Self-calibrating parallel imaging with automatic coil sensitivity extraction

被引:156
作者
McKenzie, CA
Yeh, EN
Ohliger, MA
Price, MD
Sodickson, DK
机构
[1] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Harvard Mit Div Hlth Sci & Technol, Boston, MA USA
关键词
parallel MRI; sensitivity calibration; coil arrays; SMASH; SENSE;
D O I
10.1002/mrm.10087
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Calibration of the spatial sensitivity functions of coil arrays is a crucial element in parallel magnetic resonance imaging (PMRI). The most common approach has been to measure coil sensitivities directly using one or more low-resolution images acquired before or after accelerated data acquisition. However, since it is difficult to ensure that the patient and coil array will be in exactly the same positions during both calibration scans and accelerated imaging, this approach can introduce sensitivity miscalibration errors into PMRI reconstructions. This work shows that it is possible to extract sensitivity calibration images directly from a fully sampled central region of a variable-density k-space acquisition. These images have all the features of traditional PMRI sensitivity calibrations and therefore may be used for any PMRI reconstruction technique without modification. Because these calibration data are acquired simultaneously with the data to be reconstructed, errors due to sensitivity miscalibration are eliminated. In vivo implementations of self-calibrating parallel imaging using a flexible coil array are demonstrated in abdominal imaging and in real-time cardiac imaging studies. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:529 / 538
页数:10
相关论文
共 23 条
[1]  
Ben-Israel A., 1977, GEN INVERSES THEORY
[2]  
BUNDY JM, 1999, P 7 ANN M ISMRM PHIL, P386
[3]  
GRISWOLD MA, 2001, P 9 ANN M ISMRM GLAS, P8
[4]  
HEID O, 1997, P 5 ANN M ISMRM VANC, P320
[5]   VD-AUTO-SMASH imaging [J].
Heidemann, RM ;
Griswold, MA ;
Haase, A ;
Jakob, PM .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (06) :1066-1074
[6]  
Jakob PM, 1998, MAGN RESON MATER PHY, V7, P42
[7]  
Kyriakos WE, 2000, MAGNET RESON MED, V44, P301, DOI 10.1002/1522-2594(200008)44:2<301::AID-MRM18>3.0.CO
[8]  
2-D
[9]   Improved spatial harmonic selection for SMASH image reconstructions [J].
McKenzie, CA ;
Yeh, EN ;
Sodickson, DK .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) :831-836
[10]   Coil-by-coil image reconstruction with SMASH [J].
McKenzie, CA ;
Ohliger, MA ;
Yeh, EN ;
Price, MD ;
Sodickson, DK .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :619-623