Optimization of a fully 3D single scatter simulation algorithm for 3D PET

被引:100
作者
Accorsi, R
Adam, LE
Werner, ME
Karp, JS
机构
[1] Childrens Hosp Philadelphia, Dept Radiol, Div Nucl Med, Philadelphia, PA 19104 USA
[2] Univ Penn, Sch Med, Dept Radiol, Philadelphia, PA 19104 USA
[3] Philips Med Syst, Philadelphia, PA 19104 USA
关键词
D O I
10.1088/0031-9155/49/12/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We describe a new implementation of a single scatter simulation (SSS) algorithm for the prediction and correction of scatter in 3D PET. In this implementation, out of field of view (FoV) scatter and activity, side shields and oblique tilts are explicitly modelled. Comparison of SSS predictions with Monte Carlo simulations and experimental data from uniform, line and cold-bar phantoms showed that the code is accurate for uniform as well as asymmetric objects and can model different energy resolution crystals and low level discriminator (LLD) settings. Absolute quantitation studies show that for most applications, the code provides a better scatter estimate than the tail-fitting scatter correction method currently in use at our institution. Several parameters such as the density of scatter points, the number of scatter distribution sampling points and the axial extent of the FoV were optimized to minimize execution time, with particular emphasis on patient studies. Development and optimization were carried out in the case of GSO-based scanners, which enjoy relatively good energy resolution. SSS estimates for scanners with lower energy resolution may result in different agreement, especially because of a higher fraction of multiple scatter events. The algorithm was applied to a brain phantom as well as to clinical whole-body studies. It proved robust in the case of large patients, where the scatter fraction increases. The execution time, inclusive of interpolation, is typically under 5 min for a whole-body study (axial FoV: 81 cm) of a 100 kg patient.
引用
收藏
页码:2577 / 2598
页数:22
相关论文
共 18 条
  • [1] Accorsi R., 2002, 2002 IEEE NUCL SCI S
  • [2] Energy-based scatter correction for 3-D PET scanners using NaI(Tl) detectors
    Adam, LE
    Karp, JS
    Freifelder, R
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 513 - 521
  • [3] Investigation of scattered radiation in 3D whole-body positron emission tomography using Monte Carlo simulations
    Adam, LE
    Karp, JS
    Brix, G
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12) : 2879 - 2895
  • [4] Adam LE, 2001, J NUCL MED, V42, P1821
  • [5] A CONVOLUTION-SUBTRACTION SCATTER CORRECTION METHOD FOR 3D PET
    BAILEY, DL
    MEIKLE, SR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) : 411 - 424
  • [6] Bendriem B., 1998, THEORY PRACTICE 3D P, DOI [10.1007/978-94-017-3475-2, DOI 10.1007/978-94-017-3475-2]
  • [7] Application of the row action maximum likelihood algorithm with spherical basis functions to clinical PET imaging
    Daube-Witherspoon, ME
    Matej, S
    Karp, JS
    Lewitt, RM
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (01) : 24 - 30
  • [8] EVANS RD, 1955, ATOMIC NUCLEUS, P690
  • [9] GOGGIN AS, 1994, NUCLEAR SCIENCE SYMPOSIUM & MEDICAL IMAGING CONFERENCE - 1994 IEEE CONFERENCE RECORD, VOLS 1-4, P1609
  • [10] Performance analysis of an improved 3-D PET Monte Carlo simulation and scatter correction
    Holdsworth, CH
    Levin, CS
    Janecek, M
    Dahlbom, M
    Hoffman, EJ
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) : 83 - 89