Effects of Precompression on Elasticity Imaging of the Breast Development of a Clinically Useful Semiquantitative Method of Precompression Assessment

被引:171
作者
Barr, Richard G. [1 ,2 ]
Zhang, Zheng [3 ]
机构
[1] Radiol Consultants Inc, Youngstown, OH 44512 USA
[2] NE Ohio Med Univ, Dept Radiol, Rootstown, OH USA
[3] Brown Univ, Dept Biostat, Providence, RI 02912 USA
关键词
breast elastography; precompression; shear wave imaging; strain imaging; ELASTOGRAPHY; TISSUES; US;
D O I
10.7863/jum.2012.31.6.895
中图分类号
O42 [声学];
学科分类号
070206 [声学];
摘要
Objectives-Elastography of the breast is a new technique for characterization of breast lesions. The reproducibility of elastographic techniques has been questioned. Precompression is known to effect elastographic results. This study determined the effect of precompression on clinical images and proposes a method to semiquantify the amount of precompression applied. Methods-Ten patients with different breast tissue types were evaluated with shear wave and strain elastography with varying amounts of precompression. The changes in the shear wave speed and images were documented. A semiquantitative method for determining the amount of precompression applied is presented. The reproducibility of the technique was determine by repeated measurements by 3 sonographers. Results-Precompression substantially changes the elastographic results of patient images on both strain and shear wave elastography. Fat can have the same elasticity as cancer with clinically possible amounts of precompression. The proposed method for determining the amount of precompression applied has variability of less than 10%, which is within the error of the technique and would not affect clinical results. Four zones of precompression are identified, which are useful for explaining the effects of precompression on both strain and shear wave imaging. Conclusions-Precompression is a substantial factor in obtaining accurate results with elastography. A proposed simple, easily applied technique can be used to semiquantify the amount of precompression applied. Precompression should be minimized in obtaining breast clinical images.
引用
收藏
页码:895 / 902
页数:8
相关论文
共 17 条
[1]
Breast Lesions: Quantitative Elastography with Supersonic Shear Imaging-Preliminary Results [J].
Athanasiou, Alexandra ;
Tardivon, Anne ;
Tanter, Mickael ;
Sigal-Zafrani, Brigitte ;
Bercoff, Jeremy ;
Eux, Thomas Deffi ;
Gennisson, Jean-Luc ;
Fink, Mathias ;
Neuenschwander, Sylvia .
RADIOLOGY, 2010, 256 (01) :297-303
[2]
Shear Wave Imaging of the Breast Still on the Learning Curve [J].
Barr, Richard G. .
JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (03) :347-350
[3]
Evaluation of Breast Lesions Using Sonographic Elasticity Imaging A Multicenter Trial [J].
Barr, Richard G. ;
Destounis, Stamatia ;
Lackey, Logan B., II ;
Svensson, William E. ;
Balleyguier, Corinne ;
Smith, Carmel .
JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (02) :281-287
[4]
The Utility of the "Bull's-Eye" Artifact on Breast Elasticity Imaging in Reducing Breast Lesion Biopsy Rate [J].
Barr, Richard G. ;
Lackey, Amanda E. .
ULTRASOUND QUARTERLY, 2011, 27 (03) :151-155
[5]
Real-Time Ultrasound Elasticity of the Breast Initial Clinical Results [J].
Barr, Richard G. .
ULTRASOUND QUARTERLY, 2010, 26 (02) :61-66
[6]
Supersonic shear imaging: A new technique for soft tissue elasticity mapping [J].
Bercoff, J ;
Tanter, M ;
Fink, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (04) :396-409
[7]
Shear-wave Elastography Improves the Specificity of Breast US: The BE1 Multinational Study of 939 Masses [J].
Berg, Wendie A. ;
Cosgrove, David O. ;
Dore, Caroline J. ;
Schaefer, Fritz K. W. ;
Svensson, William E. ;
Hooley, Regina J. ;
Ohlinger, Ralf ;
Mendelson, Ellen B. ;
Balu-Maestro, Catherine ;
Locatelli, Martina ;
Tourasse, Christophe ;
Cavanaugh, Barbara C. ;
Juhan, Valerie ;
Stavros, A. Thomas ;
Tardivon, Anne ;
Gay, Joel ;
Henry, Jean-Pierre ;
Cohen-Bacrie, Claude .
RADIOLOGY, 2012, 262 (02) :435-449
[8]
ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES [J].
GLUER, CC ;
BLAKE, G ;
LU, Y ;
BLUNT, BA ;
JERGAS, M ;
GENANT, HK .
OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) :262-270
[9]
Reproducibility of Shear Wave Velocity Measurements by Acoustic Radiation Force Impulse Imaging of the Liver A Study in Healthy Volunteers [J].
Guzman-Aroca, Florentina ;
Reus, Manuel ;
Berna-Serna, Juan D. ;
Serrano, Laura ;
Serrano, Cristina ;
Gilabert, Amparo ;
Cepero, Angela .
JOURNAL OF ULTRASOUND IN MEDICINE, 2011, 30 (07) :975-979
[10]
Reliable Measurement Procedure of Virtual Touch Tissue Quantification With Acoustic Radiation Force Impulse Imaging [J].
Kaminuma, Chie ;
Tsushima, Yoshito ;
Matsumoto, Noriko ;
Kurabayashi, Takemi ;
Taketomi-Takahashi, Ayako ;
Endo, Keigo .
JOURNAL OF ULTRASOUND IN MEDICINE, 2011, 30 (06) :745-751