myeong Hee .
ANALYST, 2012, 137 (02) :451-458
[7]
Application of the accurate mass and time tag approach in studies of the human blood lipidome [J].
Ding, Jie ;
Sorensen, Christina M. ;
Jaitly, Navdeep ;
Jiang, Hongliang ;
Orton, Daniel J. ;
Monroe, Matthew E. ;
Moore, Ronald J. ;
Smith, Richard D. ;
Metz, Thomas O. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 871 (02) :243-252
[8]
Comprehensive two-dimensional liquid chromatography combined with mass spectrometric detection in the analyses of triacylglycerols in natural lipidic matrixes [J].
Dugo, P ;
Kumm, T ;
Crupi, ML ;
Cotroneo, A ;
Mondello, L .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1112 (1-2) :269-275
[9]
Separation of triacylglycerols in a complex lipidic matrix by using comprehensive two-dimensional liquid chromatography coupled with atmospheric pressure chemical ionization mass spectrometric detection [J].
Dugo, Paola ;
Kumm, Tiina ;
Chiofalo, Biagina ;
Cotroneo, Antonella ;
Mondello, Luigi .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (08) :1146-1154
[10]
A comprehensive classification system for lipids [J].
Fahy, E ;
Subramaniam, S ;
Brown, HA ;
Glass, CK ;
Merrill, AH ;
Murphy, RC ;
Raetz, CRH ;
Russell, DW ;
Seyama, Y ;
Shaw, W ;
Shimizu, T ;
Spener, F ;
van Meer, G ;
VanNieuwenhze, MS ;
White, SH ;
Witztum, JL ;
Dennis, EA .
JOURNAL OF LIPID RESEARCH, 2005, 46 (05) :839-861