Energy-based scatter correction for 3-D PET scanners using NaI(Tl) detectors

被引:23
作者
Adam, LE [1 ]
Karp, JS [1 ]
Freifelder, R [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
关键词
NaI(Tl) PET; positron emission tomography (PET); quantitation; scatter correction;
D O I
10.1109/42.870261
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Earlier investigations with EGO positron emission tomography (PET) scanners showed that the scatter correction technique based on multiple acquisitions with different energy windows are problematic to implement because of the poor energy resolution of EGO (22%), particularly for whole-body studies. We believe that these methods are likely to work better with NaI(TI) because of the better energy resolution achievable with NaI(TI) detectors (10%), Therefore, we investigate two different choices for the energy window, a low-energy window (LEW) on the Compton spectrum at 400-450 keV, and a high-energy window (HEW) within the photopeak (lower threshold above 511 keV). The results obtained for our three-dimensional (3-D) (septa-less) whole-body scanners [axial field of view (FOV) of 12.8 cm and 25.6 cm] as well as for our 3-D brain scanner (axial FOV of 25.6 cm) show an accurate prediction of the scatter distribution for the estimation of trues method (ETM) using a HEW, leading to a significant reduction of the scatter contamination. The dual-energy window (DEW) technique using a LEW is shown to be intrinsically wrong; in particular, it fails for line source and bar phantom measurements, However, the method is able to produce good results for homogeneous activity distributions. Both methods are easy to implement, are fast, have a low noise propagation, and will be applicable to other PET scanners with good energy resolution and stability, such as hybrid NaI(TI) PET/SPECT dual-head cameras and future PET cameras with GSO or LSO scintillators.
引用
收藏
页码:513 / 521
页数:9
相关论文
共 31 条
[1]   Investigation of scattered radiation in 3D whole-body positron emission tomography using Monte Carlo simulations [J].
Adam, LE ;
Karp, JS ;
Brix, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (12) :2879-2895
[2]  
ADAM LE, 1997, THESIS U HEIDELBERG
[3]  
ADAM LE, 1998, P IEEE MED IM C REC, V3, P2011
[4]   A CONVOLUTION-SUBTRACTION SCATTER CORRECTION METHOD FOR 3D PET [J].
BAILEY, DL ;
MEIKLE, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :411-424
[5]  
BENDRIEM B, 1993, NUCLEAR SCIENCE SYMPOSIUM & MEDICAL IMAGING CONFERENCE, VOLS 1-3, P1779, DOI 10.1109/NSSMIC.1993.373598
[6]  
Bendriem B., 1998, THEORY PRACTICE 3D P, DOI [10.1007/978-94-017-3475-2, DOI 10.1007/978-94-017-3475-2]
[7]  
BENTOURKIA M, 1995, J NUCL MED, V36, P121
[8]   CORRECTION FOR SCATTERED RADIATION IN A RING DETECTOR POSITRON CAMERA BY INTEGRAL TRANSFORMATION OF THE PROJECTIONS [J].
BERGSTROM, M ;
ERIKSSON, L ;
BOHM, C ;
BLOMQVIST, G ;
LITTON, J .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (01) :42-50
[9]  
FREIFELDER R, 1992, P IEEE MIC C REC, V2, P888
[10]   Correction for scatter in 3D brain PET using a dual energy window method [J].
Grootoonk, S ;
Spinks, TJ ;
Sashin, D ;
Spyrou, NM ;
Jones, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (12) :2757-2774