Alternative approaches for the detection of various phospholipid classes by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

被引:99
作者
Estrada, R [1 ]
Yappert, MC [1 ]
机构
[1] Univ Louisville, Dept Chem, Louisville, KY 40292 USA
来源
JOURNAL OF MASS SPECTROMETRY | 2004年 / 39卷 / 04期
关键词
phospholipids; matrix-assisted laser desorption/ionization time-of-flight mass spectrometry; p-nitroaniline; sphingomyelins; phosphatidylcholines; phosphatidylethanolamines;
D O I
10.1002/jms.603
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The detection of phospholipids (PLs) by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was demonstrated nearly a decade ago. However, its use as a conventional tool for PL analysis has been hindered by ambiguities in peak assignments caused by spectral overlaps and difficulties in the detection of some PL classes when analytes with positively charged head groups, such as sphingomyelins (SMs) and phosphatidylcholines (PCs) are present. In this work, either a strong cation-exchange resin or CsCl crystals were added directly to the PL samples to reduce spectral complexity and enhance sensitivity. The quantitative exchange resulted in virtually only protonated or Cs+ adducts. To alleviate difficulties in the detection and identification of PL classes with ionization efficiencies lower than those of SMs and PCs, improvements in the sensitivity of negative-ion mass spectra were sought. For this purpose, several neutral and basic matrices were tried. Among them, p-nitroaniline (PNA) proved to be an advantageous alternative to the use of 2,5-dihydroxybenzoic acid (DHB), the most commonly used matrix in PL analysis. Because of its lower acidity, PNA increased the relative amount of deprotonated species and improved the sensitivity of negative-ion mass spectra. It was possible to confirm peak assignments for PL classes that normally give weak signals when DHB is used. Noteworthy is the detection (in both positive and negative modes) and conclusive identification of species in natural mixtures of phosphatidylethanolamines (PEs) and PE plasmalogens (PEps). PNA allowed the identification of PEs and PEps even in mixtures containing SMs and PCs. Although some cations related to PCs and PEs overlapped in positive-ion spectra, these interferences were eliminated in the negative mode as only the deprotonated forms of PEs and PEps were detectable and those of SMs and PCs were absent owing to their neutrality. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:412 / 422
页数:11
相关论文
共 31 条
[21]   Negative-ion matrix-assisted laser desorption and ionization time-of-flight mass spectra of complex phospholipid mixtures in the presence of phosphatidylcholine:: a cautionary note on peak assignment [J].
Schiller, J ;
Süss, R ;
Petkovic, M ;
Zschörnig, O ;
Arnold, K .
ANALYTICAL BIOCHEMISTRY, 2002, 309 (02) :311-314
[22]   CsCl as an auxiliary reagent for the analysis of phosphatidylcholine mixtures by matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) [J].
Schiller, J ;
Sübb, R ;
Petkovic, M ;
Hilbert, N ;
Müller, M ;
Szchörnig, O ;
Arnhold, J ;
Arnold, K .
CHEMISTRY AND PHYSICS OF LIPIDS, 2001, 113 (1-2) :123-131
[23]   Lipid analysis of bronchoalveolar lavage fluid (BAL) by MALDI-TOF mass spectrometry and 31P NMR spectroscopy [J].
Schiller, J ;
Hammerschmidt, S ;
Wirtz, H ;
Arnhold, J ;
Arnold, K .
CHEMISTRY AND PHYSICS OF LIPIDS, 2001, 112 (01) :67-79
[24]  
Schiller J, 2001, J LIPID RES, V42, P1501
[25]  
Schiller J, 2000, ENCY ANAL CHEM, P559
[26]   Matrix-assisted laser desorption mass spectrometry [J].
Stump, MJ ;
Fleming, RC ;
Gong, WH ;
Jaber, AJ ;
Jones, JJ ;
Surber, CW ;
Wilkins, CL .
APPLIED SPECTROSCOPY REVIEWS, 2002, 37 (03) :275-303
[27]   Application of matrix assisted laser desorption ionization time-of-flight mass spectrometry with delayed ion extraction to ganglioside analyses [J].
Sugiyama, E ;
Hara, A ;
Uemura, K ;
Taketomi, T .
GLYCOBIOLOGY, 1997, 7 (05) :719-724
[28]   Characterisation of bacteria by matrix-assisted laser desorption/ionisation and electrospray mass spectrometry [J].
van Baar, BLM .
FEMS MICROBIOLOGY REVIEWS, 2000, 24 (02) :193-219
[29]   Matrix-assisted laser desorption/ionization Fourier transform mass spectrometric analysis of oxygenated triglycerides and phosphatidylcholines in egg tempera paint dosimeters used for environmental monitoring of museum display conditions [J].
van den Brink, OF ;
Boon, JJ ;
O'Connor, PB ;
Duursma, MC ;
Heeren, RMA .
JOURNAL OF MASS SPECTROMETRY, 2001, 36 (05) :479-492
[30]   Glycero-versus sphingo-phospholipids: correlations with human and non-human mammalian lens growth [J].
Yappert, MC ;
Rujoi, M ;
Borchman, D ;
Vorobyov, I ;
Estrada, R .
EXPERIMENTAL EYE RESEARCH, 2003, 76 (06) :725-734