Complete percutaneous excision of infiltrating carcinoma at stereotactic breast biopsy: How can tumor size be assessed?

被引:26
作者
Liberman, L
Zakowski, MF
Avery, S
Hudis, C
Morris, EA
Abramson, AF
LaTrenta, LR
Glassman, JR
Dershaw, DD
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Radiol, Breast Imaging Sect, New York, NY 10021 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Pathol, New York, NY 10021 USA
[3] Mem Sloan Kettering Canc Ctr, Dept Med, New York, NY 10021 USA
[4] Mem Sloan Kettering Canc Ctr, Dept Epidemiol & Biostat, New York, NY 10021 USA
关键词
D O I
10.2214/ajr.173.5.10541111
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE, The purpose of this study was to determine the frequency of complete excision of infiltrating carcinoma at stereotactic Ii-gauge directional vacuum-assisted breast biopsy and to evaluate the feasibility of measuring tumor size in stereotactic biopsy specimens in infiltrating carcinomas that were percutaneously excised. MATERIALS AND METHODS. We performed retrospective review of 51 infiltrating carcinomas diagnosed using stereotactic Ii-gauge directional vacuum-assisted biopsy that underwent subsequent surgery. For lesions yielding no residual infiltrating carcinoma at surgery, the maximal dimension of the tumor was measured in stereotactic biopsy specimens using ocular micrometry. RESULTS. In 10 (20%) (95% confidence intervals, 9.8-33.1%) of 51 infiltrating carcinomas diagnosed at stereotactic biopsy surgery revealed no residual infiltrating carcinoma. Complete excision of infiltrating carcinoma was more frequent if 14 or more specimens were obtained (32% versus 0%,p < .004), if the mammographic lesion was removed (35% versus 7%, p < .03), and if the mammographic lesion size measured 0.7 cm or less (50% versus 16%, p = .08). Tumor size in stereotactic biopsy specimens was within 3 mm of mammographic lesion size in six (60%) of 10 lesions, including five (71%) of seven masses and one (33%) of three calcification lesions, but was smaller than the mammographic lesion size in eight (80%) of 10 lesions. CONCLUSION. Surgery revealed no residual infiltrating carcinoma in 10 (20%) of 51 infiltrating carcinomas diagnosed at stereotactic 11-gauge biopsy. Although tumor size can be assessed in stereotactic biopsy specimens in these lesions, such measurements may underestimate the maximal dimension of the tumor. Further study is needed to evaluate the usefulness of these measurements in guiding treatment decisions.
引用
收藏
页码:1315 / 1322
页数:8
相关论文
共 37 条
[1]  
Abner AL, 1998, CANCER-AM CANCER SOC, V83, P2502, DOI 10.1002/(SICI)1097-0142(19981215)83:12<2502::AID-CNCR14>3.3.CO
[2]  
2-9
[3]  
[Anonymous], 1991, PRACTICAL STAT MED R
[4]  
[Anonymous], [No title captured]
[5]  
Berezowski K, 1997, MODERN PATHOL, V10, p16A
[6]   Ultrasound in breast carcinoma: what are we looking at? A sonographic/pathological correlation [J].
Blunt, DM ;
Sansom, HE ;
Nasiri, N ;
Moskovic, EC .
BREAST, 1998, 7 (03) :156-161
[7]   BREAST-TUMORS - COMPARATIVE ACCURACY OF MR-IMAGING RELATIVE TO MAMMOGRAPHY AND US FOR DEMONSTRATING EXTENT [J].
BOETES, C ;
MUS, RDM ;
HOLLAND, R ;
BARENTSZ, JO ;
STRIJK, SP ;
WOBBES, T ;
HENDRIKS, JHCL ;
RUYS, SHJ .
RADIOLOGY, 1995, 197 (03) :743-747
[8]   Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: Improved accuracy with directional, vacuum-assisted biopsy [J].
Burbank, F .
RADIOLOGY, 1997, 202 (03) :843-847
[9]   Tissue marking clip for stereotactic breast biopsy: Initial placement accuracy, long-term stability, and usefulness as a guide for wire localization [J].
Burbank, F ;
Forcier, N .
RADIOLOGY, 1997, 205 (02) :407-415
[10]   Breast cancer measurements with magnetic resonance imaging, ultrasonography, and mammography [J].
Davis, PL ;
Staiger, MJ ;
Harris, KB ;
Ganott, MA ;
Klementaviciene, J ;
McCarthy, KS ;
Tobon, H .
BREAST CANCER RESEARCH AND TREATMENT, 1996, 37 (01) :1-9