Optimization of electrochemical aptamer-based sensors via optimization of probe packing density and surface chemistry

被引:275
作者
White, Ryan J. [1 ]
Phares, Noelle [1 ]
Lubin, Arica A. [1 ]
Xiao, Yi [1 ]
Plaxco, Kevin W. [1 ,2 ]
机构
[1] Univ Calif Santa Barbara, Dept Chem & Biochem, Santa Barbara, CA 93106 USA
[2] Univ Calif Santa Barbara, Interdept Program Biomol Sci & Engn, Santa Barbara, CA 93106 USA
关键词
D O I
10.1021/la800801v
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electrochemical, aptamer-based (E-AB) sensors, which are comprised of an electrode modified with surface immobilized, redox-tagged DNA aptamers, have emerged as a promising new biosensor platform. In order to further improve this technology we have systematically studied the effects of probe (aptamer) packing density, the AC frequency used to interrogate the sensor, and the nature of the self-assembled monolayer (SAM) used to passivate the electrode on the performance of representative E-AB sensors directed against the small molecule cocaine and the protein thrombin. We find that, by controlling the concentration of aptamer employed during sensor fabrication, we can control the density of probe DNA molecules on the electrode surface over an order of magnitude range. Over this range, the gain of the cocaine sensor varies from 60% to 200%, with maximum gain observed near the lowest probe densities. In contrast, over a similar range, the signal change of the thrombin sensor varies from 16% to 42% and optimal signaling is observed at intermediate densities. Above cut-offs at low hertz frequencies, neither sensor displays any significant dependence on the frequency of the alternating potential employed in their interrogation. Finally, we find that E-AB signal gain is sensitive to the nature of the alkanethiol SAM employed to passivate the interrogating electrode; while thinner SAMs lead to higher absolute sensor currents, reducing the length of the SAM from 6-carbons to 2-carbons reduces the observed signal gain of our cocaine sensor 10-fold. We demonstrate that fabrication and operational parameters can be varied to achieve optimal sensor performance and that these can serve as a basic outline for future sensor fabrication.
引用
收藏
页码:10513 / 10518
页数:6
相关论文
共 33 条
[1]  
Baker BR, 2006, J AM CHEM SOC, V128, P3138, DOI 10.1021/ja056957p
[2]  
F Allen J Bard L.R., 2001, Electrochemical Methods: Fundamentals and Applications
[3]   Biosensors based on binding-modulated donor-acceptor distances [J].
Fan, CH ;
Plaxco, KW ;
Heeger, AJ .
TRENDS IN BIOTECHNOLOGY, 2005, 23 (04) :186-192
[4]   An RNA aptamer-based electrochemical biosensor for detection of theophylline in serum [J].
Ferapontova, Elena E. ;
Olsen, Eva M. ;
Gothelf, Kurt V. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (13) :4256-+
[5]   Brush effects on DNA chips: thermodynamics, kinetics, and design guidelines [J].
Halperin, A ;
Buhot, A ;
Zhulina, EB .
BIOPHYSICAL JOURNAL, 2005, 89 (02) :796-811
[6]   Characterization of DNA probes immobilized on gold surfaces [J].
Herne, TM ;
Tarlov, MJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (38) :8916-8920
[7]   Towards integrated and sensitive surface plasmon resonance biosensors: A review of recent progress [J].
Hoa, X. D. ;
Kirk, A. G. ;
Tabrizian, M. .
BIOSENSORS & BIOELECTRONICS, 2007, 23 (02) :151-160
[8]   Orienting DNA helices on gold using applied electric fields [J].
Kelley, SO ;
Barton, JK ;
Jackson, NM ;
McPherson, LD ;
Potter, AB ;
Spain, EM ;
Allen, MJ ;
Hill, MG .
LANGMUIR, 1998, 14 (24) :6781-6784
[9]   Aptamer-based electrochemical detection of picomolar platelet-derived growth factor directly in blood serum [J].
Lai, Rebecca Y. ;
Plaxco, Kevin W. ;
Heeger, Alan J. .
ANALYTICAL CHEMISTRY, 2007, 79 (01) :229-233
[10]   Electrochemical interrogation of DNA monolayers on gold surfaces [J].
Lao, RJ ;
Song, SP ;
Wu, HP ;
Wang, LH ;
Zhang, ZZ ;
He, L ;
Fan, CH .
ANALYTICAL CHEMISTRY, 2005, 77 (19) :6475-6480