Quantitative in-line monitoring of powder blending by near infrared reflection spectroscopy

被引:132
作者
Berntsson, O
Danielsson, LG
Lagerholm, B
Folestad, S
机构
[1] Royal Inst Technol, Kungl Tekniska Hogskolan, Div Analyt Chem, Dept Chem, SE-10044 Stockholm, Sweden
[2] AstraZeneca R&D, Pharmaceut & Analyt R&D, SE-43183 Molndal, Sweden
关键词
powder mixing; near infrared; monitoring; homogeneity; nauta mixer;
D O I
10.1016/S0032-5910(01)00456-9
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A method for quantitative in-situ measurements of the chemical content of powder mixtures is presented. By means of near infrared spectroscopy (NIR) and a fiber-optic diffuse reflection probe inserted into the powder in the blender, determinations of the powder mixture content can be made during processing. A simplified methodology for multivariate calibration is used to determine the powder content from the NIR spectra. With this methodology, calibration samples are prepared and analyzed off-line. The presented method can be used to monitor the content and the homogeneity of powder mixtures in real time and thus to assess the performance of powder handling operations, such as powder mixing, during development, scale-up and production. In this paper, an Fourier transform (FF)-NIR spectrometer was used to monitor the mixing of a segregating powder mixture, consisting of a coarse (d > 300 mum) and a fine powder (d < 200 mum), in a convective mixer (Nauta mixer). Both a small laboratory-scale and a large production-scale mixer were used. It is demonstrated that by high-speed sampling, both the average content and the distribution of the mixture content can be assessed during processing. The experimental content vs. process time trajectories are in good agreement with a theoretical simulation model for blending in Nauta mixers. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:185 / 193
页数:9
相关论文
共 74 条
[1]   POWDER COATING IN A ROTARY MIXER WITH ROCKING MOTION [J].
ALONSO, M ;
SATOH, M ;
MIYANAMI, K .
POWDER TECHNOLOGY, 1988, 56 (02) :135-141
[2]   Quantitative analysis of film coating in a fluidized bed process by in line NIR spectrometry and multivariate batch calibration [J].
Andersson, M ;
Folestad, S ;
Gottfries, J ;
Johansson, MO ;
Josefson, M ;
Wahlund, KG .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :2099-2108
[3]  
ANDERSSON M, 2001, UNPUB ANAL CHIM ACTA
[4]  
[Anonymous], 1993, J NEAR INFRARED SPEC, DOI DOI 10.1255/jnirs.25
[5]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[6]  
[Anonymous], 1998, MULTIVARIATE ANAL PR
[7]   USE OF A LIGHT PROBE FOR ASSESSING HOMOGENEITY OF POWDER MIXTURES [J].
ASHTON, MD ;
SCHOFIEL.C ;
VALENTIN, FH .
CHEMICAL ENGINEERING SCIENCE, 1966, 21 (10) :843-&
[8]   STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA [J].
BARNES, RJ ;
DHANOA, MS ;
LISTER, SJ .
APPLIED SPECTROSCOPY, 1989, 43 (05) :772-777
[9]   Characterization of diffuse reflectance fiber probe sampling on moving solids using a Fourier transform near-infrared spectrometer [J].
Berntsson, O ;
Danielsson, LG ;
Folestad, S .
ANALYTICA CHIMICA ACTA, 2001, 431 (01) :125-131
[10]   Quantitative determination of content in binary powder mixtures using diffuse reflectance near infrared spectrometry and multivariate analysis [J].
Berntsson, O ;
Danielsson, LG ;
Johansson, MO ;
Folestad, S .
ANALYTICA CHIMICA ACTA, 2000, 419 (01) :45-54