Design of piezoelectric inchworm actuator and compliant end-effector for Minimally Invasive Surgery

被引:12
作者
Canfield, S [1 ]
Edinger, B [1 ]
Frecker, M [1 ]
Koopmann, G [1 ]
机构
[1] Penn State Univ, Dept Mech & Nucl Engn, University Pk, PA 16802 USA
来源
SMART STRUCTURES AND MATERIALS 1999: SMART STRUCTURES AND INTEGRATED SYSTEMS, PTS 1 AND 2 | 1999年 / 3668卷
关键词
Minimally Invasive Surgery (MIS); compliant mechanism; piezoelectric actuator; inchworm actuator;
D O I
10.1117/12.350759
中图分类号
O42 [声学];
学科分类号
070206 [声学]; 082403 [水声工程];
摘要
Recent advances in robotics, tele-robotics, smart material actuators, and mechatronics raise new possibilities for innovative developments in millimeter-scale robotics capable of manipulating objects only fractions of a millimeter in size. These advances can have a wide range of applications in the biomedical community. A potential application of this technology is in minimally invasive surgery (MIS). The focus of this paper is the development of a single degree of freedom prototype to demonstrate the viability of smart materials, force feedback and compliant mechanisms for minimally invasive surgery. The prototype is a compliant gripper that is 7-mm by 17-mm, made from a single piece of titanium that is designed to function as a needle driver for small scale suturing. A custom designed piezoelectric "inchworm" actuator drives the gripper. The integrated system is computer controlled providing a user interface device capable of force feedback. The design methodology described draws from recent advances in three emerging fields in engineering: design of innovative tools for MIS, design of compliant mechanisms, and design of smart materials and actuators. The focus of this paper is on the design of a millimeter-scale inchworm actuator for use with a compliant end effector in MIS.
引用
收藏
页码:835 / 843
页数:9
相关论文
共 24 条
[1]
Ananthasuresh G. K., 1994, Technical Digest. Solid-State Sensor and Actuator Workshop, P189
[2]
ANANTHASURESH GK, 1994, P 1994 ASME WINT DSC, V55
[3]
Integrated microendeffector for micromanipulation [J].
Arai, F ;
Andou, D ;
Nonoda, Y ;
Fukuda, T ;
Iwata, H ;
Itoigawa, K .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 1998, 3 (01) :17-23
[4]
A new tool for minor-access surgery [J].
Balazs, M ;
Feussner, H ;
Hirzinger, G ;
Omote, K ;
Ungeheuer, A .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1998, 17 (03) :45-48
[5]
A silicon force sensor for robotics and medicine [J].
Beebe, DJ ;
Hsieh, AS ;
Denton, DD ;
Radwin, RG .
SENSORS AND ACTUATORS A-PHYSICAL, 1995, 50 (1-2) :55-65
[6]
BICCHI A, 1996, IEEE INT C ROB AUT M
[7]
A technique for measuring contact force distribution in minimally invasive surgical procedures [J].
Brett, PN ;
Stone, RSW .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (04) :309-316
[8]
CAO C, 1996, KINESIOLOGY, P224
[9]
Force feedback for surgical simulation [J].
Chen, E ;
Marcus, B .
PROCEEDINGS OF THE IEEE, 1998, 86 (03) :524-530
[10]
SURGICAL APPLICATORS OF MILLI-ROBOTS [J].
COHN, MB ;
CRAWFORD, LS ;
WENDLANDT, JM ;
SASTRY, SS .
JOURNAL OF ROBOTIC SYSTEMS, 1995, 12 (06) :401-416