Periodontal probe precision using 4 different periodontal probes

被引:42
作者
Mayfield, L
Bratthall, G
Attstrom, R
机构
[1] Department of Periodontology, Faculty of Dentistry, Lund University, Malmo
关键词
reproducibility; probing pocket depth; pressure-sensitive periodontal probes;
D O I
10.1111/j.1600-051X.1996.tb00538.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to compare the relative intra- and inter-examiner reproducibility of 4 different periodontal probes. (1) The Hu-Friedy LL 20 Probe, a manual probe. (2) The Vivacare TPS Probe, a plastic manual probe with a standardised pressure of 0.20 N. (3) The Vine Valley Prober an electronic probe using a standardised pressure of 0.25 N. 4. The Peri Probe Comp, a computerised electronic probe with a controlled pressure of 0.45 N in 2 mm pockets to 0.25 N in 13 mm pockets. Duplicate probing measurements were taken by 2 examiners in 10 patients on 3 index teeth, 1 molar, 1 premolar and 1 incisor at 6 sites per tooth. Teeth were selected to incorporate both shallow (<5 mm) and deeper (greater than or equal to 5 mm) periodontal sites. The order of probes and examiners were changed in a systematic manner and measurements were repeated 1 week later to avoid bias due to examiner memory. Results show that the manual probe had the lowest degree of variation. with a correlation coefficient of 0.83. The manual and Peri Probe Comp frequently recorded deeper probing pocket depths compared to the TPS and Vine Valley probes, The results may have been influenced by the lack of familiarity with the automated probes.
引用
收藏
页码:76 / 82
页数:7
相关论文
共 29 条
  • [11] BLEEDING ON PROBING AS IT RELATES TO PROBING PRESSURE AND GINGIVAL HEALTH IN PATIENTS WITH A REDUCED BUT HEALTHY PERIODONTIUM - A CLINICAL-STUDY
    KARAYIANNIS, A
    LANG, NP
    JOSS, A
    NYMAN, S
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1992, 19 (07) : 471 - 475
  • [12] KRUST K, 1991, Journal of Dental Research, V70, P587
  • [13] BLEEDING ON PROBING AS IT RELATES TO PROBING PRESSURE AND GINGIVAL HEALTH
    LANG, NP
    NYMAN, S
    SENN, C
    JOSS, A
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1991, 18 (04) : 257 - 261
  • [14] PERIODONTAL PROBING AND RELATIONSHIP OF PROBE TIP TO PERIODONTAL TISSUES
    LISTGARTEN, MA
    MAO, R
    ROBINSON, PJ
    [J]. JOURNAL OF PERIODONTOLOGY, 1976, 47 (09) : 511 - 513
  • [15] PERIODONTAL PROBING - WHAT DOES IT MEAN
    LISTGARTEN, MA
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1980, 7 (03) : 165 - 176
  • [16] CORRELATION BETWEEN ELECTRONIC AND VISUAL READINGS OF POCKET DEPTHS WITH A NEWLY DEVELOPED CONSTANT FORCE PROBE
    MAGNUSSON, I
    FULLER, WW
    HEINS, PJ
    RAU, CF
    GIBBS, CH
    MARKS, RG
    CLARK, WB
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1988, 15 (03) : 180 - 184
  • [17] HISTOLOGICAL-EVALUATION OF PROBING DEPTH FOLLOWING PERIODONTAL TREATMENT
    MAGNUSSON, I
    LISTGARTEN, MA
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1980, 7 (01) : 26 - 31
  • [18] COMPARATIVE REPRODUCIBILITY OF PROXIMAL PROBING DEPTH USING ELECTRONIC PRESSURE-CONTROLLED AND HAND PROBING
    MULLALLY, BH
    LINDEN, GJ
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1994, 21 (04) : 284 - 288
  • [19] COMPARISON OF MEASUREMENT VARIABILITY USING A STANDARD AND CONSTANT FORCE PERIODONTAL PROBE
    OSBORN, J
    STOLTENBERG, J
    HUSO, B
    AEPPLI, D
    PIHLSTROM, B
    [J]. JOURNAL OF PERIODONTOLOGY, 1990, 61 (08) : 497 - 503
  • [20] COMPARISON OF MEASUREMENT VARIABILITY IN SUBJECTS WITH MODERATE PERIODONTITIS USING A CONVENTIONAL AND CONSTANT FORCE PERIODONTAL PROBE
    OSBORN, JB
    STOLTENBERG, JL
    HUSO, BA
    AEPPLI, DM
    PIHLSTROM, BL
    [J]. JOURNAL OF PERIODONTOLOGY, 1992, 63 (04) : 283 - 289