Influence of helical CT parameters on spatial resolution in CT angiography performed with a subsecond scanner

被引:18
作者
Luboldt, W [1 ]
Weber, R [1 ]
Seemann, M [1 ]
Desantis, M [1 ]
Reiser, M [1 ]
机构
[1] Univ Hosp Grosshadern, Inst Diagnost Radiol, Munich, Germany
关键词
helical CT; CT angiography; partial volume; noise; spatial resolution;
D O I
10.1097/00004424-199906000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. In helical CT, the beam collimation, table feed (TF) per tube rotation, voltage, current, reconstruction increment, kernel, linear interpolation algorithm (LIA), and contrast are variable parameters. The purpose of this study was to determine which of these parameters are most important to minimize partial volume effects for improving spatial resolution in CT angiography. METHODS. Phantom vessel stenoses of different lengths (2, 8 mm) and diameters (0.5, 1, 2, 3, 4 mm) were scanned with helical CT using a constant tube rotation time of 0.75 sec and 42 selected combinations of the above-mentioned parameters. Orthogonal targeted maximum intensity projections of the stenoses were ordered according to the increase in blurring and noise in a consensus reading by two radiologists blinded to the parameters used. RESULTS. Three millimeters of collimation and TF in conjunction with a 180 degrees LIA and >250 Hounsfield unit contrast density was considered the optimal parameter combination and enabled a continuous visualization of the stenoses down to 0.5 mm in diameter. A collimation of 1 or 2 mm and 5 mm was considered inferior to a collimation of 3 mm because of, respectively, noise and blurring. With 3 mm collimation, significant blurring occurred when a pitch larger than 1.5 was used. A 3 mm collimation with a pitch of 2 (6 mm TF) was found to be superior to a collimation of 5 mm in conjunction with a pitch of 1 (5 mm TF). With 5 mm collimation, the short stenoses could be visualized only when using a 180 degrees LIA and a TF per tube rotation smaller than 7 mm. Eight and 10 mm collimations failed to depict the short stenoses. CONCLUSIONS. Collimation had the most influence on image quality in CT angiography, followed by LIA, pitch, and contrast density. Decreasing the reconstruction increment to less than one third of the TF or increasing the voltage or current beyond standard values did not improve the delineation of the stenoses. For screening examinations, the authors recommend the use of 3 mm collimation, 180 degrees LIA, and a pitch of 2.
引用
收藏
页码:421 / 426
页数:6
相关论文
共 20 条
[1]   Experience with computed tomographic angiography for the detection of intracranial aneurysms in the setting of acute subarachnoid hemorrhage [J].
Wecht, DA ;
Awad, IA .
NEUROSURGERY, 1997, 41 (03) :528-528
[2]   Detection of colonic polyps in a phantom model: Implications for virtual colonoscopy data acquisition [J].
Beaulieu, CF ;
Napel, S ;
Daniel, BL ;
Ch'en, IY ;
Rubin, GD ;
Johnstone, IM ;
Jeffrey, RB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (04) :656-663
[3]   SPIRAL CT ANGIOGRAPHY - AN ALTERNATIVE TO CONVENTIONAL ANGIOGRAPHY [J].
BLUEMKE, DA ;
CHAMBERS, TP .
RADIOLOGY, 1995, 195 (02) :317-319
[4]   Spiral CT angiography of the abdomen and pelvis: Interventional applications [J].
Brink, JA .
ABDOMINAL IMAGING, 1997, 22 (04) :365-372
[5]   TECHNICAL OPTIMIZATION OF SPIRAL CT FOR DEPICTION OF RENAL-ARTERY STENOSIS - IN-VITRO ANALYSIS [J].
BRINK, JA ;
LIM, JT ;
WANG, G ;
HEIKEN, JP ;
DEYOE, LA ;
VANNIER, MW .
RADIOLOGY, 1995, 194 (01) :157-163
[6]   CT ANGIOGRAPHY OF THE COMMON CAROTID-ARTERY BIFURCATION - COMPARISON BETWEEN 2 TECHNIQUES AND CONVENTIONAL ANGIOGRAPHY [J].
CASTILLO, M ;
WILSON, JD .
NEURORADIOLOGY, 1994, 36 (08) :602-604
[7]   Helical CT angiography in the preoperative evaluation of carotid artery stenosis - Discussion [J].
Reilly, LM ;
Cinat, M ;
Strandness, E ;
Moneta, G .
JOURNAL OF VASCULAR SURGERY, 1998, 28 (02) :297-300
[8]  
Farres MT, 1996, CARDIOVASC INTER RAD, V19, P101
[9]   Spiral CT angiography: Study of stenoses and calcification at the origin of the vertebral artery [J].
Farres, MT ;
Grabenwoger, F ;
Magometschnig, H ;
Trattnig, S ;
Heimberger, K ;
Lammer, J .
NEURORADIOLOGY, 1996, 38 (08) :738-743
[10]   Reducing data size and radiation dose for CT colonography [J].
Hara, AK ;
Johnson, CD ;
Reed, JE ;
Ahlquist, DA ;
Nelson, H ;
Ehman, RL ;
Harmsen, WS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (05) :1181-1184