Periodontal probe precision using 4 different periodontal probes

被引:42
作者
Mayfield, L
Bratthall, G
Attstrom, R
机构
[1] Department of Periodontology, Faculty of Dentistry, Lund University, Malmo
关键词
reproducibility; probing pocket depth; pressure-sensitive periodontal probes;
D O I
10.1111/j.1600-051X.1996.tb00538.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to compare the relative intra- and inter-examiner reproducibility of 4 different periodontal probes. (1) The Hu-Friedy LL 20 Probe, a manual probe. (2) The Vivacare TPS Probe, a plastic manual probe with a standardised pressure of 0.20 N. (3) The Vine Valley Prober an electronic probe using a standardised pressure of 0.25 N. 4. The Peri Probe Comp, a computerised electronic probe with a controlled pressure of 0.45 N in 2 mm pockets to 0.25 N in 13 mm pockets. Duplicate probing measurements were taken by 2 examiners in 10 patients on 3 index teeth, 1 molar, 1 premolar and 1 incisor at 6 sites per tooth. Teeth were selected to incorporate both shallow (<5 mm) and deeper (greater than or equal to 5 mm) periodontal sites. The order of probes and examiners were changed in a systematic manner and measurements were repeated 1 week later to avoid bias due to examiner memory. Results show that the manual probe had the lowest degree of variation. with a correlation coefficient of 0.83. The manual and Peri Probe Comp frequently recorded deeper probing pocket depths compared to the TPS and Vine Valley probes, The results may have been influenced by the lack of familiarity with the automated probes.
引用
收藏
页码:76 / 82
页数:7
相关论文
共 29 条
  • [1] MICROSCOPIC EVALUATION OF CLINICAL MEASUREMENTS OF CONNECTIVE-TISSUE ATTACHMENT LEVELS
    ARMITAGE, GC
    SVANBERG, GK
    LOE, H
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1977, 4 (03) : 173 - 190
  • [2] REPRODUCIBILITY OF PROBING ATTACHMENT LEVEL MEASUREMENTS
    BADERSTEN, A
    NILVEUS, R
    EGELBERG, J
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1984, 11 (07) : 475 - 485
  • [3] Becherer C F, 1993, Schweiz Monatsschr Zahnmed, V103, P715
  • [4] DEPTH OF PERIODONTAL PROBE PENETRATION RELATED TO CLINICAL AND HISTOLOGIC SIGNS OF GINGIVAL INFLAMMATION
    CATON, J
    GREENSTEIN, G
    POLSON, AM
    [J]. JOURNAL OF PERIODONTOLOGY, 1981, 52 (10) : 626 - 629
  • [5] EVALUATION OF PERIODONTAL PROBING FORCES
    FREED, HK
    GAPPER, RL
    KALKWARF, KL
    [J]. JOURNAL OF PERIODONTOLOGY, 1983, 54 (08) : 488 - 492
  • [6] GABATHULER H, 1971, HELV ODONTOL ACTA, V15, P114
  • [7] DESCRIPTION AND CLINICAL-EVALUATION OF A NEW COMPUTERIZED PERIODONTAL PROBE - THE FLORIDA PROBE
    GIBBS, CH
    HIRSCHFELD, JW
    LEE, JG
    LOW, SB
    MAGNUSSON, I
    THOUSAND, RR
    YERNENI, P
    CLARK, WB
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (02) : 137 - 144
  • [8] PATTERNS OF PROGRESSION AND REGRESSION OF ADVANCED DESTRUCTIVE PERIODONTAL-DISEASE
    GOODSON, JM
    TANNER, ACR
    HAFFAJEE, AD
    SORNBERGER, GC
    SOCRANSKY, SS
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1982, 9 (06) : 472 - 481
  • [9] HUNTER F M, 1991, Journal of Dental Research, V70, P587
  • [10] COMPARISON OF MANUAL AND PRESSURE-CONTROLLED PERIODONTAL PROBING
    KALKWARF, KL
    KALDAHL, WB
    PATIL, KD
    [J]. JOURNAL OF PERIODONTOLOGY, 1986, 57 (08) : 467 - 471