Optical coherence tomography: Real-time imaging of bronchial airways microstructure and detection of inflammatory/neoplastic morphologic changes

被引:69
作者
Whiteman, SC [1 ]
Yang, Y
van Pittius, DG
Stephens, M
Parmer, J
Spiteri, MA
机构
[1] Keele Univ, Postgrad Med Sch, Inst Sci & Technol Med, Stoke On Trent ST4 7QB, Staffs, England
[2] Univ Hosp N Staffordshire, Directorate Resp Med, Stoke On Trent, Staffs, England
[3] Univ Hosp N Staffordshire, Dept Histopathol, Stoke On Trent, Staffs, England
[4] Univ Hosp N Staffordshire, Dept Cardiothorac Surg, Stoke On Trent, Staffs, England
关键词
D O I
10.1158/1078-0432.CCR-05-0245
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Current diagnostic imaging modalities for human bronchial airways do not possess sufficient resolution and tissue penetration depth to detect early morphologic changes and to differentiate in real-time neoplastic pathology from nonspecific aberrations. Optical coherence tomography (OCT) possesses the requisite high spatial resolution for reproducible delineation of endobronchial wall profiling. Experimental Design: To establish whether OCT could differentiate between the composite microstructural layers of the human airways and simultaneously determine in situ morphologic changes, using a bench-top OCT system, we obtained cross-sectional images of bronchi from 15 patients undergoing lung resections for cancer. All scanned sections underwent subsequent detailed histologic analysis, allowing direct comparisons to be made. Results: OCT imaging enables characterization of the multilayered microstructural anatomy of the airways, with a maximum penetration depth up to 2 to 3 mm and 10-mu m spatial resolution. The epithelium, subepithelial components, and cartilage are individually defined. The acquired OCT images closely match histologically defined patterns in terms of structural profiles. Furthermore, OCT identifies in situ morphologic changes associated with inflammatory infiltrates, squamous metaplasia, and tumor presence. Conclusions: Our results confirm that OCT is a highly feasible optical too] for real-time near-histologic imaging of endobronchial pathology, with potential for lung cancer surveillance applications in diagnosis and treatment.
引用
收藏
页码:813 / 818
页数:6
相关论文
共 28 条
  • [1] BECKER HD, 2002, LUNG CANCER, V29, P144
  • [2] Estimated radiation risks potentially associated with full-body CT screening
    Brenner, DJ
    Elliston, CD
    [J]. RADIOLOGY, 2004, 232 (03) : 735 - 738
  • [3] Drexler W, 2001, J RHEUMATOL, V28, P1311
  • [4] High resolution in vivo intra-arterial imaging with optical coherence tomography
    Fujimoto, JG
    Boppart, SA
    Tearney, GJ
    Bouma, BE
    Pitris, C
    Brezinski, ME
    [J]. HEART, 1999, 82 (02) : 128 - 133
  • [5] In vivo optical coherence tomography imaging of human skin: norm and pathology
    Gladkova, ND
    Petrova, GA
    Nikulin, NK
    Radenska-Lopovok, SG
    Snopova, LB
    Chumakov, YP
    Nasonova, VA
    Gelikonov, VM
    Gelikonov, GV
    Kuranov, RV
    Sergeev, AM
    Feldchtein, FI
    [J]. SKIN RESEARCH AND TECHNOLOGY, 2000, 6 (01) : 6 - 16
  • [6] Two-dimensonal and 3-dimensional optical coherence tomographic imaging of the airway, lung, and pleura
    Hanna, N
    Saltzman, D
    Mukai, D
    Chen, Z
    Sasse, S
    Milliken, J
    Guo, S
    Jung, W
    Colt, H
    Brenner, M
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 129 (03) : 615 - 622
  • [7] OPTICAL COHERENCE TOMOGRAPHY OF THE HUMAN RETINA
    HEE, MR
    IZATT, JA
    SWANSON, EA
    HUANG, D
    SCHUMAN, JS
    LIN, CP
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (03) : 325 - 332
  • [8] Fluorescence versus white-light bronchoscopy for detection of preneoplastic lesions: a randomized study
    Hirsch, FR
    Prindiville, SA
    Miller, Y
    Franklin, WA
    Dempsey, EC
    Murphy, JR
    Bunn, PA
    Kennedy, TC
    [J]. JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2001, 93 (18): : 1385 - 1391
  • [9] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181
  • [10] Peripheral lung cancer: Screening and detection with low-dose spiral CT versus radiography
    Kaneko, M
    Eguchi, K
    Ohmatsu, H
    Kakinuma, R
    Naruke, T
    Suemasu, K
    Moriyama, N
    [J]. RADIOLOGY, 1996, 201 (03) : 798 - 802