Soft-copy mammographic readings with different computer-assisted detection cuing environments: Preliminary findings

被引:79
作者
Zheng, B
Ganott, MA
Britton, CA
Hakim, CM
Hardesty, LA
Chang, TS
Rockette, HE
Gur, D
机构
[1] Univ Pittsburgh, Dept Radiol, Div Imaging Res, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Dept Biostat, Pittsburgh, PA 15213 USA
[3] Univ Pittsburgh, Med Ctr, Magee Womens Hosp, Hlth Syst, Pittsburgh, PA 15260 USA
关键词
breast neoplasms; diagnosis; cancer screening; computers; diagnostic aid; diagnostic radiology; observer performance;
D O I
10.1148/radiol.2213010308
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the performance of radiologists in the detection of masses and microcalcification clusters on digitized mammograms by using different computer-assisted detection (CAD) cuing environments. MATERIALS AND METHODS: Two hundred nine digitized mammograms depicting 57 verified masses and 38 microcalcification clusters in 85 positive and 35 negative cases were interpreted independently by seven radiologists using five display modes. Except for the first mode, for which no CAD results were provided, suspicious regions identified with a CAD scheme were cued in all the other modes by using a combination of two cuing sensitivities (90% and 50%) and two false-positive rates (0.5 and 2.0 per image). A receiver operating characteristic study was performed by using soft-copy images. RESULTS: CAD cuing at 90% sensitivity and a rate of 0.5 false-positive region per image improved observer performance levels significantly (P < .01). As accuracy of CAD cuing decreased so did observer performances (P < .01). Cuing specificity affected mass detection more significantly, while cuing sensitivity affected detection of microcalcification clusters more significantly (P < .01). Reduction of cuing sensitivity and specificity significantly increased false-negative rates in noncued areas (P < .05). Trends were consistent for all observers. CONCLUSION: CAD systems have the potential to significantly improve diagnostic performance in mammography. However, poorly performing schemes could adversely affect observer performance in both cued and noncued areas.
引用
收藏
页码:633 / 640
页数:8
相关论文
共 34 条
[1]   ANALYSIS OF CANCERS MISSED AT SCREENING MAMMOGRAPHY [J].
BIRD, RE ;
WALLACE, TW ;
YANKASKAS, BC .
RADIOLOGY, 1992, 184 (03) :613-617
[2]  
BRAKE GM, 1998, RADIOLOGY, V207, P465
[3]  
Burhenne LJW, 2000, RADIOLOGY, V215, P554
[4]   DIGITIZATION REQUIREMENTS IN MAMMOGRAPHY - EFFECTS ON COMPUTER-AIDED DETECTION OF MICROCALCIFICATIONS [J].
CHAN, HP ;
NIKLASON, LT ;
IKEDA, DM ;
LAM, KL ;
ADLER, DD .
MEDICAL PHYSICS, 1994, 21 (07) :1203-1211
[5]   Improvement of radiologists' characterization of mammographic masses by using computer-aided diagnosis: An ROC study [J].
Chan, HP ;
Sahiner, B ;
Helvie, MA ;
Petrick, N ;
Roubidoux, MA ;
Wilson, TE ;
Adler, DD ;
Paramagul, C ;
Newman, JS ;
Sanjay-Gopal, S .
RADIOLOGY, 1999, 212 (03) :817-827
[6]  
Doi T, 1999, INT CONGR SER, V1182, P201
[7]   American College of Radiology guidelines for breast cancer screening [J].
Feig, SA ;
D'Orsi, CJ ;
Hendrick, RE ;
Jackson, VP ;
Kopans, DB ;
Monsees, B ;
Sickles, EA ;
Stelling, CB ;
Zinninger, M ;
Wilcox-Buchalla, P .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) :29-33
[8]  
Funovics M, 1998, Wien Med Wochenschr, V148, P321
[9]  
Hendee WR, 1999, MED PHYS, V26, P1, DOI 10.1118/1.598473
[10]   Improving breast cancer diagnosis with computer-aided diagnosis [J].
Jiang, YL ;
Nishikawa, RM ;
Schmidt, RA ;
Metz, CE ;
Giger, ML ;
Doi, K .
ACADEMIC RADIOLOGY, 1999, 6 (01) :22-33