High sensitivity identification of proteins by electrospray ionization tandem mass spectrometry: Initial comparison between an ion trap mass spectrometer and a triple quadrupole mass spectrometer

被引:71
作者
Figeys, D [1 ]
Aebersold, R [1 ]
机构
[1] UNIV WASHINGTON, DEPT MOL BIOTECHNOL, SEATTLE, WA 98195 USA
关键词
solid phase micro extraction; capillary zone electrophoresis; tandem mass spectrometry; microelectrospray; protein identification; two-dimensional polyacrylamide gel electrophoresis;
D O I
10.1002/elps.1150180310
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recently, we have shown that a solid-phase-microextraction/capillary electrophoresis device coupled to an electrospray ionization triple quadrupole mass spectrometer through a microelectrospray interface represents a powerful analytical system for the rapid, conclusive and sensitive identification of proteins separated by gel electrophoresis. Here we report on the successful coupling of the same device to an electrospray ionization ion trap mass spectrometer and on the comparative evaluation of the performance of the triple quadrupole and ion-trap-based systems, In the ion trap mass spectrometer-based system, using a tryptic digest of a calibrated bovine serum albumin sample, we achieved limits of detection in the single mass spectrometry (MS) and tandem MS mode, respectively, of 400 amol (if 20 mu L of solution at a concentration of 20 amol/mu L was applied). The system mras also successfully used to identify six yeast proteins isolated from a single analytical two-dimensional polyacrylamide gel. For the detection of unfragmented peptide ions both systems showed comparable sensitivity, whereas the ion-trap-based system showed superior performance with fragment ion spectra.
引用
收藏
页码:360 / 368
页数:9
相关论文
共 31 条
[11]  
FIGEYS D, 1997, IN PRESS J CHROMATOG
[12]   Characterization of peptides bound to the class I MHC molecule HLA-A2.1 by mass spectrometry (Reprinted from Science, vol 255, March 6, 1992) [J].
Hunt, Donald F. ;
Henderson, Robert A. ;
Shabanowitz, Jeffrey ;
Sakaguchi, Kazuyasu ;
Michel, Hanspeter ;
Sevilir, Noelle ;
Cox, Andrea L. ;
Appella, Ettore ;
Engelhard, Victor H. .
JOURNAL OF IMMUNOLOGY, 2007, 179 (05) :2669-2671
[13]   Application of reversed-phase high-performance liquid chromatography and capillary zone electrophoresis to the peptide mapping of pepsin isoenzymes [J].
Hynek, R ;
Kasicka, V ;
Kucerova, Z ;
Kas, J .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 681 (01) :37-45
[14]   INVESTIGATIONS OF THE ELECTROSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
IKONOMOU, MG ;
BLADES, AT ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1990, 62 (09) :957-967
[15]   Development of electrophoretic conditions for the characterization of protein glycoforms by capillary electrophoresis electrospray mass spectrometry [J].
Kelly, JF ;
Locke, SJ ;
Ramaley, L ;
Thibault, P .
JOURNAL OF CHROMATOGRAPHY A, 1996, 720 (1-2) :409-427
[16]  
LOPEZ LL, 1996, LCQ GETTING STARTED
[17]   ERROR TOLERANT IDENTIFICATION OF PEPTIDES IN SEQUENCE DATABASES BY PEPTIDE SEQUENCE TAGS [J].
MANN, M ;
WILM, M .
ANALYTICAL CHEMISTRY, 1994, 66 (24) :4390-4399
[18]   Capillary column high-performance liquid chromatographic electrospray ionization triple-stage quadrupole mass spectrometric analysis of proteins separated by two-dimensional polyacrylamide gel electrophoresis - Application to cerebellar protein mapping [J].
Nakayama, H ;
Uchida, K ;
Shinkai, F ;
Shinoda, T ;
Okuyama, T ;
Seta, K ;
Isobe, T .
JOURNAL OF CHROMATOGRAPHY A, 1996, 730 (1-2) :279-287
[19]   MASS-SPECTROMETRIC APPROACHES FOR THE IDENTIFICATION OF GEL-SEPARATED PROTEINS [J].
PATTERSON, SD ;
AEBERSOLD, R .
ELECTROPHORESIS, 1995, 16 (10) :1791-1814
[20]   IMPROVED ELECTROSPRAY IONIZATION INTERFACE FOR CAPILLARY ZONE ELECTROPHORESIS - MASS-SPECTROMETRY [J].
SMITH, RD ;
BARINAGA, CJ ;
UDSETH, HR .
ANALYTICAL CHEMISTRY, 1988, 60 (18) :1948-1952