Comparison of luminal enlargement by direct coronary stenting versus predilation coronary stenting by three-dimensional volumetric intravascular ultrasound analysis

被引:16
作者
Finet, G
Weissman, NJ
Mintz, GS
Satler, LF
Kent, KM
Castagna, MT
Ajani, AE
Pichard, AD
机构
[1] Washington Hosp Ctr, Inst Cardiovasc Res, Intravasc Ultrasound Imaging Lab, Washington, DC 20010 USA
[2] Washington Hosp Ctr, Inst Cardiovasc Res, Cardiac Catheterizat Lab, Washington, DC 20010 USA
关键词
D O I
10.1016/S0002-9149(01)02057-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study compared the mechanism of lumen enlargement between direct stenting versus predilation stenting using volumetric intravacular ultrasound methodology in 60 native coronary lesions treated with the same stent design and the same stent length. We showed that the mechanisms of lumen enlargement during stent implantation do not appear to be different in both groups, with similar plaque compression/embolization and a more even axial redistribution of the plaque with direct stenting than with predilation stenting.
引用
收藏
页码:1179 / +
页数:6
相关论文
共 16 条
[1]   Mechanism of lumen enlargement during intracoronary stent implantation - An intravascular ultrasound study [J].
Ahmed, JM ;
Mintz, GS ;
Weissman, NJ ;
Lansky, AJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM .
CIRCULATION, 2000, 102 (01) :7-10
[2]   Mechanisms of luminal enlargement and quantification of vessel wall trauma following balloon coronary angioplasty and directional atherectomy - A study using intracoronary ultrasound, angioscopy and angiography [J].
Baptista, J ;
Umans, VA ;
diMario, C ;
Escaned, J ;
deFeyter, P ;
Serruys, PW .
EUROPEAN HEART JOURNAL, 1995, 16 (11) :1603-1612
[3]   Clinical application and image interpretation in intracoronary ultrasound [J].
Di Mario, C ;
Gorge, G ;
Peters, R ;
Kearney, P ;
Pinto, F ;
Hausmann, D ;
von Birgelen, C ;
Colombo, A ;
Mudra, H ;
Roelandt, J ;
Erbel, R .
EUROPEAN HEART JOURNAL, 1998, 19 (02) :207-229
[4]  
Figulla HR, 1998, CATHETER CARDIO DIAG, V43, P245, DOI 10.1002/(SICI)1097-0304(199803)43:3<245::AID-CCD1>3.0.CO
[5]  
2-9
[6]   Artifacts in intravascular ultrasound imaging during coronary artery stent implantation [J].
Finet, G ;
Cachard, C ;
Delachartre, P ;
Maurincomme, E ;
Beaune, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (06) :793-802
[7]   Parameters that influence accuracy and precision of quantitative coronary arteriography [J].
Finet, G ;
Lienard, J .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1996, 12 (04) :271-287
[8]   Evaluation of an automatic intraluminal edge detection technique for intravascular ultrasound images [J].
Finet, G ;
Maurincomme, E ;
Reiber, JHC ;
Savalle, L ;
Magnin, I ;
Beaune, J .
JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1998, 62 (02) :115-121
[9]   In vivo validation of intravascular ultrasound length measurements using a motorized transducer pullback system [J].
Fuessl, RT ;
Mintz, GS ;
Pichard, AD ;
Kent, KM ;
Satler, LF ;
Popma, JJ ;
Leon, MB .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (12) :1115-&
[10]   MORPHOLOGICAL EFFECTS OF CORONARY BALLOON ANGIOPLASTY INVIVO ASSESSED BY INTRAVASCULAR ULTRASOUND IMAGING [J].
HONYE, J ;
MAHON, DJ ;
JAIN, A ;
WHITE, CJ ;
RAMEE, SR ;
WALLIS, JB ;
ALZARKA, A ;
TOBIS, JM .
CIRCULATION, 1992, 85 (03) :1012-1025