MITIGATING AMMONIA AND PM GENERATION OF CAGE-FREE HENHOUSE LITTER WITH SOLID ADDITIVE AND LIQUID SPRAY

被引:18
作者
Chai, L. [1 ]
Xin, H. [1 ,2 ]
Zhao, Y. [3 ]
Wang, T. [4 ]
Soupir, M. [1 ]
Liu, K. [1 ]
机构
[1] Iowa State Univ, Dept Agr & Biosyst Engn, Ames, IA USA
[2] Iowa State Univ, Egg Ind Ctr, Ames, IA USA
[3] Mississippi State Univ, Dept Agr & Biol Engn, Mississippi State, MS 39762 USA
[4] Iowa State Univ, Dept Food Sci & Human Nutr, Ames, IA USA
关键词
Air quality; Alternative hen housing; Animal and worker health; Litter treatment; ACIDIC ELECTROLYZED WATER; EGG-PRODUCTION SYSTEMS; LAYING HEN HOUSES; PARTICULATE-MATTER; ENVIRONMENTAL ASSESSMENT; CHEMICAL AMENDMENTS; AIRBORNE BACTERIA; GREENHOUSE-GAS; REDUCTION; EMISSIONS;
D O I
10.13031/trans.12481
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
A number of chain restaurants, retailers, and grocers in the U.S. have pledged to source only cage-free (CF) eggs in the foreseeable future (e.g., by 2025) due to marketing reasons or concerns over animal welfare. However, CF housing has some inherent challenges, and a predominant one is poor air quality, i.e., ammonia gas (NH3) and particulate matter (PM), and increased emissions. Spraying a liquid agent such as electrolyzed water (EW) can effectively suppress PM generation of CF henhouse litter. However, liquid spray can enhance NH3 generation because it increases the litter moisture content (LMC). Application of acidic liquid to the litter would help control NH3 while suppressing PM, but concerns arise about the potential corrosive effect of acidic liquid on housing equipment. To overcome this dilemma, this study evaluated the effect of applying PLT, a commercial poultry litter additive (LA), on NH3 emissions of CF hen litter while spraying it with neutral EW (NEW) at a rate of 25 mL kg(-1) dry litter d(-1). The PLT application rates were 0.3, 0.6, and 0.9 kg m(-2), denoted as Low-LA, Med-LA, and High-LA, respectively. CF litter was placed inside dynamic emission chambers and automatically stirred to mimic hen scratching. PLT was topically applied onto the litter on day 1; NEW was sprayed daily for 11 d, followed by a 3 d non-spray period (i.e., 14 d per trial); and each regimen was replicated four times. The ammonia emission rate (ER) of the control (no LA), Low-LA, Med-LA, and High-LA regimens (mean. SE) was, respectively, 0.76 +/- 0.05, 0.55 +/- 0.06, 0.37 +/- 0.04, and 0.16 +/- 0.02 g kg(-1) dry litter d(-1), i.e., 28% to 79% reduction by the treatments. The NH3 reduction efficiency was linearly proportional to the PLT application rate, with higher application rate resulting in lower litter pH (p < 0.05). At the end of each trial (d14), the Med-LA and High- LA regimens still showed relatively low NH3 emissions, suggesting the need for a longer measurement period in future studies. The NEW spray increased LMC by up to 60% after 11 once-a-day sprays, which reduced PM2.5, PM10, and TSP levels from 3.83, 6.39, and 7 mg m(-3) to 0.07, 0.14, and 0.15 mg m(-3), respectively. After a 3 d spray suspension, the PM levels rebounded to 0.72, 1.02, and 1.12 mg m(-3) for PM2.5, PM10, and TSP, respectively, due to decreased LMC. Field verification of the mitigation efficacy and an economic assessment of the method are warranted.
引用
收藏
页码:287 / 294
页数:8
相关论文
共 31 条
[1]   Air disinfection in laying hen houses: Effect on airborne microorganisms with focus on Mycoplasma gallisepticum [J].
Adell, Elisa ;
Calvet, Salvador ;
Perez-Bonilla, Adriano ;
Jimenez-Belenguer, Ana ;
Garcia, Julio ;
Herrera, Jorge ;
Cambra-Lopez, Maria .
BIOSYSTEMS ENGINEERING, 2015, 129 :315-323
[2]   Litter use by laying hens in a commercial aviary: dust bathing and piling [J].
Campbell, D. L. M. ;
Makagon, M. M. ;
Swanson, J. C. ;
Siegford, J. M. .
POULTRY SCIENCE, 2016, 95 (01) :164-175
[3]   REDUCTION OF PARTICULATE MATTER AND AMMONIA BY SPRAYING ACIDIC ELECTROLYZED WATER ONTO LITTER OF AVIARY HEN HOUSES: A LAB-SCALE STUDY [J].
Chai, L. ;
Zhao, Y. ;
Xin, H. ;
Wang, T. ;
Atilgan, A. ;
Soupir, M. ;
Liu, K. .
TRANSACTIONS OF THE ASABE, 2017, 60 (02) :497-506
[4]  
Fairchild B. D., 2006, 064187 ASABE
[5]  
Hayes MD, 2013, T ASABE, V56, P1921
[6]  
Knueven C. J., 1999, U.S. Patent, Patent No. [5,958,491, 5958491]
[7]   Reduction of Ammonia Emissions from Stored Laying Hen Manure Through Topical Application of Zeolite, Al+ Clear, Ferix-3, or Poultry Litter Treatment [J].
Li, H. ;
Xin, H. ;
Liang, Y. ;
Burns, R. T. .
JOURNAL OF APPLIED POULTRY RESEARCH, 2008, 17 (04) :421-431
[8]   Assessment of frequent litter amendment application on ammonia emission from broilers operations [J].
Li, Hong ;
Lin, Chongyang ;
Collier, Stephen ;
Brown, William ;
White-Hansen, Susan .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2013, 63 (04) :442-452
[9]  
Liang Y, 2005, T ASAE, V48, P1927, DOI 10.13031/2013.20002
[10]  
Liang Y., 2005, 20054160 ASAE