Performance evaluation of the Philips "Gemini" PET/CT system

被引:20
作者
Gregory, R [1 ]
Partridge, M [1 ]
Flower, MA [1 ]
机构
[1] Royal Marsden NHS Fdn Trust, Joint Dept Phys, Inst Canc Res, Surrey SM2 5PT, England
关键词
D O I
10.1109/TNS.2005.862968
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 [电气工程]; 0809 [电子科学与技术];
摘要
Methods to test the practical performance of the Philips Gemini PET/CT system during clinical imaging are described and results presented. The test methods used were based on the NEMA standards and those suggested by a task group of the Commission of European Communities (EEC). These were performed using the EEC emission phantom, and phantoms provided by Philips. Scans were acquired using the routine clinical protocols. Images were reconstructed using a 3D row action maximum likelihood algorithm (RAMLA). Attenuation correction (AC) was applied using CT data (CTAC) and Cs-137 source transmission scans (CsAC). Images can be acquired with the PET and CT gantries closed or open. Results of tests on the gantry alignment show that the static offsets varied by a maximum of 4.5 rum when the system was first installed, but as the floor has settled these variations have decreased to a maximum of 2.5 mm. The mean negative nonuniformity was -4.8 +/- 1.1% and -5.3 +/- 1.1% for CsAC and CTAC respectively and the mean positive nonuniformity was 4.7 +/- 1.4% and 5.5 +/- 1.6%. Scatter fraction measurements were made in the EEC body phantom. The reconstructed scatter fractions were 0.18 and 0.16 with and without out-of-field-of-view activity respectively (+/- OFOVA) for both CsAC and CTAC images. The sinogram-derived (NEMA NU 2-1994) scatter fraction was 0.44 and 0.43 OFOVA. At the centre of the field of view (FOV) the transverse spatial resolution (SR) was 5.0 mm in air (5.0 rum in water) and the axial SR was 6.0 mm (6.8 mm). 10 cm away from the centre the transverse radial SR was 5.4 mm (5.3 mm), the transverse tangential SR was 5.2 rum (5.4 mm) and the axial SR was 6.6 mm (7.2 mm). The recovery coefficients demonstrate the partial volume effect. The AC accuracy was similar in water (both 0.2 +/- 0.1%) and Teflon [10.9 +/- 1.9% (CTAC) and 10.0 +/- 2.0% (CsAC)], for both types of AC, but very different in air (14.3 +/- 2.2% (CTAC) and 31.3 +/- 1.5% (CsAC)]. If the transmission maps were not segmented prior to AC these gave much higher and very different residual AC errors. The peak noise equivalent count rate was 45.2 kcps at 184 MBq and 25.2 kcps at 127 MBq OFOVA. The system sensitivity to true and scattered counts was 34.1 kcps/(kBq/cm(3)) and to true counts was 19.4 kcps/(kBq/cm(3)).
引用
收藏
页码:93 / 101
页数:9
相关论文
共 11 条
[1]
Optimization of a fully 3D single scatter simulation algorithm for 3D PET [J].
Accorsi, R ;
Adam, LE ;
Werner, ME ;
Karp, JS .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12) :2577-2598
[2]
Performance evaluation of the new whole-body PET/CT scanner: Discovery ST [J].
Bettinardi, V ;
Danna, M ;
Savi, A ;
Lecchi, M ;
Castiglioni, I ;
Gilardi, MC ;
Bammer, H ;
Lucignani, G ;
Fazio, F .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (06) :867-881
[3]
A row-action alternative to the EM algorithm for maximizing likelihoods in emission tomography [J].
Browne, J ;
DePierro, AR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (05) :687-699
[4]
CRONIN B, 2004, RAD MAG, V30, P35
[5]
Guzzardi R, 1991, J Nucl Biol Med, V35, P141
[6]
KIM JS, 2004, J NUCL MED S, V45, pP101
[7]
Lartizien C, 2002, J NUCL MED, V43, P1268
[8]
LODGE MA, 2004, J NUCL MED S, V45, pP425
[9]
*NEMA, 1994, NEMA NU 2 STAND P NU, V2
[10]
*NEMA, 2001, NEMA NU 2 STAND P NU, V2