A technique for adaptive image-guided helical tomotherapy for lung cancer

被引:129
作者
Ramsey, CR
Langen, KM
Kupelian, PA
Scaperoth, DD
Meeks, SL
Mahan, SL
Seibert, RM
机构
[1] Thompson Canc survival Ctr, Dept Radiat Oncol, Knoxville, TN 37916 USA
[2] MD Anderson Canc Ctr, Dept Radiat Oncol, Orlando, FL USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2006年 / 64卷 / 04期
关键词
lung; image-guided radiation therapy; helical tomotherapy; adaptive therapy;
D O I
10.1016/j.ijrobp.2005.11.012
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
Purpose: The gross tumor volume (GTV) for many lung cancer patients can decrease during the course of 14 radiation therapy. As the tumor reduces in size during treatment, the margin added around the GTV effectively becomes larger, which can result in the excessive irradiation of normal lung tissue. The specific goal of this study is to evaluate the feasibility of using image-guided adaptive radiation therapy to adjust the planning target volume weekly based on the previous week's CT image sets that were used for image-guided patient setup. Methods and Materials: Megavoltage computed tomography (MVCT) images of the GTV were acquired daily on a helical tomotherapy system. These images were used to position the patient and to measure reduction in GTV volume. A planning study was conducted to determine the amount of lung-sparing that could have been achieved if adaptive therapy had been used. Treatment plans were created in which the target volumes were reduced after tumor reduction was measured. Results: A total of 158 MVCT imaging sessions were performed on 7 lung patients. The GTV was reduced by 60-80% during the course of treatment. The tumor reduction in the first 60 days of treatment can be modeled using the second-order polynomial R=0.0002t(2)-0.0219t+1.0, where R is the percent reduction in GTV, and t is the number of elapsed days. Based on these treatment planning studies, the absolute volume of ipsilateral lung receiving 20 Gy can be reduced between 17% and 23% (21% mean) by adapting the treatment delivery. The benefits of adaptive therapy are the greatest for tumor volumes >= 25 cm(3) and are directly dependent on GTV reduction during treatment. Conclusions: Megavoltage CT-based image guidance can be used to position lung cancer patients daily. This has the potential to decrease margins associated with daily setup error. Furthermore, the adaptive therapy technique described in this article can decrease the volume of healthy lung tissue receiving above 20 Gy. However, further study is needed to determine whether adaptive therapy could result in the underdosing of microscopic extension. (C) 2006 Elsevier Inc.
引用
收藏
页码:1237 / 1244
页数:8
相关论文
共 33 条
[1]
Characterization of the output for helical delivery of intensity modulated slit beams [J].
Balog, JP ;
Mackie, TR ;
Reckwerdt, P ;
Glass, M ;
Angelos, L .
MEDICAL PHYSICS, 1999, 26 (01) :55-64
[2]
N-2 (CLINICAL) NON-SMALL-CELL CARCINOMA OF THE LUNG - PROSPECTIVE TRIALS OF RADIATION-THERAPY WITH TOTAL DOSES 60 GY BY THE RADIATION-THERAPY-ONCOLOGY-GROUP [J].
COX, JD ;
AZARNIA, N ;
BYHARDT, RW ;
SHIN, KH ;
EMAMI, B ;
PEREZ, CA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (01) :7-12
[3]
Optimization of beam weights in conformal radiotherapy planning of stage III non-small cell lung cancer: Effects on therapeutic ratio [J].
De Gersem, WRT ;
Derycke, S ;
De Wagter, C ;
De Neve, WCJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (01) :255-260
[4]
EMAMI B, 1997, PRINCIPLES PRACTICE, P1181
[5]
Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer [J].
Erridge, SC ;
Seppenwoolde, Y ;
Muller, SH ;
van Herk, M ;
De Jaeger, K ;
Belderbos, JSA ;
Boersma, LJ ;
Lebesque, JV .
RADIOTHERAPY AND ONCOLOGY, 2003, 66 (01) :75-85
[6]
The effect of patient-specific factors on radiation-induced regional lung injury [J].
Garipagaoglu, M ;
Munley, MT ;
Hollis, D ;
Poulson, JM ;
Bentel, GC ;
Sibley, G ;
Anscher, MS ;
Fan, M ;
Jaszczak, RJ ;
Coleman, RE ;
Marks, LB .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02) :331-338
[7]
The relationship between local dose and loss of function for irradiated lung [J].
Gopal, R ;
Tucker, SL ;
Komaki, R ;
Liao, ZX ;
Forster, KM ;
Stevens, C ;
Kelly, JF ;
Starkschall, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01) :106-113
[8]
Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC) [J].
Graham, MV ;
Purdy, JA ;
Emami, B ;
Harms, W ;
Bosch, W ;
Lockett, MA ;
Perez, CA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02) :323-329
[9]
RESULTS OF HIGH-DOSE THORACIC IRRADIATION INCORPORATING BEAMS EYE VIEW DISPLAY IN NONSMALL CELL LUNG-CANCER - A RETROSPECTIVE MULTIVARIATE-ANALYSIS [J].
HAZUKA, MB ;
TURRISI, AT ;
LUTZ, ST ;
MARTEL, MK ;
TENHAKEN, RK ;
STRAWDERMAN, M ;
BOREMA, PL ;
LICHTER, AS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (02) :273-284
[10]
Jaeger K. D., 2003, INT J RADIAT ONCOL, V55, P1331