Artifacts in intravascular ultrasound imaging during coronary artery stent implantation

被引:15
作者
Finet, G
Cachard, C
Delachartre, P
Maurincomme, E
Beaune, J
机构
[1] Hospices Civils Lyon, Dept Hemodynam, Lyon, France
[2] Univ Lyon 1, F-69365 Lyon, France
[3] INSERM, CREATIS, CNRS, Res Unit 1216, F-69008 Lyon, France
关键词
ultrasound; intravascular ultrasound; stents; artifacts; angiography; image processing;
D O I
10.1016/S0301-5629(98)00041-6
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Intravascular ultrasound imaging is able to provide direct images of the stent meshwork. However, a paradoxical question remains unanswered: Why is it not possible to correct or prevent implantation defects by ultrasound-guided implantation? We postulate that these discrepancies are due to image artifacts, We performed an in vitro experiment allowing detection, physical characterization, and computerized simulations of the various aspects of these artifacts. The width of the echo of a strut is variable, dependent on its distance from the transducer, The stent strut echo orientation is variable, and depends on the position of the transducer inside the stent, The stent contour image depends on the position of the transducer, In conclusion, knowledge of these stent intravascular ultrasound image artifacts enabled us to discriminate accurately between artifacts and real stent implantation defects, and are indispensable for accurate qualitative and quantitative analyses of stents, (C) 1998 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:793 / 802
页数:10
相关论文
共 23 条
[1]  
Cavaye D M, 1991, Ann Vasc Surg, V5, P241, DOI 10.1007/BF02329380
[2]   ARTIFACTS IN INTRAVASCULAR ULTRASOUND IMAGING - ANALYSES AND IMPLICATIONS [J].
FINET, G ;
MAURINCOMME, E ;
TABIB, A ;
CROWLEY, RJ ;
MAGNIN, I ;
RORIZ, R ;
BEAUNE, J ;
AMIEL, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (07) :533-547
[3]   3-LAYER APPEARANCE OF THE ARTERIAL-WALL IN INTRAVASCULAR ULTRASOUND IMAGING [J].
FINET, G ;
MAURINCOMME, E ;
DOUEK, P ;
TABIB, A ;
AMIEL, M ;
BEAUNE, J .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1994, 11 (04) :343-363
[4]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[5]   INTRAVASCULAR ULTRASOUND AFTER LOW AND HIGH INFLATION PRESSURE CORONARY-ARTERY STENT IMPLANTATION [J].
GORGE, G ;
HAUDE, M ;
VOEGELE, E ;
GERBER, T ;
RUPPRECHT, HJ ;
MEYER, J ;
ERBEL, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (03) :725-730
[6]  
GRONNINGSAETER A, 1995, J VASC INVEST, V1, P140
[7]   CORONARY STENT IMPLANTATION IN ACUTE VESSEL CLOSURE 48 HOURS AFTER AN UNSATISFACTORY CORONARY ANGIOPLASTY [J].
HAUDE, M ;
ERBEL, R ;
STRAUB, U ;
DIETZ, U ;
SCHATZ, R ;
MEYER, J .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1990, 21 (04) :263-265
[8]   WHAT MIGHT ECHOGRAPHY LEARN FROM IMAGE SCIENCE [J].
HILL, CR ;
BAMBER, JC ;
CRAWFORD, DC ;
LOWE, HJ ;
WEBB, S .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (06) :559-575
[9]   A study of the quantitative and qualitative impact of catheter shaft angulation in a mechanical intravascular ultrasound system [J].
Kearney, PP ;
Ramo, MP ;
Spencer, T ;
Shaw, TRD ;
Starkey, IR ;
McDicken, N ;
Sutherland, GR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (01) :87-93
[10]  
KROON GM, 1991, ULTRASOUND MED BIOL, V17, P121