Reliability of gas exchange measurements from two different spiroergometry systems

被引:95
作者
Meyer, T [1 ]
Georg, T
Becker, C
Kindermann, W
机构
[1] Univ Saarland, Inst Sports & Prevent Med, D-66041 Saarbrucken, Germany
[2] Univ Saarland, Inst Med Biometr Epidemiol & Med Informat, D-6650 Homburg, Germany
关键词
reproducibility; reliability coefficient; gas exchange; Bland-Altman;
D O I
10.1055/s-2001-18523
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Reliability of two different spiroergometric systems was investigated by comparing gas exchange measurements from two consecutive identical bicycle ergometer ramp exercise tests which were conducted after an initial habituation trial. Twenty-three healthy subjects (age: 25 +/- 5 years; weight: 71 +/- 10 kg; peak oxygen uptake: 55 +/- 9 ml x min(-1) x kg(-1)) took part in the study. One apparatus was a portable mixing chamber system (MetaMax I, Cortex, Leipzig, Germany), the other one a stationary spiroergometric device measuring in the breath-by-breath mode (MetaLyzer 3B, Cortex). There were no relevant systematic changes in gas exchange measurements and heart rate from test 1 to test 2. Intra-class reliability coefficients were 0.984 (oxygen uptake = VO2), 0.977 (carbon dioxide Output = VCO2), and 0.973 (minute ventilation = V-E) for the MetaMax I, and 0.969 (VO2), 0.964 (VCO2), and 0.953 (V-E) for the MetaLyzer 3B. Bland-Altman plots revealed a slightly smaller variability of MetaLyzer 3B measurements compared to those of MetaMax I. It is concluded that the spiroergometric devices MetaMax I and MetaLyzer 3B represent reliable instruments for exercise testing in sports medical routine and research. This is important to decide if longitudinal changes in gas exchange measurements represent clinically meaningful differences in performance or merely inconsistencies of the measuring tool.
引用
收藏
页码:593 / 597
页数:5
相关论文
共 10 条
[1]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[2]   RELIABILITY AND WITHIN-SUBJECT VARIABILITY OF VE, VO2, HEART-RATE AND BLOOD-PRESSURE DURING SUBMAXIMUM CYCLE ERGOMETRY [J].
BECQUE, MD ;
KATCH, V ;
MARKS, C ;
DYER, R .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1993, 14 (04) :220-223
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   OPTIMIZING THE EXERCISE PROTOCOL FOR CARDIOPULMONARY ASSESSMENT [J].
BUCHFUHRER, MJ ;
HANSEN, JE ;
ROBINSON, TE ;
SUE, DY ;
WASSERMAN, K ;
WHIPP, BJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 55 (05) :1558-1564
[5]   Reliability of submaximal exercise tests in patients with COPD [J].
Covey, MK ;
Larson, JL ;
Wirtz, S .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1999, 31 (09) :1257-1264
[6]   BIOLOGICAL VARIABILITY IN MAXIMUM AEROBIC POWER [J].
KATCH, VL ;
SADY, SS ;
FREEDSON, P .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1982, 14 (01) :21-25
[7]   RELIABILITY OF MEASUREMENT OF OXYGEN-UPTAKE BY A PORTABLE TELEMETRIC SYSTEM [J].
KAWAKAMI, Y ;
NOZAKI, D ;
MATSUO, A ;
FUKUNAGA, T .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1992, 65 (05) :409-414
[8]   VALIDITY AND RELIABILITY OF THE COSMED K2 TO MEASURE OXYGEN-UPTAKE [J].
LOTHIAN, F ;
FARRALLY, MR ;
MAHONEY, C .
CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 1993, 18 (02) :197-206
[9]   VALIDITY AND RELIABILITY OF THE COSMED K2 INSTRUMENT [J].
LUCIA, A ;
FLECK, SJ ;
GOTSHALL, RW ;
KEARNEY, JT .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1993, 14 (07) :380-386
[10]  
Wasserman K., 1999, PRINCIPLES EXERCISE