The realization of an integrated Mach-Zehnder waveguide immunosensor in silicon technology

被引:87
作者
Schipper, EF
Brugman, AM
Dominguez, C
Lechuga, LM
Kooyman, RPH
Greve, J
机构
[1] CTR NACL MICROELECT,BELLATERRA 08193,BARCELONA,SPAIN
[2] CTR NACL MICROELECT,MADRID 28006,SPAIN
关键词
immunosensors; Mach-Zehnder principle; evanescent waves; channel waveguides;
D O I
10.1016/S0925-4005(97)80254-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe the realization of a symmetric integrated channel waveguide Mach-Zehnder sensor which uses the evanescent field to detect small refractive-index changes (Delta n(min) approximate to 1 x 10(-4)) near the guiding-layer surface. This guiding layer consists of ridge structures with a height of 3 nm and a width of 4 mu m made in Si3N4. This layer has a thickness of 100 nm. The sensor device has been tested with glucose solutions of different bulk refractive indices. Results of a slab-model calculation are in good agreement with obtained experimental results. The feasibility of applying this sensor for immunosensing, detecting directly the binding of antigen to an antibody receptor surface, is shown with antibody-antigen binding experiments. (C) 1997 Elsevier Science S.A.
引用
收藏
页码:147 / 153
页数:7
相关论文
共 9 条
[1]   INTEGRATED OPTICAL GAS SENSORS USING ORGANICALLY MODIFIED SILICATES AS SENSITIVE FILMS [J].
BRANDENBURG, A ;
EDELHAUSER, R ;
HUTTER, F .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 11 (1-3) :361-374
[2]   A GAS SENSOR BASED ON AN INTEGRATED OPTICAL MACH-ZEHNDER INTERFEROMETER [J].
FABRICIUS, N ;
GAUGLITZ, G ;
INGENHOFF, J .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 7 (1-3) :672-676
[3]   PERFORMANCE OF A HIGHLY SENSITIVE OPTICAL WAVE-GUIDE MACH-ZEHNDER INTERFEROMETER IMMUNOSENSOR [J].
HEIDEMAN, RG ;
KOOYMAN, RPH ;
GREVE, J .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 10 (03) :209-217
[5]   The critical sensor: A new type of evanescent wave immunosensor [J].
Schipper, EF ;
Kooyman, RPH ;
Borreman, A ;
Greve, J .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (03) :295-304
[6]   FEASIBILITY OF OPTICAL WAVE-GUIDE IMMUNOSENSORS FOR PESTICIDE DETECTION - PHYSICAL ASPECTS [J].
SCHIPPER, EF ;
KOOYMAN, RPH ;
HEIDEMAN, RG ;
GREVE, J .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) :90-93
[7]   SCATTERING IN PLANAR SURFACE WAVE-GUIDE IMMUNOSENSORS [J].
SLOPER, AN ;
FLANAGAN, MT .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 11 (1-3) :537-542
[8]  
Syms R., 1992, Optical Guided Waves and Devices
[9]   SENSITIVITY OF GRATING COUPLERS AS INTEGRATED-OPTICAL CHEMICAL SENSORS [J].
TIEFENTHALER, K ;
LUKOSZ, W .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1989, 6 (02) :209-220