Vascular Compliance Changes of the Coronary Vessel Wall After Bioresorbable Vascular Scaffold Implantation in the Treated and Adjacent Segments

被引:60
作者
Brugaletta, Salvatore [5 ]
Gogas, Bill D.
Garcia-Garcia, Hector M. [3 ]
Farooq, Vasim
Girasis, Chrysafios
Heo, Jung Ho
van Geuns, Robert Jan
de Bruyne, Bernard [6 ]
Dudek, Dariuz [7 ]
Koolen, Jacques [4 ]
Smits, Pieter [2 ]
Veldhof, Susan [8 ]
Rapoza, Richard [9 ]
Onuma, Yoshinobu
Ormiston, John [10 ]
Serruys, Patrick W. [1 ]
机构
[1] Erasmus MC, Thoraxctr, Head Intervent Cardiol Dept, NL-3015 CE Rotterdam, Netherlands
[2] Maasstad Hosp, Rotterdam, Netherlands
[3] Cardialysis BV, Rotterdam, Netherlands
[4] Catharina Hosp, Eindhoven, Netherlands
[5] Univ Hosp Clin, Thorax Inst, Dept Cardiol, Barcelona, Spain
[6] Ctr Cardiovasc, Aalst, Belgium
[7] Jagiellonian Univ, Krakow, Poland
[8] Abbott Vasc, Diegem, Belgium
[9] Abbott Vasc, Santa Clara, CA USA
[10] Auckland City Hosp, Auckland, New Zealand
关键词
ABSORB; Poly-lactide; Vascular compliance; OPTICAL COHERENCE TOMOGRAPHY; EVEROLIMUS-ELUTING STENT; ABSORB CLINICAL-TRIAL; COMPLIANCE MISMATCH; SHEAR-STRESS; INTRAVASCULAR PALPOGRAPHY; IMAGING OUTCOMES; NITRIC-OXIDE; REVISION; 1.0; BLOOD-FLOW;
D O I
10.1253/circj.CJ-11-1416
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Background: Implantation of a metallic prosthesis creates local stiffness with a subsequent mismatch in the compliance of the vessel wall, disturbances in flow and heterogeneous distribution of wall shear stress. Polymeric bioresorbable ABSORB scaffolds have less stiffness than metallic platform stents. We sought to analyze the mismatch in vascular compliance after ABSORB implantation and its long-term resolution with bioresorption. Methods and Results: A total of 83 patients from the ABSORB trials underwent palpography investigations (30 and 53 patients from ABSORB Cohorts A and B, respectively) to measure the compliance of the scaffolded and adjacent segments at various time points (from pre-implantation up to 24 months). The mean of the maximum strain values was calculated per segment by utilizing the Rotterdam Classification (ROC) score and expressed as ROC/mm. Scaffold implantation lead to a significant decrease in vascular compliance (median [IQR]) at the scaffolded segment (from 0.37 [0.24-0.45] to 0.14 [0.09-0.23], P<0.001) with mismatch in compliance in a paired analysis between the scaffolded and adjacent segments (proximal: 0.23 [0.12-0.34], scaffold: 0.12 [0.07-0.19], distal: 0.15 [0.05-0.26], P=0.042). This reported compliance mismatch disappears at short- and mid-term follow-up. Conclusions: The ABSORB scaffold decreases vascular compliance at the site of scaffold implantation. A compliance mismatch is evident immediately post-implantation and in contrast to metallic stents disappears in the mid-term, likely leading to a normalization of the rheological behavior of the scaffolded segment. (Circ J 2012; 76: 1616-1623)
引用
收藏
页码:1616 / 1623
页数:8
相关论文
共 40 条
[1]
CYCLIC STRAIN UP-REGULATES NITRIC-OXIDE SYNTHASE IN CULTURED BOVINE AORTIC ENDOTHELIAL-CELLS [J].
AWOLESI, MA ;
SESSA, WC ;
SUMPIO, BE .
JOURNAL OF CLINICAL INVESTIGATION, 1995, 96 (03) :1449-1454
[2]
eNOS Activation by Physical Forces: From Short-Term Regulation of Contraction to Chronic Remodeling of Cardiovascular Tissues [J].
Balligand, J. -L. ;
Feron, O. ;
Dessy, C. .
PHYSIOLOGICAL REVIEWS, 2009, 89 (02) :481-534
[3]
Experimental study of laminar blood flow through an artery treated by a stent implantation: characterisation of intra-stent wall shear stress [J].
Benard, N ;
Coisne, D ;
Donal, E ;
Perrault, R .
JOURNAL OF BIOMECHANICS, 2003, 36 (07) :991-998
[4]
Serail In Vivo Intravascular Ultrasound-Based Echogenicity Changes of Everolimus-Eluting Bioresorbable Vascular Scaffold During the First 12 Months After Implantation [J].
Brugaletta, Salvatore ;
Gomez-Lara, Josep ;
Serruys, Patrick W. ;
Farooq, Vasim ;
van Geuns, Robert Jan ;
Thuesen, Leif ;
Dudek, Dariusz ;
Koolen, Jacques ;
Chevalier, Bernard ;
McClean, Dougal ;
Windecker, Stephan ;
Smits, Pieter C. ;
de Bruyne, Bernard ;
Whitbourn, Robert ;
Meredith, Ian ;
van Domburg, Ron T. ;
Sihan, Kenij ;
de Winter, Sebastiaan ;
Veldhof, Susan ;
Miquel-Hebert, Karine ;
Rapoza, Richard ;
Garcia-Garcia, Hector M. ;
Ormiston, John A. ;
Bruining, Nico .
JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (12) :1281-1289
[5]
Comparison between the first and second generation bioresorbable vascular scaffolds: a six month virtual histology study [J].
Brugaletta, Salvatore ;
Garcia-Garcia, Hector M. ;
Diletti, Roberto ;
Gomez-Lara, Josep ;
Garg, Scot ;
Onuma, Yoshinobu ;
Shin, Eun-Seok ;
van Geuns, Robert Jan ;
de Bruyne, Bernard ;
Dudek, Dariusz ;
Thuesen, Leif ;
Chevalier, Bernard ;
McClean, Dougal ;
Windecker, Stephan ;
Whitbourn, Robert ;
Dorange, Cecile ;
Veldhof, Susan ;
Rapoza, Richard ;
Sudhir, Krishnankutty ;
Bruining, Nico ;
Ormiston, John A. ;
Serruys, Patrick W. .
EUROINTERVENTION, 2011, 6 (09) :1110-1116
[6]
Assessment of the absorption process following bioabsorbable everolimus-eluting stent implantation: temporal changes in strain values and tissue composition using intravascular ultrasound radiofrequency data analysis A substudy of the ABSORB clinical trial [J].
Garcia-Garcia, Hector M. ;
Gonzalo, Nieves ;
Pawar, Ravindra ;
Kukreja, Neville ;
Dudek, Dariusz ;
Thuesen, Leif ;
Ormiston, John A. ;
Regar, Evelyn ;
Serruys, Patrick W. .
EUROINTERVENTION, 2009, 4 (04) :443-448
[7]
Coronary Stents Current Status [J].
Garg, Scot ;
Serruys, Patrick W. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (10) :S1-S42
[8]
A comparative assessment by optical coherence tomography of the performance of the first and second generation of the everolimus-eluting bioresorbable vascular scaffolds [J].
Gomez-Lara, Josep ;
Brugaletta, Salvatore ;
Diletti, Roberto ;
Garg, Scot ;
Onuma, Yoshinobu ;
Gogas, Bill D. ;
van Geuns, Robert Jan ;
Dorange, Cecile ;
Veldhof, Susan ;
Rapoza, Richard ;
Whitbourn, Robert ;
Windecker, Stephan ;
Garcia-Garcia, Hector M. ;
Regar, Evelyn ;
Serruys, Patrick W. .
EUROPEAN HEART JOURNAL, 2011, 32 (03) :294-304
[9]
Effects of static and cyclic loading in regulating extracellular matrix synthesis by cardiovascular cells [J].
Gupta, Vishal ;
Grande-Allen, K. Jane .
CARDIOVASCULAR RESEARCH, 2006, 72 (03) :375-383
[10]
Spatial, Distribution and Temporal Evolution of Scattering Centers by Optical Coherence Tomography in the Poly(L-Lactide) Backbone of a Bioresorbable Vascular Scaffold [J].
Gutierrez-Chico, Juan Luis ;
Radu, Maria D. ;
Diletti, Roberto ;
Sheehy, Alexander ;
Kossuth, Mary Beth ;
Oberhauser, James P. ;
Glauser, Thierry ;
Harrington, Joel ;
Rapoza, Richard J. ;
Onuma, Yoshinobu ;
Serruys, Patrick W. .
CIRCULATION JOURNAL, 2012, 76 (02) :342-350