Bone-composition imaging using coherent-scatter computed tomography: Assessing bone health beyond bone mineral density

被引:64
作者
Batchelar, DL
Davidson, MTM
Dabrowski, W
Cunningham, IA
机构
[1] John P Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON N6A 5C1, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
coherent scatter; computed tomography; tissue composition; mineralization; bone mineral density (BMD); metabolic bone disease;
D O I
10.1118/1.2179151
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantitative analysis of bone composition is necessary for the accurate diagnosis and monitoring of metabolic bone diseases. Accurate assessment of the bone mineralization state is the first requirement for a comprehensive analysis. In diagnostic imaging, x-ray coherent scatter depends upon the molecular structure of tissues. Coherent-scatter computed tomography (CSCT) exploits this feature to identify tissue types in composite biological specimens. We have used CSCT to map the distributions of tissues relevant to bone disease (fat, soft tissue, collagen, and mineral) within bone-tissue phantoms and an excised cadaveric bone sample. Using a purpose-built scanner, we have measured hydroxyapatite (bone mineral) concentrations based on coherent-scatter patterns from a series of samples with varying hydroxyapatite content. The measured scatter intensity is proportional to mineral density in true g/cm(3). Repeated measurements of the hydroxyapatite concentration in each sample were within, at most, 2% of each other, revealing an excellent precision in determining hydroxyapatite concentration. All measurements were also found to be accurate to within 3% of the known values. Phantoms simulating normal, over-, and under-mineralized bone were created by mixing known masses of pure collagen and hydroxyapatite. An analysis of the composite scatter patterns gave the density of each material. For each composite, the densities were within 2% of the known values. Collagen and hydroxyapatite concentrations were also examined in a bone-mimicking phantom, incorporating other bone constituents (fat, soft tissue). Tomographic maps of the coherent-scatter properties of each specimen were reconstructed, from which material-specific images were generated. Each tissue was clearly distinguished and the collagen-mineral ratio determined from this phantom was also within 2% of the known value. Existing bone analysis techniques cannot determine the collagen-mineral ratio in intact specimens. Finally, to demonstrate the in situ potential of this technique, the mineralization state of an excised normal cadaveric radius was examined. The average collagen-mineral ratio of the cortical bone derived from material-specific images of the radius was 0.53 +/- 0.04, which is in agreement with the expected value of 0.55 for healthy bones. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:904 / 915
页数:12
相关论文
共 49 条
[1]  
[Anonymous], 1981, XRAY DIFFRACTION DIS
[2]   CRYSTALS IN CALCIFIED EPIPHYSEAL CARTILAGE AND CORTICAL BONE OF THE RAT [J].
ARSENAULT, AL ;
GRYNPAS, MD .
CALCIFIED TISSUE INTERNATIONAL, 1988, 43 (04) :219-225
[3]  
Baron R., 2003, Primer on the metabolic bone diseases and disorders of mineral metabolism, P1
[4]  
Barrett HH., 1981, RADIOLOGICAL IMAGING
[5]   Material-specific analysis using coherent-scatter imaging [J].
Batchelar, DL ;
Cunningham, IA .
MEDICAL PHYSICS, 2002, 29 (08) :1651-1660
[6]  
Bonucci E, 1998, BONE DENSITOMETRY AND OSTEOPOROSIS, P173
[7]   Total dose incurred by patients and staff from BMD measurement using a new 2D digital bone densitometer [J].
Boudousq, V ;
Kotzki, PO ;
Dinten, JM ;
Barrau, C ;
Robert-Coutant, C ;
Thomas, E ;
Goulart, DM .
OSTEOPOROSIS INTERNATIONAL, 2003, 14 (03) :263-269
[8]  
Bragg WL, 1914, P CAMB PHILOS SOC, V17, P43
[9]   Clinical evaluation of a high-resolution new peripheral quantitative computerized tomography (pQCT) scanner for the bone densitometry at the lower limbs [J].
Braun, MJ ;
Meta, MD ;
Schneider, P ;
Reiners, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08) :2279-2294
[10]  
BULLOUGH PG, 1990, ORTHOP CLIN N AM, V21, P65