Raman spectroscopy as a process analytical technology (PAT) tool for the in-line monitoring and understanding of a powder blending process

被引:125
作者
De Beer, T. R. M. [1 ]
Bodson, C. [2 ]
Dejaegher, B. [3 ]
Walczak, B. [4 ]
Vercruysse, P. [1 ]
Burggraeve, A. [1 ]
Lemos, A. [1 ]
Delattre, L. [2 ]
Heyden, Y. Vander [3 ]
Remon, J. P. [5 ]
Vervaete, C. [5 ]
Baeyens, W. R. G. [1 ]
机构
[1] Univ Ghent, Lab Pharmaceut Chem & Drug Anal, Dept Pharmaceut Anal, B-9000 Ghent, Belgium
[2] Univ Liege, Dept Pharm, Pharmaceut Technol Lab, B-4000 Liege, Belgium
[3] Vrije Univ Brussel, Inst Pharmaceut, Dept Analyt Chem & Pharmaceut Technol, B-1090 Brussels, Belgium
[4] Univ Silesia, Dept Chemometr, PL-40006 Katowice, Poland
[5] Univ Ghent, Pharmaceut Technol Lab, Dept Pharmaceut, B-9000 Ghent, Belgium
关键词
Raman spectroscopy; NIR spectroscopy; PAT; Blending; Experimental design; In-line monitoring; Process understanding; MD; Orthogonal distance; SIMCA;
D O I
10.1016/j.jpba.2008.07.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of this study is to propose a strategy to implement a PAT system in the blending step of pharmaceutical production processes. It was examined whether Raman spectroscopy can be used as PAT tool for the in-line and real-time endpoint monitoring and understanding of a powder blending process. A screening design was used to identify and understand the significant effects of two process variables (blending speed and loading of the blender) and of a formulation variable (concentration of active pharmaceutical ingredient (API): diltiazem hydrochloride) upon the required blending time (response variable). Interactions between the variables were investigated as well. A Soft Independent Modelling of Class Analogy (SIMCA) model was developed to determine the homogeneity of the blends in-line and real-time using Raman spectroscopy in combination with a fiber optical immersion probe. One blending experiment was monitored using Raman and NIR spectroscopy simultaneously. This was done to verify whether two independent monitoring tools can confirm each other's endpoint conclusions. The analysis of the experimental design results showed that the measured endpoints were excessively rounded due to the large measurement intervals relative to the first blending times. This resulted in effects and critical effects which cannot be interpreted properly. To be able to study the effects properly, the ratio between the blending times and the measurement intervals should be sufficiently high. In this study, it anyway was demonstrated that Raman spectroscopy is a suitable PAT tool for the endpoint control of a powder blending process. Raman spectroscopy not only allowed in-line and real-time monitoring of the blend homogeneity, but also helped to understand the process better in combination with experimental design. Furthermore, the correctness of the Raman endpoint conclusions was demonstrated for one process by using a second independent endpoint monitoring tool (NIR spectroscopy). Hence, the use of two independent techniques for the control of one response variable not only means a mutual confirmation of both methods, but also provides a higher certainty in the determined endpoint. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:772 / 779
页数:8
相关论文
共 48 条
  • [1] AFNAN AM, 2004, J PAT, V1, P8
  • [2] [Anonymous], 2003, Data analysis for the laboratory and chemical plant
  • [3] [Anonymous], CHEMOM INTELL LAB SY
  • [4] Bakeev KA, 2005, PROCESS ANALYTICAL TECHNOLOGY: SPECTROSCOPIC TOOLS AND IMPLEMENTATION STRATEGIES FOR THE CHEMICAL AND PHARMACEUTICAL INDUSTRIES, P424, DOI 10.1002/9780470988459.ch12
  • [5] Balboni M. L., 2003, Pharm. Technol., V27, P54
  • [6] Unit dose sampling: A tale of two thieves
    Berman, J
    Schoeneman, A
    Shelton, JT
    [J]. DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1996, 22 (11) : 1121 - 1132
  • [7] BLEND UNIFORMITY AND UNIT DOSE SAMPLING
    BERMAN, J
    PLANCHARD, JA
    [J]. DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1995, 21 (11) : 1257 - 1283
  • [8] Quantitative in-line monitoring of powder blending by near infrared reflection spectroscopy
    Berntsson, O
    Danielsson, LG
    Lagerholm, B
    Folestad, S
    [J]. POWDER TECHNOLOGY, 2002, 123 (2-3) : 185 - 193
  • [9] Content uniformity and tablet hardness testing of intact pharmaceutical tablets by near infrared spectroscopy -: A contribution to process analytical technologies
    Blanco, M
    Alcalá, M
    [J]. ANALYTICA CHIMICA ACTA, 2006, 557 (1-2) : 353 - 359
  • [10] Monitoring powder blending in pharmaceutical processes by use of near infrared spectroscopy
    Blanco, M
    Bañó, RG
    Bertran, E
    [J]. TALANTA, 2002, 56 (01) : 203 - 212